Kaifeng Liu1, Kouki Nagamune2, Keisuke Oe2, Ryosuke Kuroda2, Takahiro Niikura2. 1. Department of Human and Artificial Intelligent Systems, Graduate School of Engineering, University of Fukui, Fukui 910-8507, Japan. 2. Department of Orthopaedic Surgery, Kobe University Graduate School of Medicine, Kobe 650-0017, Japan.
Abstract
Background and objectives: Internal fixation is one of the most effective methods for the treatment of proximal femur fractures. The migration of implants after the operation can seriously affect the reduction of treatment and even cause complications. Traditional diagnosis methods can not directly measure the extent of displacement. Methods: Based on the analysis of Hansson pins, this paper proposes a measurement method based on three-dimensional matching, which uses computerized tomography (CT) images of different periods of patients after the operation to analyze the implants' migration in three-dimensional space with the characteristics of fast speed and intuitive results. Results and conclusions: The measurement results show that the method proposed in this paper has more minor errors, more flexible coordinate system conversion, and more explicit displacement analysis than the traditional method of manually finding references in CT images and measuring displacement.
Background and objectives: Internal fixation is one of the most effective methods for the treatment of proximal femur fractures. The migration of implants after the operation can seriously affect the reduction of treatment and even cause complications. Traditional diagnosis methods can not directly measure the extent of displacement. Methods: Based on the analysis of Hansson pins, this paper proposes a measurement method based on three-dimensional matching, which uses computerized tomography (CT) images of different periods of patients after the operation to analyze the implants' migration in three-dimensional space with the characteristics of fast speed and intuitive results. Results and conclusions: The measurement results show that the method proposed in this paper has more minor errors, more flexible coordinate system conversion, and more explicit displacement analysis than the traditional method of manually finding references in CT images and measuring displacement.
Entities:
Keywords:
3D matching; CT images; internal fixation; migration of implants; proximal femur fractures
Authors: John T Richards; Archie L Overmann; Nathan N O'Hara; Jean-Claude D'Alleyrand; Gerard P Slobogean Journal: J Orthop Trauma Date: 2020-01 Impact factor: 2.512
Authors: Kristine Kalland; Henrik Åberg; Anna Berggren; Michael Ullman; Greta Snellman; Kenneth B Jonsson; Torsten Johansson Journal: Acta Orthop Date: 2019-08-27 Impact factor: 3.717
Authors: Henrique Mansur; Rafael Alvarez; Anderson Freitas; Cesar Barbosa Gonçalves; Max Rogerio Freitas Ramos Journal: Acta Ortop Bras Date: 2018 May-Jun Impact factor: 0.513