Literature DB >> 22088443

Design of a hybrid double-sideband/single-sideband (schlieren) objective aperture suitable for electron microscopy.

Bart Buijsse1, Frank M H M van Laarhoven, Andreas K Schmid, Rossana Cambie, Stefano Cabrini, Jian Jin, Robert M Glaeser.   

Abstract

A novel design is described for an aperture that blocks a half-plane of the electron diffraction pattern out to a desired scattering angle, and then--except for a narrow support beam--transmits all of the scattered electrons beyond that angle. Our proposed tulip-shaped design is thus a hybrid between the single-sideband (ssb) aperture, which blocks a full half-plane of the diffraction pattern, and the conventional (i.e. fully open) double-sideband (dsb) aperture. The benefits of this hybrid design include the fact that such an aperture allows one to obtain high-contrast images of weak-phase objects with the objective lens set to Scherzer defocus. We further demonstrate that such apertures can be fabricated from thin-foil materials by milling with a focused ion beam (FIB), and that such apertures are fully compatible with the requirements of imaging out to a resolution of at least 0.34nm. As is known from earlier work with single-sideband apertures, however, the edge of such an aperture can introduce unwanted, electrostatic phase shifts due to charging. The principal requirement for using such an aperture in a routine data-collection mode is thus to discover appropriate materials, protocols for fabrication and processing and conditions of use such that the hybrid aperture remains free of charging over long periods of time.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 22088443      PMCID: PMC3226868          DOI: 10.1016/j.ultramic.2011.09.015

Source DB:  PubMed          Journal:  Ultramicroscopy        ISSN: 0304-3991            Impact factor:   2.689


  14 in total

1.  Retrofit implementation of Zernike phase plate imaging for cryo-TEM.

Authors:  Michael Marko; Ardean Leith; Chyongere Hsieh; Radostin Danev
Journal:  J Struct Biol       Date:  2011-01-25       Impact factor: 2.867

2.  How I discovered phase contrast.

Authors:  F ZERNIKE
Journal:  Science       Date:  1955-03-11       Impact factor: 47.728

Review 3.  Precise beam-tilt alignment and collimation are required to minimize the phase error associated with coma in high-resolution cryo-EM.

Authors:  Robert M Glaeser; Dieter Typke; Peter C Tiemeijer; James Pulokas; Anchi Cheng
Journal:  J Struct Biol       Date:  2010-12-21       Impact factor: 2.867

Review 4.  Development of phase plates for electron microscopes and their biological application.

Authors:  Kuniaki Nagayama
Journal:  Eur Biophys J       Date:  2008-02-08       Impact factor: 1.733

Review 5.  Retrospective on the early development of cryoelectron microscopy of macromolecules and a prospective on opportunities for the future.

Authors:  Kenneth A Taylor; Robert M Glaeser
Journal:  J Struct Biol       Date:  2008-06-19       Impact factor: 2.867

6.  Optimizing the phase shift and the cut-on periodicity of phase plates for TEM.

Authors:  Radostin Danev; Kuniaki Nagayama
Journal:  Ultramicroscopy       Date:  2011-04-30       Impact factor: 2.689

7.  Electron microscopy of the stacked disk aggregate of tobacco mosaic virus protein. I. Three-dimensional image reconstruction.

Authors:  P N Unwin; A Klug
Journal:  J Mol Biol       Date:  1974-08-25       Impact factor: 5.469

8.  Practical factors affecting the performance of a thin-film phase plate for transmission electron microscopy.

Authors:  Radostin Danev; Robert M Glaeser; Kuniaki Nagayama
Journal:  Ultramicroscopy       Date:  2008-12-11       Impact factor: 2.689

9.  Accurate modeling of single-particle cryo-EM images quantitates the benefits expected from using Zernike phase contrast.

Authors:  R J Hall; E Nogales; R M Glaeser
Journal:  J Struct Biol       Date:  2011-04-02       Impact factor: 2.867

10.  Zernike phase contrast cryo-electron tomography.

Authors:  Radostin Danev; Shuji Kanamaru; Michael Marko; Kuniaki Nagayama
Journal:  J Struct Biol       Date:  2010-03-27       Impact factor: 2.867

View more
  4 in total

1.  Methods for testing Zernike phase plates and a report on silicon-based phase plates with reduced charging and improved ageing characteristics.

Authors:  Michael Marko; Xing Meng; Chyongere Hsieh; James Roussie; Christopher Striemer
Journal:  J Struct Biol       Date:  2013-08-28       Impact factor: 2.867

Review 2.  Invited review article: Methods for imaging weak-phase objects in electron microscopy.

Authors:  Robert M Glaeser
Journal:  Rev Sci Instrum       Date:  2013-11       Impact factor: 1.523

3.  Volta potential phase plate for in-focus phase contrast transmission electron microscopy.

Authors:  Radostin Danev; Bart Buijsse; Maryam Khoshouei; Jürgen M Plitzko; Wolfgang Baumeister
Journal:  Proc Natl Acad Sci U S A       Date:  2014-10-20       Impact factor: 11.205

4.  Minimizing electrostatic charging of an aperture used to produce in-focus phase contrast in the TEM.

Authors:  Robert M Glaeser; Simone Sassolini; Rossana Cambie; Jian Jin; Stefano Cabrini; Andreas K Schmid; Radostin Danev; Bart Buijsse; Roseann Csencsits; Kenneth H Downing; David M Larson; Dieter Typke; B G Han
Journal:  Ultramicroscopy       Date:  2013-06-08       Impact factor: 2.689

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.