Literature DB >> 22079769

Inferior tilt of the glenoid component does not decrease scapular notching in reverse shoulder arthroplasty: results of a prospective randomized study.

T Bradley Edwards1, George J Trappey, Clayton Riley, Daniel P O'Connor, Hussein A Elkousy, Gary M Gartsman.   

Abstract

HYPOTHESIS: The purpose of this study was to determine if inferior tilt of the glenoid component decreased the amount of radiographic scapular notching after reverse shoulder arthroplasty. A secondary goal was to determine if inferior tilt had any effect on clinical outcome.
MATERIALS AND METHODS: A prospective randomized trial of 52 consecutive reverse shoulder arthroplasties performed by 1 surgeon for cuff tear arthropathy was performed. The subjects were randomly assigned to receive a glenoid component with no inferior tilt (control group) or a glenoid component that was inferiorly tilted 10° to protect the inferior glenoid (inferior tilt group). All glenoid components were placed in 3 mm of inferior translation. Radiographic notching was graded at a minimum of 1 year after surgery. Clinical outcomes of the groups were recorded.
RESULTS: Follow-up radiographs and data were available for 42 subjects, 20 in the inferior tilt group and 22 in the control group. The experimental groups did not differ significantly in the notch ratings or clinical outcomes. Notching occurred in 15 patients (75%) in the inferior tilt group and in 19 (86%) in the control group. Notching scores were 2 or greater in 10 patients (50%) in the inferior tilt group and in 11 (50%) in the control group.
CONCLUSION: Placing the glenoid component with inferior tilt does not reduce the incidence or severity of radiographic scapular notching after reverse shoulder arthroplasty. No clinical differences were observed between the groups.
Copyright © 2012 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 22079769     DOI: 10.1016/j.jse.2011.08.057

Source DB:  PubMed          Journal:  J Shoulder Elbow Surg        ISSN: 1058-2746            Impact factor:   3.019


  20 in total

Review 1.  Reverse polarity shoulder replacement: Current concepts and review of literature.

Authors:  Ling Hong Lee; Aravind Desai
Journal:  World J Orthop       Date:  2014-07-18

2.  Clinical and radiological outcome of the Total Evolutive Shoulder System (TESS®) reverse shoulder arthroplasty: a prospective comparative non-randomised study.

Authors:  Bakir Kadum; Sebastian Mukka; Erling Englund; Arkan Sayed-Noor; Göran Sjödén
Journal:  Int Orthop       Date:  2014-01-24       Impact factor: 3.075

Review 3.  Reverse Total Shoulder Arthroplasty: Biomechanics and Indications.

Authors:  Caitlin M Rugg; Monica J Coughlan; Drew A Lansdown
Journal:  Curr Rev Musculoskelet Med       Date:  2019-12

4.  Augmented reality through head-mounted display for navigation of baseplate component placement in reverse total shoulder arthroplasty: a cadaveric study.

Authors:  Philipp Kriechling; Rafael Loucas; Marios Loucas; Fabio Casari; Philipp Fürnstahl; Karl Wieser
Journal:  Arch Orthop Trauma Surg       Date:  2021-07-02       Impact factor: 3.067

Review 5.  Going forward with reverse shoulder arthroplasty.

Authors:  Keshav Singhal
Journal:  J Clin Orthop Trauma       Date:  2017-10-06

Review 6.  Reverse Total Shoulder Arthroplasty: Implant Design Considerations.

Authors:  Ujash Sheth; Matthew Saltzman
Journal:  Curr Rev Musculoskelet Med       Date:  2019-12

7.  Superior Baseplate Inclination Is Associated With Instability After Reverse Total Shoulder Arthroplasty.

Authors:  Robert Z Tashjian; Brook I Martin; Cassandra A Ricketts; Heath B Henninger; Erin K Granger; Peter N Chalmers
Journal:  Clin Orthop Relat Res       Date:  2018-08       Impact factor: 4.176

8.  Does lateralisation of the centre of rotation in reverse shoulder arthroplasty avoid scapular notching? Clinical and radiological review of one hundred and forty cases with forty five months of follow-up.

Authors:  Denis Katz; Philippe Valenti; Jean Kany; Kamil Elkholti; Jean-David Werthel
Journal:  Int Orthop       Date:  2015-09-04       Impact factor: 3.075

9.  Computer-Assisted Surgery in Reverse Shoulder Arthroplasty: Early Experience.

Authors:  Andrea Giorgini; Luigi Tarallo; Michele Novi; Giuseppe Porcellini
Journal:  Indian J Orthop       Date:  2021-01-27       Impact factor: 1.251

10.  The glenoid-intramedullary humeral angle: a measurement of compensatory scapular abduction in advanced rotator cuff arthropathy and its potential effects on implant choice.

Authors:  Christopher M Loftis; Devin St Clair; James L Cook; Daniel S Robertson; Robert C Reams; Matthew J Smith
Journal:  JSES Int       Date:  2021-04-09