Literature DB >> 22074866

Digital subtraction radiography evaluation of longitudinal bone density changes around immediate loading implants: a pilot study.

L S Carneiro1, H A da Cunha, C R Leles, E F Mendonça.   

Abstract

OBJECTIVE: The aim of this study was to assess longitudinal quantitative changes in bone density around different implant loading protocols and implant surfaces measured by digital subtraction radiography (DSR).
METHODS: 12 patients received bilateral homologous standard and TiUnite® (Nobel Biocare, Kloten, Switzerland) single-tooth implants under 2 implant-loading protocols: immediate loading (8 patients, 16 implants, 12 maxillary) and conventional loading (4 patients, 8 implants, 4 maxillary). Standardized periapical radiographs were taken immediately after implant placement (baseline image) and at the 3-month, 6-month and 12-month follow ups. Radiographic images were digitized and submitted to digital subtraction using the DSR system® (Electro Medical System, Nyon, Switzerland), resulting in three subtracted images. Quantitative analysis of bone density was performed using Image Tool® software (University of Texas Health Science Centre, San Antonio, TX) to assess pixel value changes in five areas around the implants (crestal, subcrestal, medial third, apical-lateral and apical).
RESULTS: Repeated-measures analysis of variance showed that grey levels were significantly influenced by follow-up time and implant-loading protocol. A linear increase in grey levels was found for immediate loading (IML) implants and a significant decrease in grey levels was observed in the 12-month follow up for conventional loading implants. No effect of implant surface treatment was observed.
CONCLUSION: In conclusion, IML protocol induced mineral bone gain around single-tooth implants after the first year under function for cases with favourable bone conditions.

Entities:  

Mesh:

Year:  2011        PMID: 22074866      PMCID: PMC3520294          DOI: 10.1259/dmfr/89401091

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  27 in total

1.  Crestal bone changes around titanium implants. A histometric evaluation of unloaded non-submerged and submerged implants in the canine mandible.

Authors:  J S Hermann; D Buser; R K Schenk; D L Cochran
Journal:  J Periodontol       Date:  2000-09       Impact factor: 6.993

2.  Bone-implant interface around titanium implants under different loading conditions: a histomorphometrical analysis in the Macaca fascicularis monkey.

Authors:  George E Romanos; Chooi Gait Toh; Chong Huat Siar; Helmut Wicht; Hashim Yacoob; Georg-Hubertus Nentwig
Journal:  J Periodontol       Date:  2003-10       Impact factor: 6.993

3.  Initial implant position determines the magnitude of crestal bone remodeling.

Authors:  Gary A Hartman; David L Cochran
Journal:  J Periodontol       Date:  2004-04       Impact factor: 6.993

4.  Variations in bone density at dental implant sites in different regions of the jawbone.

Authors:  L-J Fuh; H-L Huang; C-S Chen; K-L Fu; Y-W Shen; M-G Tu; W-C Shen; J-T Hsu
Journal:  J Oral Rehabil       Date:  2010-01-25       Impact factor: 3.837

5.  Immediate loading of titanium plasma-sprayed screw-shaped implants in man: a clinical and histological report of two cases.

Authors:  A Piattelli; M Paolantonio; M Corigliano; A Scarano
Journal:  J Periodontol       Date:  1997-06       Impact factor: 6.993

6.  Immediate loading of titanium plasma-sprayed implants: an histologic analysis in monkeys.

Authors:  A Piattelli; M Corigliano; A Scarano; G Costigliola; M Paolantonio
Journal:  J Periodontol       Date:  1998-03       Impact factor: 6.993

7.  Digital subtraction radiography for longitudinal assessment of peri-implant bone change: method and validation.

Authors:  M K Jeffcoat; M S Reddy
Journal:  Adv Dent Res       Date:  1993-08

8.  Radiographic bone density around immediately loaded oral implants.

Authors:  Antonio Barone; Ugo Covani; Roberto Cornelini; Enrico Gherlone
Journal:  Clin Oral Implants Res       Date:  2003-10       Impact factor: 5.977

9.  Histologic evaluation of bone response to oxidized and turned titanium micro-implants in human jawbone.

Authors:  Carl-Johan Ivanoff; Göran Widmark; Carina Johansson; Ann Wennerberg
Journal:  Int J Oral Maxillofac Implants       Date:  2003 May-Jun       Impact factor: 2.804

10.  Bone response to loaded implants with non-matching implant-abutment diameters in the canine mandible.

Authors:  David L Cochran; Dieter D Bosshardt; Leticia Grize; Frank L Higginbottom; Archie A Jones; Ronald E Jung; Marco Wieland; Michel Dard
Journal:  J Periodontol       Date:  2009-04       Impact factor: 6.993

View more
  2 in total

1.  Evaluation of cervical peri-implant optical density in longitudinal control of immediate implants in the anterior maxilla region.

Authors:  Renan Lucio Berbel da Silva; Eduardo Felippe Duailibi Neto; Franscisco Fernando Todescan; Glaucio Morente Ruiz; Claudio Mendes Pannuti; Israel Chilvarquer
Journal:  Dentomaxillofac Radiol       Date:  2020-05-27       Impact factor: 2.419

2.  Exposure time reduction of secondary radiographs used in digital subtraction radiography in detecting intrabony change.

Authors:  Yukiko Matsuda; Tsuneyasu Terauchi; Kota Murahira; Seema Patil; Vajendra Joshi; Kazuyuki Araki; Akira Taguchi; Tomohiro Okano
Journal:  Oral Radiol       Date:  2013-04-04       Impact factor: 1.852

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.