Literature DB >> 32364770

Evaluation of cervical peri-implant optical density in longitudinal control of immediate implants in the anterior maxilla region.

Renan Lucio Berbel da Silva1, Eduardo Felippe Duailibi Neto2, Franscisco Fernando Todescan2, Glaucio Morente Ruiz2, Claudio Mendes Pannuti1, Israel Chilvarquer1.   

Abstract

OBJECTIVE: This research aimed to longitudinally evaluate the optical density of peri-implant alveolar bone. The data acquired from study participants previously treated with 37 osseointegrated implants were analyzed utilizing the radiographic subtraction technique. METHODS AND MATERIALS: The radiographic follow-ups were performed five times: at the implantation of the prostheses and after 15, 90, 180 and 360 days. Intraoral radiographs were obtained by the paralleling technique using individualized Hanshin-type positioners to guarantee the standardization of the images. The obtained digital images were aligned and equalized before they were submitted to the radiographic subtraction procedure.
RESULTS: A significant difference was found between the distal region of Group I (patients treated with osseointegrated implants who required extraction of the dental element) and the 360 day follow-up and the distal region of Group II (patients with healed alveolar sockets) in all follow-up analyses (p < 0.05). We did not observe a significant difference between the groups analyzed and other follow-ups concerning the subcrestal and middle third regions for both the mesial and distal variables (p > 0.05). There was a statistically significant difference in the distal sites [χ2 = 5,745,, p = 0.03], showing a significant association between time and the presence of bone resorption. This association was not shown on the mesial surface (p = 0.16).
CONCLUSION: We concluded that there was no statistically significant difference between groups I and II. Using this technique, we were able to quantitatively and qualitatively evaluate the changes in the proximal sites on the digital radiographic images for the analyzed data. Digital subtraction technology to measure peri-implant bone density is an accurate and reproducible technique for quantifying peri-implant bone reactions to different therapeutic modalities.

Entities:  

Keywords:  Osseointegration; Optical density; Radiographic subtraction

Mesh:

Substances:

Year:  2020        PMID: 32364770      PMCID: PMC7461732          DOI: 10.1259/dmfr.20190396

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  24 in total

1.  Digital subtraction radiography evaluation of longitudinal bone density changes around immediate loading implants: a pilot study.

Authors:  L S Carneiro; H A da Cunha; C R Leles; E F Mendonça
Journal:  Dentomaxillofac Radiol       Date:  2011-11-10       Impact factor: 2.419

2.  A comparison of cone beam computed tomography and conventional periapical radiography at detecting peri-implant bone defects.

Authors:  Meetal Dave; Jonathan Davies; Ron Wilson; Richard Palmer
Journal:  Clin Oral Implants Res       Date:  2012-03-27       Impact factor: 5.977

3.  A comparison of endosseous dental implant surfaces.

Authors:  D L Cochran
Journal:  J Periodontol       Date:  1999-12       Impact factor: 6.993

4.  A radiographic assessment of progressive loading on bone around single osseointegrated implants in the posterior maxilla.

Authors:  Richard S Appleton; Pirkka V Nummikoski; Mark A Pigno; Robert J Cronin; Kwok-Hung Chung
Journal:  Clin Oral Implants Res       Date:  2005-04       Impact factor: 5.977

5.  Digital subtraction technique for evaluation of peri-implant bone change in digital dental imaging.

Authors:  Mamoru Wakoh; Keiichi Nishikawa; Takamichi Otonari; Mika Yamamoto; Takuya Harada; Tsukasa Sano; Yasutomo Yajima; Toshiki Ooguro
Journal:  Bull Tokyo Dent Coll       Date:  2006-05

Review 6.  Criteria for success of osseointegrated endosseous implants.

Authors:  D E Smith; G A Zarb
Journal:  J Prosthet Dent       Date:  1989-11       Impact factor: 3.426

7.  A 15-year study of osseointegrated implants in the treatment of the edentulous jaw.

Authors:  R Adell; U Lekholm; B Rockler; P I Brånemark
Journal:  Int J Oral Surg       Date:  1981-12

8.  Radiographic evaluation of osseointegrated implants of the jaws. Experimental study of the influence of radiographic techniques on the measurement of the relation between the implant and bone.

Authors:  L Hollender; B Rockler
Journal:  Dentomaxillofac Radiol       Date:  1980       Impact factor: 2.419

9.  Reconstruction of severely resorbed edentulous maxillae using osseointegrated fixtures in immediate autogenous bone grafts.

Authors:  R Adell; U Lekholm; K Gröndahl; P I Brånemark; J Lindström; M Jacobsson
Journal:  Int J Oral Maxillofac Implants       Date:  1990       Impact factor: 2.804

10.  Accuracy of digital subtraction radiography in combination with a contrast media in assessment of proximal caries depth.

Authors:  Solmaz Valizadeh; Sara Ehsani; Farzad Esmaeili; Mohammad Amin Tavakoli
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2008-12-20
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.