Literature DB >> 9203103

Immediate loading of titanium plasma-sprayed screw-shaped implants in man: a clinical and histological report of two cases.

A Piattelli1, M Paolantonio, M Corigliano, A Scarano.   

Abstract

THIS STUDY REPORTS ON THE histological findings of two immediately loaded titanium plasma-sprayed (TPS) implants, retrieved for a fracture of the abutment and for psychological reasons, after 8 and 9 months of loading, respectively. The microscopical analysis showed that mature, compact, cortical bone was present around both implants, with the bone implant contact percentage about 60 to 70%. No fibrous tissue or gaps were present at the interface. No resorption was present in the peri-implant bone. On both implants a few osteoblasts were found positive at the interface for alkaline phosphatase (ALP); while no cells positive for acid phosphatase (ACP) were present. Immediate loading can, perhaps, be used in very selected cases of good bone quality, with implants that have certain macro- (screw shape) and micro-interlocks (titanium plasma-sprayed surface) characteristics. Good results have been reported also for non-TPS surface (e.g., machined surface). More data about different designs (e.g., cylinders) or coatings (e.g., hydroxyapatite) are needed before any firm conclusions about immediate loading can be reached.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9203103     DOI: 10.1902/jop.1997.68.6.591

Source DB:  PubMed          Journal:  J Periodontol        ISSN: 0022-3492            Impact factor:   6.993


  4 in total

1.  Digital subtraction radiography evaluation of longitudinal bone density changes around immediate loading implants: a pilot study.

Authors:  L S Carneiro; H A da Cunha; C R Leles; E F Mendonça
Journal:  Dentomaxillofac Radiol       Date:  2011-11-10       Impact factor: 2.419

2.  Comparative study of immediate functional loading and immediate non-functional loading of monocortical implants.

Authors:  J P Singh; A K Gupta; R K Dhiman; S K Roy Chowdhury
Journal:  Med J Armed Forces India       Date:  2014-03-12

3.  Clinical evaluation of small diameter straumann implants in partially edentulous patients: a 5-year retrospective study.

Authors:  M Yaltirik; B Gökçen-Röhlig; S Ozer; G Evlioglu
Journal:  J Dent (Tehran)       Date:  2011-06-30

4.  Immediate provisionalization and nonfunctional loading of a single implant in the maxillary esthetic zone: a clinical presentation and parameters for consideration.

Authors:  Konstantinos X Michalakis; Christos D R Kalpidis; Yvone Kirmanidou; Hiroshi Hirayama; Pasquale Lino Calvani; Argiris L Pissiotis
Journal:  Case Rep Dent       Date:  2013-12-08
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.