Literature DB >> 22064731

Accuracy of the skyline view for detecting dorsal cortical penetration during volar distal radius fixation.

A P Riddick1, B Hickey, S P White.   

Abstract

Fractures of the distal radius are commonly treated using volar locking plates. Several complications have been associated with this procedure, including extensor tendon irritation and rupture. It has been suggested that prominence of screws past the dorsal cortex may contribute to this complication. This study aimed to determine the ability of the skyline view to demonstrate screws penetrating the dorsal cortex. A volar locking plate was applied to a synthetic forearm model. Lateral, oblique, and skyline views were obtained, with the distal screws both beneath and 1 mm beyond the dorsal cortex. The images were shown to orthopaedic trainees who were asked to decide if screws penetrated the dorsal cortex. Subjects were correct in 83% of cases using the skyline view compared with 77% (p = 0.05, lateral) and 50% (p < 0.01, oblique). This study demonstrates the skyline view of the distal radius could be a useful and accurate addition to routine intraoperative fluoroscopy views.

Entities:  

Mesh:

Year:  2011        PMID: 22064731     DOI: 10.1177/1753193411426809

Source DB:  PubMed          Journal:  J Hand Surg Eur Vol        ISSN: 0266-7681


  12 in total

1.  The utility of the fluoroscopic skyline view during volar locking plate fixation of distal radius fractures.

Authors:  Lucile Vaiss; Satoshi Ichihara; Sarah Hendriks; Chihab Taleb; Philippe Liverneaux; Sybille Facca
Journal:  J Wrist Surg       Date:  2014-11

2.  Detections of Screw Penetration during Volar Plating for Distal Radius Fractures.

Authors:  Soo Min Cha; Hyun Dae Shin
Journal:  J Wrist Surg       Date:  2017-06-02

3.  Volar locking plate fixation of distal radius fractures: use of an intra-operative 'carpal shoot through' view to identify dorsal compartment and distal radioulnar joint screw penetration.

Authors:  Daniel Marsland; Chris M Hobbs; Philip S Sauvé
Journal:  Hand (N Y)       Date:  2014-12

4.  A comparative study about ionizing radiation emitted during radiological "skyline" view of the wrist in pronation versus supination.

Authors:  Lucile Vaiss; Satoshi Ichihara; Dallan Geller Hernandez Ramirez; Sarah Hendriks; Philippe Liverneaux; Sybille Facca
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-06-27

5.  Sensitivity and Specificity of Skyline and Carpal Shoot-Through Fluoroscopic Views of Volar Plate Fixation of the Distal Radius: A Cadaveric Investigation of Dorsal Cortex Screw Penetration.

Authors:  T Kyle Stoops; Brandon G Santoni; Nicolette M Clark; Amy A Bauer; Christopher Shoji; Francisco Schwartz-Fernandes
Journal:  Hand (N Y)       Date:  2016-11-01

6.  Volar Locking Plate Fixations for Displaced Distal Radius Fractures: An Evaluation of Complications and Radiographic Outcomes.

Authors:  James Wilson; Jeremy J Viner; Kavan S Johal; Michael J Woodruff
Journal:  Hand (N Y)       Date:  2017-07-09

Review 7.  [Distal radius fracture of the adult : Diagnostics and therapy].

Authors:  F Unglaub; M F Langer; B Hohendorff; L P Müller; J M Unglaub; P Hahn; H Krimmer; C K Spies
Journal:  Orthopade       Date:  2017-01       Impact factor: 1.087

Review 8.  [Secondary tendon reconstruction on the thumb].

Authors:  B Bickert; T Kremer; U Kneser
Journal:  Unfallchirurg       Date:  2016-12       Impact factor: 1.000

9.  Distal radius fluoroscopic skyline view: extension-supination versus flexion-supination.

Authors:  Laëla El Amiri; Yuka Igeta; Chiara Pizza; Sybille Facca; Juan José Hidalgo Diaz; Liverneaux Philippe
Journal:  Eur J Orthop Surg Traumatol       Date:  2018-10-29

10.  Fluoroscopy of the Elbow: A Cadaveric Study Defining New Standard Projections to Visualize Important Anatomical Landmarks.

Authors:  Sebastian A Müller; Lars Adolfsson; Cornelia Baum; Magdalena Müller-Gerbl; Andreas M Müller; Daniel Rikli
Journal:  JB JS Open Access       Date:  2021-05-05