Literature DB >> 30374641

Distal radius fluoroscopic skyline view: extension-supination versus flexion-supination.

Laëla El Amiri1, Yuka Igeta1,2, Chiara Pizza1, Sybille Facca1, Juan José Hidalgo Diaz1, Liverneaux Philippe3,4.   

Abstract

The aim of our study was to compare the vertical fluoroscopic view of the wrist in extension and supination (ES) to the view in flexion and supination (FS) and determine which of the two views allowed the best visualization of four selected anatomical landmarks SDLR (radial styloid, dorsal radius cortex, Lister's tubercle and distal radioulnar joint). Our case series included 50 patients who had suffered a distal radius fracture and undergone an open reduction and internal fixation procedure with a volar locking plate. For each case, two fluoroscopic views were taken: ES (wrist extension and supination) (group I) and FS (wrist flexion and supination) (group II). Ten observers had to recognize the SDLR anatomical landmarks on 100 fluoroscopic skyline views (time 1) and 15 days later (time 2). The rate of recognition of the four anatomical landmarks was 78% in group I and 66% in group II (p < 0.001). The concordance rate of recognition of the four anatomical landmarks was mediocre (κ = 0.411). In conclusion, the vertical fluoroscopic skyline view in wrist extension and supination seems to be the most adequate view to assess the quality of the fracture reduction, the distal radioulnar joint and the length of the screws in open reduction and internal fixation of distal radius fractures with volar locking plates.

Entities:  

Keywords:  Distal radius; Dorsal tangential view; Skyline

Mesh:

Year:  2018        PMID: 30374641     DOI: 10.1007/s00590-018-2335-3

Source DB:  PubMed          Journal:  Eur J Orthop Surg Traumatol        ISSN: 1633-8065


  19 in total

1.  Intraoperative imaging of the distal radioulnar joint using a modified skyline view.

Authors:  G Klammer; M Dietrich; M Farshad; L Iselin; L Nagy; A Schweizer
Journal:  J Hand Surg Am       Date:  2012-02-03       Impact factor: 2.230

2.  Dorsal tangential view of the wrist to detect screw penetration to the dorsal cortex of the distal radius after volar fixed-angle plating.

Authors:  Kagan Ozer; Serdar Toker
Journal:  Hand (N Y)       Date:  2011-01-07

3.  Re: Pichler et al. Computer tomography aided 3D analysis of the distal dorsal radius surface and the effects on volar plate osteosynthesis. J Hand Surg Eur. 2009, 34: 598-602.

Authors:  J Jacob; N R Clay
Journal:  J Hand Surg Eur Vol       Date:  2010-05

4.  A new radiological method to detect dorsally penetrating screws when using volar locking plates in distal radial fractures. The dorsal horizon view.

Authors:  L C Haug; B Glodny; C Deml; M Lutz; R Attal
Journal:  Bone Joint J       Date:  2013-08       Impact factor: 5.082

5.  Computer tomography aided 3D analysis of the distal dorsal radius surface and the effects on volar plate osteosynthesis.

Authors:  W Pichler; G Windisch; G Schaffler; R Rienmüller; W Grechenig
Journal:  J Hand Surg Eur Vol       Date:  2009-10

6.  The dorsal tangential X-ray view to determine dorsal screw penetration during volar plating of distal radius fractures.

Authors:  Alexander Brunner; Christin Siebert; Claudia Stieger; Alexander Kastius; Björn-Christian Link; Reto Babst
Journal:  J Hand Surg Am       Date:  2014-11-18       Impact factor: 2.230

7.  Detection of penetration of the dorsal cortex by epiphyseal screws of distal radius volar plates: Anatomical study comparing ultrasound and fluoroscopy.

Authors:  P Vernet; A Durry; X Nicolau; A D'Ambrosio; A Collinet; S Botero Salazar; P Liverneaux; J J Hidalgo Diaz
Journal:  Orthop Traumatol Surg Res       Date:  2017-04-15       Impact factor: 2.256

8.  Why and how to report surgeons' levels of expertise.

Authors:  Jin Bo Tang; Grey Giddins
Journal:  J Hand Surg Eur Vol       Date:  2016-05

9.  Two potential causes of EPL rupture after distal radius volar plate fixation.

Authors:  Eric C Benson; Alex DeCarvalho; Elizabeth A Mikola; John M Veitch; Moheb S Moneim
Journal:  Clin Orthop Relat Res       Date:  2006-10       Impact factor: 4.176

10.  Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate.

Authors:  Rohit Arora; Martin Lutz; Alfred Hennerbichler; Dietmar Krappinger; David Espen; Markus Gabl
Journal:  J Orthop Trauma       Date:  2007-05       Impact factor: 2.512

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.