Literature DB >> 25364637

The utility of the fluoroscopic skyline view during volar locking plate fixation of distal radius fractures.

Lucile Vaiss1, Satoshi Ichihara2, Sarah Hendriks1, Chihab Taleb1, Philippe Liverneaux1, Sybille Facca1.   

Abstract

Background Open reduction and internal fixation (ORIF) using a volar locking plate is a common method for treating displaced distal radius fractures. There is, however, the risk of extensor tendon rupture due to protrusion of the screw tips past the dorsal cortex, which cannot always be adequately seen on a lateral fluoroscopic view. We therefore wished to compare the sensitivity of an intraoperative fluoroscopic skyline view to a lateral fluorosocopic view in detecting past pointing of these screws. Material and Methods Our series included 75 patients with an average age of 59 years who underwent volar locked plate fixation of a displaced distal radius fracture. Intraoperative anteroposterior (AP), lateral, and skyline fluoroscopic views were performed in each case. The number of screws that were seen to protrude past the dorsal cortex of the distal fracture fragment were recorded for both the lateral and skyline views. The number of screws that required exchange was also documented. Results No screws were seen to protrude past the dorsal cortical bone on the lateral fluroscopic views. 15 of 300 screws (5%) were seen to protrude past the dorsal cortex by an average of 0.8 mm (range, 0.5 to 2 mm) and were exchanged for shorter screws in 11/75 patients. Conclusion Our results demonstrate that the skyline is more sensitive than a lateral fluoroscopic view at demonstrating protrusion of the screws in the distal fracture fragment following volar locked plate fixation. Level of Evidence IV.

Entities:  

Keywords:  distal radius; screw; skyline; tendon rupture; volar plate

Year:  2014        PMID: 25364637      PMCID: PMC4208954          DOI: 10.1055/s-0034-1394132

Source DB:  PubMed          Journal:  J Wrist Surg        ISSN: 2163-3916


  20 in total

1.  Profiles of the carpal canal.

Authors:  J N WILSON
Journal:  J Bone Joint Surg Am       Date:  1954-01       Impact factor: 5.284

2.  Dorsal tangential view of the wrist to detect screw penetration to the dorsal cortex of the distal radius after volar fixed-angle plating.

Authors:  Kagan Ozer; Serdar Toker
Journal:  Hand (N Y)       Date:  2011-01-07

3.  Re: Pichler et al. Computer tomography aided 3D analysis of the distal dorsal radius surface and the effects on volar plate osteosynthesis. J Hand Surg Eur. 2009, 34: 598-602.

Authors:  J Jacob; N R Clay
Journal:  J Hand Surg Eur Vol       Date:  2010-05

Review 4.  A revolution in the management of fractures of the distal radius?

Authors:  N D Downing; A Karantana
Journal:  J Bone Joint Surg Br       Date:  2008-10

5.  Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report.

Authors:  Jorge L Orbay; Diego L Fernandez
Journal:  J Hand Surg Am       Date:  2002-03       Impact factor: 2.230

6.  A comparative study about ionizing radiation emitted during radiological "skyline" view of the wrist in pronation versus supination.

Authors:  Lucile Vaiss; Satoshi Ichihara; Dallan Geller Hernandez Ramirez; Sarah Hendriks; Philippe Liverneaux; Sybille Facca
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-06-27

7.  Two potential causes of EPL rupture after distal radius volar plate fixation.

Authors:  Eric C Benson; Alex DeCarvalho; Elizabeth A Mikola; John M Veitch; Moheb S Moneim
Journal:  Clin Orthop Relat Res       Date:  2006-10       Impact factor: 4.176

8.  Assessment of complications of distal radius fractures and development of a complication checklist.

Authors:  S D McKay; J C MacDermid; J H Roth; R S Richards
Journal:  J Hand Surg Am       Date:  2001-09       Impact factor: 2.230

9.  Delayed ruptures of the extensor tendon secondary to the use of volar locking compression plates for distal radial fractures.

Authors:  M Al-Rashid; K Theivendran; M A C Craigen
Journal:  J Bone Joint Surg Br       Date:  2006-12

Review 10.  Fracture of the hook of the hamate: radiographic visualization.

Authors:  R E Carroll; J F Lakin
Journal:  Iowa Orthop J       Date:  1993
View more
  2 in total

1.  Anatomical reduction and precise internal fixation of intra-articular fractures of the distal radius with virtual X-ray and 3D printing.

Authors:  Jing Xu; Guodong Zhang; Zaopeng He; Shizhen Zhong; Yongshao Chen; Chunrong Wei; Yudong Zheng; Haibin Lin; Wei Li; Wenhua Huang
Journal:  Australas Phys Eng Sci Med       Date:  2019-10-22       Impact factor: 1.430

2.  Distal radius fluoroscopic skyline view: extension-supination versus flexion-supination.

Authors:  Laëla El Amiri; Yuka Igeta; Chiara Pizza; Sybille Facca; Juan José Hidalgo Diaz; Liverneaux Philippe
Journal:  Eur J Orthop Surg Traumatol       Date:  2018-10-29
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.