Literature DB >> 22053240

Alternate metal framework designs for the metal ceramic prosthesis to enhance the esthetics.

Naina Vilas Vernekar1, Prithviraj Kallahalla Jagadish, Srinivasan Diwakar, Ramesh Nadgir, Manjunatha Revankar Krishnarao.   

Abstract

PURPOSE: The objective of the present study was to evaluate the effect of five different metal framework designs on the fracture resistance of the metal-ceramic restorations.
MATERIALS AND METHODS: For the purpose of this study, the central incisor tooth was prepared, and the metal analogue of it and a master die were fabricated. The counter die with the 0.5 mm clearance was used for fabricating the wax patterns for the metal copings. The metal copings with five different metal framework designs were designed from Group 1 to 5. Group 1 with the metal collar, Group 2, 3, 4 and 5 with 0 mm, 0.5 mm, 1 mm and 1.5 mm cervical metal reduction respectively were fabricated. Total of fifty metal ceramic crown samples were fabricated. The fracture resistance was evaluated with the Universal Testing Machine (Instron model No 1011, UK). The basic data was subjected to statistical analysis by ANOVA and Student's t-test.
RESULTS: Results revealed that the fracture resistance ranged from 651.2 to 993.6 N/m(2). Group 1 showed the maximum and Group 5 showed the least value.
CONCLUSION: The maximum load required to fracture the test specimens even in the groups without the metal collar was found to be exceeding the occlusal forces. Therefore, the metal frameworks with 0.5 mm and 1 mm short of the finish line are recommended for anterior metal ceramic restoration having adequate fracture resistance.

Entities:  

Keywords:  Collarless metal ceramic restoration; Fracture resistance; Metal-ceramic crown

Year:  2011        PMID: 22053240      PMCID: PMC3204445          DOI: 10.4047/jap.2011.3.3.113

Source DB:  PubMed          Journal:  J Adv Prosthodont        ISSN: 2005-7806            Impact factor:   1.904


  25 in total

1.  Thermal cycling distortion of metal ceramics: Part I--Metal collar width.

Authors:  S D Campbell; L B Pelletier
Journal:  J Prosthet Dent       Date:  1992-05       Impact factor: 3.426

2.  Effect of metal design and technique on the marginal characteristics of the collarless metal ceramic restoration.

Authors:  D M Belles; R J Cronin; E S Duke
Journal:  J Prosthet Dent       Date:  1991-05       Impact factor: 3.426

3.  Apparent density and tensile strength of materials for facially butted porcelain margins.

Authors:  R E Hinrichs; W F Bowles; E F Huget
Journal:  J Prosthet Dent       Date:  1990-04       Impact factor: 3.426

4.  Fracture resistance of five different metal framework designs for metal-ceramic restorations.

Authors:  Mübin Ulusoy; Suna Toksavul
Journal:  Int J Prosthodont       Date:  2002 Nov-Dec       Impact factor: 1.681

5.  Calculation of interfacial stress in dental porcelain bonded to gold alloy substrate.

Authors:  J P Nielsen; J J Tuccillo
Journal:  J Dent Res       Date:  1972 Jul-Aug       Impact factor: 6.116

6.  Design and technique variables affecting fracture resistance of metal-ceramic restorations.

Authors:  W S Warpeha; R J Goodkind
Journal:  J Prosthet Dent       Date:  1976-03       Impact factor: 3.426

7.  Occlusal forces during chewing and swallowing as measured by sound transmission.

Authors:  C H Gibbs; P E Mahan; H C Lundeen; K Brehnan; E K Walsh; W B Holbrook
Journal:  J Prosthet Dent       Date:  1981-10       Impact factor: 3.426

8.  In vitro failure load of metal-collar margins compared with porcelain facial margins of metal-ceramic crowns.

Authors:  F M Gardner; K W Tillman-McCombs; M L Gaston; D A Runyan
Journal:  J Prosthet Dent       Date:  1997-07       Impact factor: 3.426

9.  The effect of porcelain veneer extension on strength of metal ceramic crowns.

Authors:  P S Lund; B A Barber
Journal:  Int J Prosthodont       Date:  1992 May-Jun       Impact factor: 1.681

10.  Stress distribution in metal-ceramic crowns with a facial porcelain margin.

Authors:  K J Anusavice; B Hojjatie
Journal:  J Dent Res       Date:  1987-09       Impact factor: 6.116

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.