Literature DB >> 12475164

Fracture resistance of five different metal framework designs for metal-ceramic restorations.

Mübin Ulusoy1, Suna Toksavul.   

Abstract

PURPOSE: This study evaluated fracture resistance of five different metal framework designs for metal-ceramic restorations.
MATERIALS AND METHODS: Twenty-five artificial crowns were fabricated with different degrees of facial metal reduction: metal collar (group 1), and 0, 0.5, 1, and 1.5 mm (groups 2 to 5, respectively). All of the crowns were thermocycled in two different baths of 5 and 60 degrees C for 20 seconds and had a dwell time of 10 seconds in a resting bath at 37 degrees C for 510 cycles. The artificial crowns were then subjected to vertical loading until fracture with a Shimadzu testing machine at a cross-head speed of 1 mm/min. The load at fracture was recorded.
RESULTS: There were no statistically significant differences between mean fracture strength of groups 1 and 2 or between groups 4 and 5. There were significant differences between group 3 and groups 1, 2, 4, and 5.
CONCLUSION: As the amount of metal reduction increased, the vertical fracture resistance decreased. Failure loads for all test groups exceeded normal biting forces.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12475164

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  5 in total

1.  Alternate metal framework designs for the metal ceramic prosthesis to enhance the esthetics.

Authors:  Naina Vilas Vernekar; Prithviraj Kallahalla Jagadish; Srinivasan Diwakar; Ramesh Nadgir; Manjunatha Revankar Krishnarao
Journal:  J Adv Prosthodont       Date:  2011-09-25       Impact factor: 1.904

2.  A study on the fracture strength of collarless metal-ceramic fixed partial dentures.

Authors:  Jong-Wook Yoon; Sung-Hun Kim; Jai-Bong Lee; Jung-Suk Han; Jae-Ho Yang
Journal:  J Adv Prosthodont       Date:  2010-12-31       Impact factor: 1.904

3.  Marginal strength of collarless metal ceramic crown.

Authors:  Sikka Swati; R Chowdhary; P S Patil
Journal:  Int J Dent       Date:  2010-06-01

4.  The influence of various core designs on stress distribution in the veneered zirconia crown: a finite element analysis study.

Authors:  Seung-Ryong Ha; Sung-Hun Kim; Jung-Suk Han; Seung-Hyun Yoo; Se-Chul Jeong; Jai-Bong Lee; In-Sung Yeo
Journal:  J Adv Prosthodont       Date:  2013-05-30       Impact factor: 1.904

5.  Disilicate Dental Ceramic Surface Preparation by 1070 nm Fiber Laser: Thermal and Ultrastructural Analysis.

Authors:  Carlo Fornaini; Federica Poli; Elisabetta Merigo; Nathalie Brulat-Bouchard; Ahmed El Gamal; Jean-Paul Rocca; Stefano Selleri; Annamaria Cucinotta
Journal:  Bioengineering (Basel)       Date:  2018-01-31
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.