Stress distribution in metal-ceramic crowns with a facial porcelain margin.

K J Anusavice, B Hojjatie.   

Abstract

The use of metal-ceramic restorations with porcelain butt-joint facial margins has increased in the past several years. Although these crowns exhibit improved esthetics compared with metal-ceramic crowns which display a metal gingival collar or metal knife-edge margin, the effectiveness of this design in resisting intra-oral forces is not known. The objective of this study was to analyze the stress distribution induced by simulated intra-oral loads on crowns with variable coping configurations. The copings, with a thickness of either 0.1 or 0.3 mm, were modeled with a facial termination of metal at three locations: at the gingival floor, 0.9 mm above the gingival floor, and 4.2 mm above the gingival floor. The coping and crown dimensions were based on a prepared maxillary central incisor with a facial shoulder and a lingual chamfer. Both Ni-Cr and Au-Pd alloy copings were employed in the crown models. Finite element stress and analyses were performed on crowns which were subjected to several loading conditions. A cement film thickness of 0.030 mm was assumed. For all cases, the stresses which developed in porcelain and cement near the facial and lingual margins due to a vertical load of 200 N were predominantly compressive in nature. For the crowns with Ni-Cr copings, the tensile stress in porcelain ranged from 11.0 MPa (for crowns with a facial metal thickness of 0.3 mm) to 12.5 MPa (for a metal thickness of 0.1 mm). The corresponding stresses for crowns with Au-Pd alloy copings were 8.3 MPa and 8.6 MPa, respectively.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3305641     DOI: 10.1177/00220345870660091601

Source DB:  PubMed          Journal:  J Dent Res        ISSN: 0022-0345            Impact factor:   6.116


  5 in total

1.  Comparative study of fracture resistance of porcelain in metal ceramic restorations by using different metal coping designs- an in vitro study.

Authors:  Nilesh Bulbule; B K Motwani
Journal:  J Clin Diagn Res       Date:  2014-11-20

2.  Effect of Preparation Taper, Height and Marginal Design Under Varying Occlusal Loading Conditions on Cement Lute Stress: A Three Dimensional Finite Element Analysis.

Authors:  Siddhi Tripathi; Gowdagere Shamanna Amarnath; Byrasandra Channapa Muddugangadhar; Ashish Sharma; Suchismita Choudhary
Journal:  J Indian Prosthodont Soc       Date:  2014-07-10

3.  Alternate metal framework designs for the metal ceramic prosthesis to enhance the esthetics.

Authors:  Naina Vilas Vernekar; Prithviraj Kallahalla Jagadish; Srinivasan Diwakar; Ramesh Nadgir; Manjunatha Revankar Krishnarao
Journal:  J Adv Prosthodont       Date:  2011-09-25       Impact factor: 1.904

4.  Translucency of a Dental Porcelain Mixed by Two Ceramic Slurry Methods: A Bayesian Comparison.

Authors:  Catalina Serna-Meneses; Gabriel Ocampo-Parra; Santiago Arango-Santander; Claudia Garcia-Garcia; Luis Felipe Restrepo-Tamayo; Johnatan Cardona-Jimenez; Alexander Ossa; Alejandro Pelaez-Vargas
Journal:  Int J Dent       Date:  2022-06-06

5.  Splinted and Nonsplinted Crowns with Different Implant Lengths in the Posterior Maxilla by Three-Dimensional Finite Element Analysis.

Authors:  Cleidiel Aparecido Araujo Lemos; Fellippo Ramos Verri; Joel Ferreira Santiago Junior; Victor Eduardo de Souza Batista; Daniel Takanori Kemmoku; Pedro Yoshito Noritomi; Eduardo Piza Pellizzer
Journal:  J Healthc Eng       Date:  2018-09-03       Impact factor: 2.682

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.