Literature DB >> 768455

Design and technique variables affecting fracture resistance of metal-ceramic restorations.

W S Warpeha, R J Goodkind.   

Abstract

An attempt was made in this study to make a clinically meaningful measure of fracture resistance in metal-ceramic restorations. Forty-four solid metal-ceramic crown forms were fabricated and subjected to compressive load testings. Variables included the presence or absence of a metal coating agent, the type of metal preparation (using stones of different abrasives), and three designs of the underlying metal. The following conclusions were arrived at: (1) The design of the underlying metal structure had a significant relation to the ultimate fracture strength. (2) A design with a definite acuteness of the underlying metal structure failed at significantly lower ultimate fracture strengths. (3) A metal conditioning agent did not decrease fracture resistance if applied properly. (4) Fracture strength was severely decreased when (a) improper thickness of the coating agent was used and (b) porcelain was fused to an unoxidized metal surface. (5) Bond strength, although a contributing factor, may not be as important as metal design and proper manipulation of materials during fabrication of the restoration.

Entities:  

Mesh:

Substances:

Year:  1976        PMID: 768455     DOI: 10.1016/0022-3913(76)90253-5

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  6 in total

1.  Alternate metal framework designs for the metal ceramic prosthesis to enhance the esthetics.

Authors:  Naina Vilas Vernekar; Prithviraj Kallahalla Jagadish; Srinivasan Diwakar; Ramesh Nadgir; Manjunatha Revankar Krishnarao
Journal:  J Adv Prosthodont       Date:  2011-09-25       Impact factor: 1.904

2.  A study on the fracture strength of collarless metal-ceramic fixed partial dentures.

Authors:  Jong-Wook Yoon; Sung-Hun Kim; Jai-Bong Lee; Jung-Suk Han; Jae-Ho Yang
Journal:  J Adv Prosthodont       Date:  2010-12-31       Impact factor: 1.904

3.  X-Ray diffraction and scanning electron microscopy-energy dispersive spectroscopic analysis of ceramõmetal interface at different firing temperatures.

Authors:  Monika Saini; Suresh Chandra; Yashpal Singh; Bikramjit Basu; Arvind Tripathi
Journal:  Contemp Clin Dent       Date:  2010-07

4.  The Effects of New Design of Access Hole on Porcelain Fracture Resistance of Implant-Supported Crowns.

Authors:  Reza Derafshi; Mitra Farzin; Masoumeh Taghva; Hossein Heidary; Berivan Atashkar
Journal:  J Dent (Shiraz)       Date:  2015-03

5.  Fracture resistance of porcelain veneered zirconia crowns with exposed lingual zirconia for anterior teeth after thermal cycling: An in vitro study.

Authors:  Fatemeh A Amir Rad; Faysal G Succaria; Steven M Morgano
Journal:  Saudi Dent J       Date:  2015-01-30

6.  A comparative study on the bond strength of porcelain to the millingable Pd-Ag alloy.

Authors:  Jun-Tae Hong; Soo-Yeon Shin
Journal:  J Adv Prosthodont       Date:  2014-10-21       Impact factor: 1.904

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.