Literature DB >> 4001369

ECG-synchronized cardiac MR imaging: method and evaluation.

P Lanzer, C Barta, E H Botvinick, H U Wiesendanger, G Modin, C B Higgins.   

Abstract

An electrocardiographic (ECG) sensing and gating device compatible with a 0.35-tesla (T) magnetic resonance (MR) imager has been developed and used to produce 802 MR images of the heart in 30 patients. The instrument consists of an isolated acquisition module, an electrically floating preamplifier, and a monitor gating module. Two spin-echo images were acquired for each of five, 0.7-cm thick, transaxial sections from the base to the apex of the heart during each ECG-synchronized imaging run. Image quality was assessed in a blind study by two investigators, on a scale from 0 to 3, as diagnostic [2-3] or nondiagnostic [0-1]. There was agreement in 91.4% of their assessments of diagnostic images (68.1% of the images studied). Resolution of heart anatomy on the MR images was adversely affected by prolonged spin-echo time delay, imaging in late diastole, image acquisition at the cardiac apex, irregular triggering, and artifacts. The synchronization of gradient pulses to the ECG at 0.35 T appears safe for patients, permits diagnostic resolution of images, allows image acquisition at distinct points during the cardiac cycle, and enables monitoring of patients during imaging.

Entities:  

Mesh:

Year:  1985        PMID: 4001369     DOI: 10.1148/radiology.155.3.4001369

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  17 in total

1.  Self-gated PROPELLER-encoded cine cardiac imaging.

Authors:  Chi-Chung Wang; Teng-Yi Huang
Journal:  Int J Cardiovasc Imaging       Date:  2011-11-01       Impact factor: 2.357

2.  Displacement and velocity of the coronary arteries: cardiac and respiratory motion.

Authors:  Guy Shechter; Jon R Resar; Elliot R McVeigh
Journal:  IEEE Trans Med Imaging       Date:  2006-03       Impact factor: 10.048

Review 3.  Motion-compensation techniques in neonatal and fetal MR imaging.

Authors:  C Malamateniou; S J Malik; S J Counsell; J M Allsop; A K McGuinness; T Hayat; K Broadhouse; R G Nunes; A M Ederies; J V Hajnal; M A Rutherford
Journal:  AJNR Am J Neuroradiol       Date:  2012-05-10       Impact factor: 3.825

4.  Comparison of left ventricular function assessment using phonocardiogram- and electrocardiogram-triggered 2D SSFP CINE MR imaging at 1.5 T and 3.0 T.

Authors:  Meike Becker; Tobias Frauenrath; Fabian Hezel; Gabriele A Krombach; Ute Kremer; Benedikt Koppers; Christoph Butenweg; Andreas Goemmel; Jane F Utting; Jeanette Schulz-Menger; Thoralf Niendorf
Journal:  Eur Radiol       Date:  2009-12-16       Impact factor: 5.315

Review 5.  Will MRI of gastrointestinal function parallel the clinical success of cine cardiac MRI?

Authors:  Caroline Hoad; Christopher Clarke; Luca Marciani; Martin John Graves; Maura Corsetti
Journal:  Br J Radiol       Date:  2018-10-24       Impact factor: 3.039

Review 6.  Toward cardiovascular MRI at 7 T: clinical needs, technical solutions and research promises.

Authors:  Thoralf Niendorf; Daniel K Sodickson; Gabriele A Krombach; Jeanette Schulz-Menger
Journal:  Eur Radiol       Date:  2010-07-31       Impact factor: 5.315

Review 7.  Motion artifacts in MRI: A complex problem with many partial solutions.

Authors:  Maxim Zaitsev; Julian Maclaren; Michael Herbst
Journal:  J Magn Reson Imaging       Date:  2015-01-28       Impact factor: 4.813

8.  Registration of angiographic image on real-time fluoroscopic image for image-guided percutaneous coronary intervention.

Authors:  Dongkue Kim; Sangsoo Park; Myung Ho Jeong; Jeha Ryu
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-11-23       Impact factor: 2.924

9.  Magnetic resonance imaging of the heart compared with anatomic and ultrasonographic data.

Authors:  J L De Brux; J M Pernes; P h Grenier
Journal:  Surg Radiol Anat       Date:  1987       Impact factor: 1.246

10.  Acoustic cardiac triggering: a practical solution for synchronization and gating of cardiovascular magnetic resonance at 7 Tesla.

Authors:  Tobias Frauenrath; Fabian Hezel; Wolfgang Renz; Thibaut de Geyer d'Orth; Matthias Dieringer; Florian von Knobelsdorff-Brenkenhoff; Marcel Prothmann; Jeanette Schulz Menger; Thoralf Niendorf
Journal:  J Cardiovasc Magn Reson       Date:  2010-11-16       Impact factor: 5.364

View more