Literature DB >> 17457877

T2 measurement of the human myocardium using a T2-prepared transient-state TrueFISP sequence.

Teng-Yi Huang1, Yi-Jui Liu, Alto Stemmer, Brigitte P Poncelet.   

Abstract

A fast and motion-insensitive technique suitable for myocardial BOLD contrast imaging is presented. The method, termed T2-TrueFISP, combines T2 magnetization preparation with steady-state free precession (SSFP) imaging for T2 relaxation mapping of the myocardium in healthy volunteers. The T2 contrast-to-noise ratio (CNR) was optimized with the use of transient-state TrueFISP readout and half-Fourier readout with linear phase encoding. Single-slice myocardial T2-weighted image was obtained within one heartbeat, and a single slice T2 map of the myocardium was obtained in under 5-7 s. A respiratory navigator-gating method was incorporated for serial measurements and signal averaging, with the subjects breathing freely. The mean myocardial T2 relaxation time measured in 12 healthy volunteers was 54 +/- 5.7 ms. Regional variations of T2 values across the myocardium were 7%. Temporal variations across serial T2 measurements in a transmural region covering approximately 0.5 cc of the left ventricular (LV) wall were 3.6% without signal averaging (number of excitations (NEX) = 1) and 1.7% with signal averaging (NEX = 10). According to our preliminary results, the T2-TrueFISP method is expected to provide a robust and sensitive tool for clinical application of myocardial BOLD contrast imaging. (c) 2007 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2007        PMID: 17457877     DOI: 10.1002/mrm.21208

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  49 in total

1.  T(2) preparation method for measuring hyperemic myocardial O(2) consumption: in vivo validation by positron emission tomography.

Authors:  Kyle S McCommis; Robert O'Connor; Dana R Abendschein; David Muccigrosso; Robert J Gropler; Jie Zheng
Journal:  J Magn Reson Imaging       Date:  2011-02       Impact factor: 4.813

2.  Self-gated PROPELLER-encoded cine cardiac imaging.

Authors:  Chi-Chung Wang; Teng-Yi Huang
Journal:  Int J Cardiovasc Imaging       Date:  2011-11-01       Impact factor: 2.357

3.  Simultaneous multislice cardiac magnetic resonance fingerprinting using low rank reconstruction.

Authors:  Jesse I Hamilton; Yun Jiang; Dan Ma; Yong Chen; Wei-Ching Lo; Mark Griswold; Nicole Seiberlich
Journal:  NMR Biomed       Date:  2018-12-18       Impact factor: 4.044

4.  Free-breathing slice-interleaved myocardial T2 mapping with slice-selective T2 magnetization preparation.

Authors:  Tamer A Basha; Steven Bellm; Sébastien Roujol; Shingo Kato; Reza Nezafat
Journal:  Magn Reson Med       Date:  2015-10-19       Impact factor: 4.668

Review 5.  Quantitative relaxometry of the brain.

Authors:  Sean C L Deoni
Journal:  Top Magn Reson Imaging       Date:  2010-04

6.  T2 Relaxation Times at Cardiac MRI in Healthy Adults: A Systematic Review and Meta-Analysis.

Authors:  Christopher A Hanson; Akshay Kamath; Matthew Gottbrecht; Sami Ibrahim; Michael Salerno
Journal:  Radiology       Date:  2020-08-25       Impact factor: 11.105

7.  Molecular and Microstructural Imaging of the Myocardium.

Authors:  Shuning Huang; David E Sosnovik
Journal:  Curr Cardiovasc Imaging Rep       Date:  2010-02

8.  Simultaneous measurement of T2 and apparent diffusion coefficient (T2 +ADC) in the heart with motion-compensated spin echo diffusion-weighted imaging.

Authors:  Eric Aliotta; Kévin Moulin; Zhaohuan Zhang; Daniel B Ennis
Journal:  Magn Reson Med       Date:  2017-05-17       Impact factor: 4.668

9.  Quantification of global myocardial oxygenation in humans: initial experience.

Authors:  Kyle S McCommis; Robert O'Connor; Donna Lesniak; Matt Lyons; Pamela K Woodard; Robert J Gropler; Jie Zheng
Journal:  J Cardiovasc Magn Reson       Date:  2010-06-02       Impact factor: 5.364

10.  Improved in vivo measurement of myocardial transverse relaxation with 3 Tesla magnetic resonance imaging.

Authors:  Jared Guthrie Cobb; Cynthia B Paschal
Journal:  J Magn Reson Imaging       Date:  2009-09       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.