Literature DB >> 12781279

Early rotational stability of the longer Staar toric intraocular lens: fifty consecutive cases.

David F Chang.   

Abstract

PURPOSE: To determine whether rotational stability is improved with the longer Staar toric intraocular lens (IOL).
SETTING: A private practice, Los Altos, California, USA.
METHODS: Staar Surgical manufactures toric plate-haptic IOLs under +24.0 diopters (D) in 2 lengths. Fifty consecutive eyes requiring toric IOL spherical powers less than +24.0 D received the longer toric IOL (TL; 11.2 mm) using a specific surgical protocol. The IOL axis was recorded at 1 day, 1 week, and a final follow-up visit. Five additional eyes requiring powers greater than +24.0 D received the shorter toric IOL (TF; 10.8 mm), which is the only available length in these powers. Results were compared with those in an initial consecutive series of 6 eyes having implantation of the TF IOL with a power less than +24.0 D before the TL model became available.
RESULTS: Rotational stability of all 50 TL IOLs and the 5 TF IOLs of higher dioptric powers was excellent. One IOL rotated as much as 20 degrees off axis. The repositioning rate was zero in both groups. In the initial 6 eyes receiving the shorter toric IOL in powers below +24.0 D, the repositioning rate was 50%.
CONCLUSIONS: The longer toric IOL had excellent early rotational stability. Rotational and repositioning rates with the TL IOL were superior to those in a previous series of the TF IOL. Adequate overall length is a critical factor in the rotational stability of plate-haptic toric IOLs, and the longer IOL should be used when available.

Mesh:

Year:  2003        PMID: 12781279     DOI: 10.1016/s0886-3350(02)01843-6

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  23 in total

1.  An easy and practical method for toric intraocular lens implantation: marking corneal astigmatic axis at slit-lamp.

Authors:  Huseyin Bayramlar; Yaşar Dag; Remzi Karadag; Ozgur Cakici
Journal:  Int Ophthalmol       Date:  2016-05-12       Impact factor: 2.031

2.  Prevalence of corneal astigmatism before cataract surgery.

Authors:  Mehran Mohammadi; Mohammad Naderan; Rozhin Pahlevani; Ali Jahanrad
Journal:  Int Ophthalmol       Date:  2016-02-24       Impact factor: 2.031

3.  Simple and accurate alignment of toric intraocular lenses and evaluation of their rotation errors using anterior segment optical coherence tomography.

Authors:  Kazuhiro Watanabe; Kazuno Negishi; Hidemasa Torii; Megumi Saiki; Murat Dogru; Kazuo Tsubota
Journal:  Jpn J Ophthalmol       Date:  2011-10-29       Impact factor: 2.447

4.  Clinical outcomes of Ankoris toric intraocular lens implantation using a computer-assisted marker system.

Authors:  Biana Dubinsky-Pertzov; Idan Hecht; Inbal Gazit; Lior Or; Ori Mahler; Shlomo Rotman; Eran Pras; Adi Einan-Lifshitz
Journal:  Int Ophthalmol       Date:  2020-07-27       Impact factor: 2.031

5.  [Rotational stability in intraocular lenses with C-loop haptics versus Z haptics in cataract surgery. A prospective randomised comparison].

Authors:  I Warlo; F Krummenauer; H B Dick
Journal:  Ophthalmologe       Date:  2005-10       Impact factor: 1.059

6.  Clinical outcomes, predictability and rotational stability following implantation of Eyecryl toric versus TECNIS toric intraocular lenses-A comparative study.

Authors:  Sheetal Brar; Dishitha P Rathod; R P Nikhil; Sri Ganesh
Journal:  Int Ophthalmol       Date:  2021-07-22       Impact factor: 2.031

Review 7.  [The basics of refractive lens exchange].

Authors:  T Kohnen; O K Klaproth
Journal:  Ophthalmologe       Date:  2008-11       Impact factor: 1.059

8.  [Toric intraocular lenses for correction of persistent corneal astigmatism after penetrating keratoplasty].

Authors:  A Viestenz; M Küchle; B Seitz; A Langenbucher
Journal:  Ophthalmologe       Date:  2005-02       Impact factor: 1.059

9.  Acrylic toric intraocular lens implantation: a single center experience concerning clinical outcomes and postoperative rotation.

Authors:  Ioannis T Tsinopoulos; Konstantinos T Tsaousis; Dimitrios Tsakpinis; Nikolaos G Ziakas; Stavros A Dimitrakos
Journal:  Clin Ophthalmol       Date:  2010-03-24

Review 10.  [Toric IOLs after cataract surgery and refractive lens exchange].

Authors:  G U Auffarth; T M Rabsilber
Journal:  Ophthalmologe       Date:  2007-12       Impact factor: 1.059

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.