Literature DB >> 22036279

Effect of distal radius volar plate position on contact pressure between the flexor pollicis longus tendon and the distal plate edge.

Yoshitaka Tanaka1, Mitsuhiro Aoki, Tomoki Izumi, Mineko Fujimiya, Toshihiko Yamashita, Tomohito Imai.   

Abstract

PURPOSE: Some clinical studies have suggested that distal radius plates placed distal to the watershed line have the potential to impinge on the traversing flexor tendons. However, the validity of this theory remains unclear. The purpose of this study was to evaluate the quantitative effect of volar plate position on flexor pollicis longus (FPL) tendon friction by measuring the contact pressure between the FPL tendon and the distal edge of the locking plate.
METHODS: We used 7 fresh cadaveric upper extremities without wrist osteoarthritis or any deformity. External loads of 1.5 and 3.0 kgf were applied to the FPL tendon to simulate the pinch function of the thumb. A distal radius volar plate was applied to these cadaveric specimens in various positions relative to the watershed line. We measured contact pressure between the distal plate edge and the FPL tendon using a thin flexible pressure sensor and compared it among various positions of the volar plate for wrist extension angles of 0°, 30°, and 60° and ulnar deviation angles of 0° and 20°.
RESULTS: Under the 30° or 60° wrist extension condition, contact pressure significantly increased when the distal plate edge was placed distal to the watershed line, compared with when it was placed proximal to or at the watershed line.
CONCLUSIONS: Our quantitative results support the theory that plates placed distal to the watershed line have the potential to impinge on the traversing FPL tendon, even when a radius fracture heals anatomically. CLINICAL RELEVANCE: This study clarifies a mechanism of FPL tendon irritation after volar plate fixation for distal radius fractures. Copyright Â
© 2011 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 22036279     DOI: 10.1016/j.jhsa.2011.08.027

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  15 in total

1.  Impact of Design on Force between Flexor Tendons and Distal Radius Volar Plates.

Authors:  Katharine M Hinchcliff; Ido Volk; Xenia Ivanova; Sandra Taylor; Robert M Szabo
Journal:  J Wrist Surg       Date:  2019-03-25

2.  Investigating the minimum distance between the finger flexor tendons and distal radius during wrist and finger positions in healthy people.

Authors:  Kanta Imao; Hitoshi Miwa; Kazutoshi Watanabe; Tsuyoshi Satoh; Atsuki Sano; Naoto Endo
Journal:  J Med Ultrason (2001)       Date:  2019-03-06       Impact factor: 1.314

3.  Contact Pressure between Digital Flexors and Plates for Distal Radius Approaches.

Authors:  Christopher M Jones; Roshan Melvani; Keith T Aziz; Pooyan Abbasi; Kenneth R Means
Journal:  J Wrist Surg       Date:  2019-12-20

4.  The Watershed Line of the Distal Radius: Cadaveric and Imaging Study of Anatomical Landmarks.

Authors:  Minke Bergsma; Job N Doornberg; Annelise Borghorst; W A Kernkamp; R L Jaarsma; Gregory I Bain
Journal:  J Wrist Surg       Date:  2019-12-20

5.  Interpretations of the Term "Watershed Line" Used as Reference for Volar Plating.

Authors:  Minke Bergsma; Job N Doornberg; Laurent Hendrickx; Batur Hayat; Gino M M J Kerkhoffs; Bhavin Jhadav; Ruurd L Jaarsma; Gregory I Bain
Journal:  J Wrist Surg       Date:  2019-08-13

Review 6.  Distal radius fractures in the athlete.

Authors:  Casey Beleckas; Ryan Calfee
Journal:  Curr Rev Musculoskelet Med       Date:  2017-03

7.  Bony Anatomy around the Watershed Line of the Distal Radius.

Authors:  Kenny Tay; Hamid Rahmatullah Bin Abd Razak; Andy Khye Soon Yew; Joyce Suang Bee Koh; Tet S Howe
Journal:  J Wrist Surg       Date:  2020-11-04

Review 8.  Hand Surgeon Reporting of Tendon Rupture Following Distal Radius Volar Plating.

Authors:  Nathan A Monaco; C Liam Dwyer; Alex J Ferikes; John D Lubahn
Journal:  Hand (N Y)       Date:  2016-02-19

9.  Transverse ultrasound assessment of the flexor pollicis longus tendon movement on the distal radius during wrist and finger motion in distal radius fracture with volar plating.

Authors:  Mitsuhiko Nanno; Norie Kodera; Yuji Tomori; Shinro Takai
Journal:  J Med Ultrason (2001)       Date:  2015-09-13       Impact factor: 1.314

10.  Anatomical-positional relationship between the bone structure of the distal radius and flexor pollicis longus tendon using ultrasonography.

Authors:  Mayuko Kinoshita; Kiyohito Naito; Kenji Goto; Yoichi Sugiyama; Nana Nagura; Hiroyuki Obata; Yoshiyuki Iwase; Kazuo Kaneko
Journal:  Surg Radiol Anat       Date:  2019-03-16       Impact factor: 1.246

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.