Investigating the minimum distance between the finger flexor tendons and distal radius during wrist and finger positions in healthy people.

Kanta Imao1,2, Hitoshi Miwa3, Kazutoshi Watanabe3, Tsuyoshi Satoh3, Atsuki Sano3, Naoto Endo4.   

Abstract

PURPOSE: Rupture of the flexor pollicis longus (FPL) and index flexor digitorum profundus (FDP2) tendons often occurs after locking plate fixation for distal radius fracture. This study aimed to determine the shortest tendon-radius distances of different hand positions.
METHODS: Fifty-nine hands of 30 healthy volunteers were studied. Distances between the FPL or FDP2 and distal radius were calculated in six wrist positions: 30° palmar flexion, neutral, 30° dorsiflexion, 60° dorsiflexion, maximum dorsiflexion, and 40° ulnar deviation with three finger positions (full extension and flexion of fingers, full flexion of the thumb or index finger, and full extension of the other four fingers). The shortest distance between the FPL or FDP2 and distal radius was noted.
RESULTS: The shortest distance between the FPL and distal radius was during maximum wrist dorsiflexion with isolated thumb flexion. The distance between the FDP2 and distal radius was shortest with all-finger flexion in 30° wrist dorsiflexion.
CONCLUSIONS: It is necessary to measure the distance between the FPL and distal radius in maximal wrist dorsiflexion with full flexion of the isolated thumb, as the shortest distance was observed with flexion of the isolated thumb. On the contrary, we recommend measuring the distance between the FDP2 and distal radius in 30° wrist dorsiflexion with flexion of all fingers.

Entities:  

Keywords:  Distal radius; Flexor pollicis longus; Index flexor digitorum profundus; Ultrasound

Mesh:

Year:  2019        PMID: 30840213     DOI: 10.1007/s10396-019-00935-5

Source DB:  PubMed          Journal:  J Med Ultrason (2001)        ISSN: 1346-4523            Impact factor:   1.314


  21 in total

1.  Osteosynthesis of distal radial fractures with a volar locking screw plate system.

Authors:  H Drobetz; E Kutscha-Lissberg
Journal:  Int Orthop       Date:  2002-08-21       Impact factor: 3.075

2.  Flexor tendon injuries following locked volar plating of distal radius fractures.

Authors:  Andrew W Cross; Christopher C Schmidt
Journal:  J Hand Surg Am       Date:  2008-02       Impact factor: 2.230

Review 3.  Delayed rupture of the flexor pollicis longus tendon after routine volar placement of a T-plate on the distal radius.

Authors:  Scott F M Duncan; Andrew J Weiland
Journal:  Am J Orthop (Belle Mead NJ)       Date:  2007-12

4.  Flexor pollicis longus tendon ruptures after palmar plate fixation of fractures of the distal radius.

Authors:  J A Casaletto; D Machin; R Leung; D J Brown
Journal:  J Hand Surg Eur Vol       Date:  2009-04-24

5.  Flexor tendon problems after volar plate fixation of distal radius fractures.

Authors:  Mehdi N Adham; Margaret Porembski; Christine Adham
Journal:  Hand (N Y)       Date:  2009-03-13

6.  Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report.

Authors:  Jorge L Orbay; Diego L Fernandez
Journal:  J Hand Surg Am       Date:  2002-03       Impact factor: 2.230

7.  The treatment of unstable distal radius fractures with volar fixation.

Authors:  J L Orbay
Journal:  Hand Surg       Date:  2000-12

Review 8.  Current concepts in volar fixed-angle fixation of unstable distal radius fractures.

Authors:  Jorge L Orbay; Amel Touhami
Journal:  Clin Orthop Relat Res       Date:  2006-04       Impact factor: 4.176

9.  Rupture of flexor tendon following volar plate of distal radius fracture. Report of five cases.

Authors:  S E Valbuena; L K Cogswell; R Baraziol; P Valenti
Journal:  Chir Main       Date:  2010-02-06

10.  Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate.

Authors:  Rohit Arora; Martin Lutz; Alfred Hennerbichler; Dietmar Krappinger; David Espen; Markus Gabl
Journal:  J Orthop Trauma       Date:  2007-05       Impact factor: 2.512