Assessment of Bond Strength between Metal Brackets and Non-Glazed Ceramic in Different Surface Treatment Methods.

Ms Ahmad Akhoundi1, M Rahmati Kamel, T Hooshmand, I Harririan, Mj Kharazi Fard, H Noroozi.   

Abstract

OBJECTIVE: The aim of this study was to evaluate the bond strength between metal brackets and non-glazed ceramic with three different surface treatment methods.
MATERIALS AND METHODS: Forty-two non-glazed ceramic disks were assigned into three groups. Group I and II specimens were etched with 9.5% hydrofluoric acid. Subsequently in group I, silane and adhesive were applied and in group II, bonding agent was used only. In group III, specimens were treated with 35% phosphoric acid and then silane and adhesive were applied. Brackets were bonded with light-cured composites. The specimens were stored in water in room temperature for 24 hours and then thermocycled 500 times between 5°C and 55°C.
RESULTS: The difference of tensile bond strength between groups I and III was not significant (P=0.999). However, the tensile bond strength of group II was significantly lower than groups I, and III (P<0.001). The adhesive remnant index scores between the three groups had statistically significant differences (P<0.001).
CONCLUSION: With the application of scotch bond multi-purpose plus adhesive, we can use phosphoric acid instead of hydrofluoric acid for bonding brackets to non-glazed ceramic restorations.

Entities:  

Keywords:  Dental Porcelain; Orthodontic Brackets; Shear Strength

Year:  2010        PMID: 21998777      PMCID: PMC3184746     

Source DB:  PubMed          Journal:  J Dent (Tehran)        ISSN: 1735-2150


INTRODUCTION

As the demand for adult orthodontic treatment increases and the popularity of esthetic dentistry expands, orthodontists are more likely faced with the problem of placing orthodontic appliances on teeth restored with resin and porcelain fixed prostheses or veneer laminates. When esthetics is a concern, orthodontists will have to depend on the direct bonding technique. Numerous methods and materials have been suggested for bonding to ceramic restorations [1-7]. The conventional method for optimal bonding of brackets and retainer wires to ceramic surfaces is application of hydrofluoric (HF) acid for etching the ceramic surface, because phosphoric acid etching, which is used for the enamel, is ineffective in the preparation of ceramic surfaces for mechanical retention of orthodontic attachments [8-10]. However, the in vivo use of HF acid is too hazardous. Mucosal or skin contact with HF acid can cause erythema and burning associated with loss of tissue along with intense pain for several days [11,12]. The purpose of this study was to evaluate tensile bond strength between metal brackets and non-glazed ceramic surfaces with three different surface treatments to evaluate application of phosphoric acid instead of HF acid. We evaluated the non-glazed ceramic surfaces because clinicians sometimes remove the glaze layer of porcelain restorations by a low speed bur in the oral cavity and then apply phosphoric acid instead of HF. This study can show if this is an effective way to prepare porcelain.

MATERIALS AND METHODS

Forty-two non-glazed, feldspathic porcelain disks, 2.0 mm thick and 8.0 mm in diameter, were used. The disks were fabricated from super porcelain EX-3 body (Noritake, Japan) using a handmade mold. All specimens were made by one skilled ceramic technician and were checked for cracks. The specimens were washed with water, dried with air, and then divided into three equal groups randomly. In groups I, and II; 9.5% HF acid gel (Ultradent, USA) was applied for 2 minutes, then rinsed with water and dried with oil-free air. Subsequently, in group I, a layer of silane (Scotchbond Ceramic Primer, 3M Unitek, USA) was applied and dried with light oil-free air spray. Then a layer of scotchbond multi purpose plus adhesive (3M Unitek, Monrovia, Calif., USA) was applied, thinned with air spray and cured with light (500) for 10 seconds. In group II, after etching with 9.5% HF acid, only a layer of bonding agent (Unfilled resin, 3M Unitek, USA) was used. In group III, ceramic surfaces were treated with 35% phosphoric acid (3M Unitek, USA) and then silane and adhesive were applied similar to group I. Metal brackets for maxillary central incisors (Dyna lock, Std. Edgewise 018″, 3M-Unitek, USA) were bonded to each conditioned ceramic surface with light-curing composite resin (transbond XT, 3M-Unitek, USA). The bracket was subjected to 250 grams of force. Excess composite was removed and then light cured for 40 seconds (Coltolux 75, Swiss) with an intensity of 500. The surface areas for the bases of brackets was 16.52 mm2 which were obtained bfrom the manufacturer. After bonding, all specimens were stored in a water bath in room temperature for 24 hours, then thermocycled 500 times between 5°C and 55°C with a dwelling time of 60 seconds. The transfer time between baths was eight seconds. All specimens were partially embedded in acrylic resin using a hand-made jig, especially designed for this purpose (Fig 1 and 2).
Fig 1.

Specimens were mounted in acrylic resin in a special jig.

Fig 2.

Specimens after mounting in acrylic resin.

Zwick universal testing machine (Z/100, Germany) was used to measure the tensile bond strength. The machine had an upper jaw that was mounted to a movable crosshead and a lower jaw mounted on the base. The tensile force at a crosshead speed of 0.5 mm/minute was transmitted to the bracket by a steel wire that was placed under the bracket wings. The wire was pulled upward until bond failure occurred (Fig 3).
Fig 3.

Specimen setup for testing the tensile bond strength in a universal testing machine.

The force required for debonding was recorded and the tensile bond strength in megapascal (MPa) was determined from the load at failure and the area of bracket base. After debonding, the specimen surface was examined under magnification ×2 to determine how much residual adhesive remained on the ceramic according to the following scale: 1=all the composite remained on the ceramic, 2=more than 90% of the composite remained on the ceramic, 3=more than 10% but less than 90% remained on the ceramic, 4=less than 10% remained on the ceramic, and 5=no composite remained on the ceramic. Descriptive statistics including the mean, standard deviation, and minimum and maximum values were calculated for the three groups. Then tensile bond strength data were subjected to one-way ANOVA and Tukey’s HSD Post Hoc tests. The nonparametric Kruskal-Wallis test was used to compare the adhesive remnant index (ARI) score for the three groups. Significance for all statistical tests was predetermined at P≤0.05.

RESULTS

Four specimens in group I, three specimens in group II, and two specimens in group III did not have a measurement of tensile bond strength because of the operator’s mistake. Table I shows the descriptive statistics of the three groups. The difference of tensile bond strength between groups I, and III was not significant (P=0.999). However, the tensile bond strength of group II was significantly lower than groups I, and III (P<0.001).
Table 1.

Descriptive statistics of the groups.

GroupNMean (MPa)Standard DeviationMinMax
1103.910.203.704.31
2112.700.461.753.32
3123.900.892.035.43
The ARI scores show that in group I specimens, all the composite remained on the ceramic. In group II, 63.7% of the specimens had an ARI higher than 4, meaning that less than 10% of the composite remained on the ceramic. In group III, more than half of the specimens had an ARI lower than 2 (i.e. more than 90% of the composite remained on the ceramic). The ARI scores between the three groups had statistically significant differences (P<0.001).

DISCUSSION

The direct bonding of orthodontic attachments has revolutionized and improved the clinical practice of orthodontics. More recently bonding materials have been introduced for bonding to ceramic. However, before clinical experiments, these materials should be evaluated in vitro to find which products and materials seem most valuable to include in supplementary clinical evaluation [10]. Although both shear and tensile loading modes are valid tests for studying bond strengths of orthodontic materials [13], choosing the tensile bond strength test as the more frequently used shear bond strength test needs some explanation. In order to allow the calculation of the true interfacial failure stress, the experiment should be designed so that a uniform stress distribution is created across the interface. Production of complex stress distribution in the shear bond strength test may start fracture at sites with high concentration of local stress; therefore, the adhesive characteristics of the bonded interface are not expressed [14]. The tensile bond strength test used in this study provides a specimen design with a stress distribution across the interface as near to uniform as possible. We used long thin wires under the bracket wings, as suggested by Katone and Chan [15]. The relatively slow crosshead speed used for bond strength in this study does allow some self-adjustment of the experimental configuration during loading. Moreover, viscoelastic behavior that is absent in vivo may occur at low strain rates for the adhesive which may be an important area for future investigation [13,16]. Newman [17] stated that 14 kg/cm2 (∼1.5 MPa) was the maximum force that could be applied to a tooth by an orthodontic appliance. The tensile bond strength in our study exceeded this value greatly, but were still less than Reynold’s value [18] (50 kg/cm2∼5 MPa) recommended for in vivo success. Group I and III had the closest results to this value with a mean of 3.91 MPa and 3.90 MPa, respectively. Olsen et al [19] evaluated shear bond strength between metal brackets and enamel using scotch bond multipurpose adhesive, 37% phosphoric acid and 10% maleic acid. Their results were 13.1 MPa (SD=4.8) for phosphoric acid and 10.3 MPa (SD=3.1) for maleic acid. They did not thermocycle their specimens. Moreover, it is proved in orthodontics that shear bond strength is higher than tensile bond strength [20-22]. Thurmond et al [23] found significantly lower shear bond strength with application of phosphoric acid plus silane on ceramic than with HF acid plus silane (P<0.001), but Saygili and Sahmali [24] reported that acid etching of the surfaces with HF acid had a weak tendency to improve bond strength. Aida et al [25] showed that acid etching of porcelain with HF acid could be eliminated. Our finding showed no statistical difference between application of HF acid with scotch bond multipurpose plus adhesive and phosphoric acid with scotch bond multipurpose plus adhesive on non-glazed ceramic (P=0.999). Major et al [26] showed that the site of failure at low bond strength tended to be at the porcelain-adhesive interface. When the bond strengths became greater, the chemical retention was equal or exceeded the mechanical retention provided by the bracket base. Therefore, increased bond strengths resulted in failure at the bracket-adhesive interface or a cohesive failure within the composite resin in a way that some composite was left on both the bracket and the porcelain surfaces. In our study, in group I, 100% of the specimens and in group III, 60% of the specimens had more than 90% composite remaining on the ceramic. However, in group II, which had a lower bond strength (2.70 MPa), about 60% of the specimens had less than 10% composite remaining on the ceramic. The tensile bond strength to ceramic surface reported by Cochran et al [27], Kocadereli et al [28] and Harari et al [29] using the same method were higher than our results. But it should be noted that they did not thermocycle their specimens and they also used different material. Zachresson et al [9] stated their results should be interpreted cautiously. Eustaquio et al [30] reported a tensile bond strength of bonding brackets to deglazed ceramic using conocise/scotch prime (3M) comparable with groups I and III of our study. Overall, these differences may be due to variables such as the type of bond strength test, ceramic, adhesive, brackets, storage environment and presence or absence of thermocycling. In some researches, the specimens were stored in 37 degrees and in others; they were kept in room temperature. We used the second method [31,32]. Regarding the effect of phosphoric acid on porcelain, the results of studies are mixed and confusing. While some researches show that this acid does not have a considerable effect on the porcelain surface [8-10], others show that this effect is clinically acceptable [33-35]. Our results were in accordance with the second opinion. The number of thermal cycle is another point of dispute between different researches. It has been 100, 150, 200 and 500 times in previous researches. We applied the biggest number in our research [1,17,20,32,36].

CONCLUSION

Our results showed that by using scotch bond multipurpose plus adhesive on non-glazed ceramic we can use phosphoric acid for treating the ceramic surface instead of HF acid gaining a statistically not different tensile bond strength and also preventing hazard for the oral tissue, skin and the respiratory system.
Table 2.

Adhesive Remnant Index (ARI) scores for the groups.

GroupARI
Total
12345
1Count10000010
% Within Group100.0%0%0%0%0%100.0%
2Count1125211
% Within Group9.1%9.1%18.2%45.5%18.2%100.0%
3Count5241012
% Within Group41.716.733.3%8.3%0%100.0%
  33 in total

1.  Tensile bond strength of ceramic brackets bonded to porcelain facets.

Authors:  Doron Harari; Shirley Shapira-Davis; Immanuel Gillis; Itzchak Roman; Meir Redlich
Journal:  Am J Orthod Dentofacial Orthop       Date:  2003-05       Impact factor: 2.650

2.  Factors affecting the shear bond strength of orthodontic brackets to porcelain.

Authors:  B M Bourke; W P Rock
Journal:  Br J Orthod       Date:  1999-12

3.  An investigation into the bonding of orthodontic attachments to porcelain.

Authors:  C J Larmour; G Bateman; D R Stirrups
Journal:  Eur J Orthod       Date:  2005-09-30       Impact factor: 3.075

4.  Repair of fractured porcelain denture teeth.

Authors:  D G Jochen
Journal:  J Prosthet Dent       Date:  1973-02       Impact factor: 3.426

5.  Adhesion of composite to porcelain with various surface conditions.

Authors:  M Aida; T Hayakawa; K Mizukawa
Journal:  J Prosthet Dent       Date:  1995-05       Impact factor: 3.426

6.  Engineering and experimental analyses of the tensile loads applied during strength testing of direct bonded orthodontic brackets.

Authors:  T R Katona; J Chen
Journal:  Am J Orthod Dentofacial Orthop       Date:  1994-08       Impact factor: 2.650

7.  24-hour shear bond strength of metal orthodontic brackets bonded to porcelain using various adhesion promoters.

Authors:  P W Major; J R Koehler; K E Manning
Journal:  Am J Orthod Dentofacial Orthop       Date:  1995-09       Impact factor: 2.650

8.  Hydrofluoric acid burns.

Authors:  P A Moore; R C Manor
Journal:  J Prosthet Dent       Date:  1982-03       Impact factor: 3.426

9.  Direct bonding to porcelain.

Authors:  V L Barbosa; M A Almeida; O Chevitarese; O Keith
Journal:  Am J Orthod Dentofacial Orthop       Date:  1995-02       Impact factor: 2.650

10.  Effect of ceramic surface treatment on the shear bond strengths of two resin luting agents to all-ceramic materials.

Authors:  G Saygili; S Sahmali
Journal:  J Oral Rehabil       Date:  2003-07       Impact factor: 3.837

View more
  3 in total

1.  Tensile bond strength of metal bracket bonding to glazed ceramic surfaces with different surface conditionings.

Authors:  Ms Ahmad Akhoundi; M Rahmati Kamel; Sh Mahmood Hashemi; M Imani
Journal:  J Dent (Tehran)       Date:  2011-12-20

2.  Effect of Four Methods of Surface Treatment on Shear Bond Strength of Orthodontic Brackets to Zirconium.

Authors:  Soghra Yassaei; Hossein Agha Aghili; Abdolrahim Davari; Seyed Morteza Saadat Mostafavi
Journal:  J Dent (Tehran)       Date:  2015-04

Review 3.  Shear bond strength of brackets bonded to porcelain surface: in vitro study.

Authors:  Fidan Alakus Sabuncuoglu; Ergul Erturk
Journal:  J Istanb Univ Fac Dent       Date:  2016-01-12
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.