Accelerated Monte Carlo based dose calculations for brachytherapy planning using correlated sampling.

Håkan Hedtjärn1, Gudrun Alm Carlsson, Jeffrey F Williamson.   

Abstract

Current brachytherapy dose calculations ignore applicator attenuation and tissue heterogeneities, assuming isolated sources embedded in unbounded medium. Conventional Monte Carlo (MC) dose calculations, while accurate, are too slow for practical treatment planning. This study evaluates the efficacy of correlated sampling in reducing the variance of MC photon transport simulation in typical brachytherapy geometries. Photon histories were constructed in the homogeneous geometry and weight correction factors applied to account for the perturbing effect of heterogeneities. Two different estimators, expected value track-length (ETL) and analogue (ANL), were used. The method was tested for disc-shaped heterogeneities and point-isotropic sources as well as for a model 6702 125I seed. Uncorrelated ETL estimation was 10-100 times more efficient than its ANL counterpart. Correlated ETL estimation offered efficiency gains as large as 10(4) in regions where dose perturbations are small (<5%). For perturbations of 40-50%, efficiency gains were in some cases even less than unity. However, correlated ETL was capable of producing less than 2% (I standard deviation) uncertainty in more than 90% of the voxels in 1 CPU hour. Correlated sampling significantly improves efficiency under selected circumstances and, in combination with other variance reduction strategies, may make MC-based treatment planning a reality for brachytherapy.

Mesh:

Year:  2002        PMID: 11848117     DOI: 10.1088/0031-9155/47/3/301

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

Review 1.  A review of dosimetric impact of implementation of model-based dose calculation algorithms (MBDCAs) for HDR brachytherapy.

Authors:  Yousif A M Yousif; Alexander F I Osman; Mohammed A Halato
Journal:  Phys Eng Sci Med       Date:  2021-06-17

2.  Estimating statistical uncertainty of Monte Carlo efficiency-gain in the context of a correlated sampling Monte Carlo code for brachytherapy treatment planning with non-normal dose distribution.

Authors:  Nitai D Mukhopadhyay; Andrew J Sampson; Daniel Deniz; Gudrun Alm Carlsson; Jeffrey Williamson; Alexandr Malusek
Journal:  Appl Radiat Isot       Date:  2011-09-29       Impact factor: 1.513

3.  Fast patient-specific Monte Carlo brachytherapy dose calculations via the correlated sampling variance reduction technique.

Authors:  Andrew Sampson; Yi Le; Jeffrey F Williamson
Journal:  Med Phys       Date:  2012-02       Impact factor: 4.071

  3 in total