Literature DB >> 24557934

Radiographic evaluation of bone adaptation adjacent to percutaneous osseointegrated prostheses in a sheep model.

Sujee Jeyapalina1, James Peter Beck, Kent N Bachus, Ornusa Chalayon, Roy D Bloebaum.   

Abstract

BACKGROUND: Percutaneous osseointegrated prostheses (POPs) are being investigated as an alternative to conventional socket suspension and require a radiographic followup in translational studies to confirm that design objectives are being met. QUESTIONS/PURPOSES: In this 12-month animal study, we determined (1) radiographic signs of osseointegration and (2) radiographic signs of periprosthetic bone hypertrophy and resorption (adaptation) and (3) confirmed them with the histologic evidence of host bone osseointegration and adaptation around a novel, distally porous-coated titanium POP with a collar.
METHODS: A POP device was designed to fit the right metacarpal bone of sheep. Amputation and implantation surgeries (n = 14) were performed, and plane-film radiographs were collected quarterly for 12 months. Radiographs were assessed for osseointegration (fixation) and bone adaptation (resorption and hypertrophy). The cortical wall and medullary canal widths were used to compute the cortical index and expressed as a percentage. Based on the cortical index changes and histologic evaluations, bone adaptation was quantified.
RESULTS: Radiographic data showed signs of osseointegration including those with incomplete seating against the collar attachment. Cortical index data indicated distal cortical wall thinning if the collar was not seated distally. When implants were bound proximally, bone resorbed distally and the diaphyseal cortex hypertrophied.
CONCLUSIONS: Histopathologic evidence and cortical index measurements confirmed the radiographic indications of adaptation and osseointegration. Distal bone loading, through collar attachment and porous coating, limited the distal bone resorption. CLINICAL RELEVANCE: Serial radiographic studies, in either animal models or preclinical trials for new POP devices, will help to determine which designs are likely to be safe over time and avoid implant failures.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24557934      PMCID: PMC4160482          DOI: 10.1007/s11999-014-3523-z

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  20 in total

1.  Osseocutaneous integration of an intraosseous transcutaneous amputation prosthesis implant used for reconstruction of a transhumeral amputee: case report.

Authors:  Norbert V Kang; Catherine Pendegrass; Linda Marks; Gordon Blunn
Journal:  J Hand Surg Am       Date:  2010-06-11       Impact factor: 2.230

2.  Transcutaneous, distal femoral, intramedullary attachment for above-the-knee prostheses: an endo-exo device.

Authors:  Horst Heinrich Aschoff; Robert E Kennon; John M Keggi; Lee E Rubin
Journal:  J Bone Joint Surg Am       Date:  2010-12       Impact factor: 5.284

3.  Socket versus bone-anchored trans-femoral prostheses: hip range of motion and sitting comfort.

Authors:  K Hagberg; E Häggström; M Uden; R Brånemark
Journal:  Prosthet Orthot Int       Date:  2005-08       Impact factor: 1.895

4.  Cortical bone response to the presence of load-bearing percutaneous osseointegrated prostheses.

Authors:  Sujee Jeyapalina; James Peter Beck; Kent N Bachus; Roy D Bloebaum
Journal:  Anat Rec (Hoboken)       Date:  2012-07-16       Impact factor: 2.064

5.  Percutaneous osseointegrated prostheses for amputees: Limb compensation in a 12-month ovine model.

Authors:  Trevor J Shelton; J Peter Beck; Roy D Bloebaum; Kent N Bachus
Journal:  J Biomech       Date:  2011-09-13       Impact factor: 2.712

6.  Efficacy of a porous-structured titanium subdermal barrier for preventing infection in percutaneous osseointegrated prostheses.

Authors:  Sujee Jeyapalina; James Peter Beck; Kent N Bachus; Dustin L Williams; Roy D Bloebaum
Journal:  J Orthop Res       Date:  2012-01-31       Impact factor: 3.494

7.  Questionnaire for Persons with a Transfemoral Amputation (Q-TFA): initial validity and reliability of a new outcome measure.

Authors:  Kerstin Hagberg; Rickard Brånemark; Olle Hägg
Journal:  J Rehabil Res Dev       Date:  2004-09

8.  Walking ability and quality of life in subjects with transfemoral amputation: a comparison of osseointegration with socket prostheses.

Authors:  Hendrik Van de Meent; Maria T Hopman; Jan Paul Frölke
Journal:  Arch Phys Med Rehabil       Date:  2013-06-14       Impact factor: 3.966

9.  One hundred patients treated with osseointegrated transfemoral amputation prostheses--rehabilitation perspective.

Authors:  Kerstin Hagberg; Rickard Brånemark
Journal:  J Rehabil Res Dev       Date:  2009

10.  Stable fixation of an osseointegated implant system for above-the-knee amputees: titel RSA and radiographic evaluation of migration and bone remodeling in 55 cases.

Authors:  Audrey Nebergall; Charles Bragdon; Anne Antonellis; Johan Kärrholm; Rickard Brånemark; Henrik Malchau
Journal:  Acta Orthop       Date:  2012-04-11       Impact factor: 3.717

View more
  5 in total

Review 1.  Biomechanical Characterisation of Bone-anchored Implant Systems for Amputation Limb Prostheses: A Systematic Review.

Authors:  Alexander Thesleff; Rickard Brånemark; Bo Håkansson; Max Ortiz-Catalan
Journal:  Ann Biomed Eng       Date:  2018-01-11       Impact factor: 3.934

2.  Upper extremity prosthetic selection influences loading of transhumeral osseointegrated systems.

Authors:  Carolyn E Taylor; Alex J Drew; Yue Zhang; Yuqing Qiu; Kent N Bachus; K Bo Foreman; Heath B Henninger
Journal:  PLoS One       Date:  2020-08-06       Impact factor: 3.752

3.  Finite Element Analysis of Transhumeral and Transtibial Percutaneous Osseointegrated Endoprosthesis Implantation.

Authors:  Carolyn E Taylor; Heath B Henninger; Kent N Bachus
Journal:  Front Rehabil Sci       Date:  2021-11-23

4.  Osseointegrated Transcutaneous Device for Amputees: A Pilot Large Animal Model.

Authors:  Brian T Grisez; Andrew E Hanselman; Karim W Boukhemis; Trapper A J Lalli; Brock A Lindsey
Journal:  Adv Orthop       Date:  2018-09-13

5.  Variation in bone response to the placement of percutaneous osseointegrated endoprostheses: A 24-month follow-up in sheep.

Authors:  Sujee Jeyapalina; James Peter Beck; Alex Drew; Roy D Bloebaum; Kent N Bachus
Journal:  PLoS One       Date:  2019-10-25       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.