Proximal migration and compaction of an Enterprise stent into a coiled basilar apex aneurysm: a posterior circulation phenomenon?

Shervin R Dashti1, David Fiorella, Maria M Toledo, Yin Hu, Cameron G McDougall, Felipe C Albuquerque.   

Abstract

A patient with a giant partially thrombosed basilar apex aneurysm was treated with balloon-assisted coil embolization. At the conclusion of the embolization, an Enterprise stent was placed from the upper basilar artery to the left P1 segment. Follow-up angiography 4 months later showed that the distal stent had pulled out of the posterior cerebral artery and was in the coil mass within the aneurysm. Angiography clearly showed that the stent had migrated down the basilar artery and that the artery was now kinked proximal to the stent. Nonetheless, the left posterior cerebral artery and the basilar artery were still widely patent. This is the first documented case in which a stent 'compacted' into a completed coiled aneurysm in a delayed fashion.

Entities:  

Mesh:

Year:  2010        PMID: 21990647     DOI: 10.1136/jnis.2010.002444

Source DB:  PubMed          Journal:  J Neurointerv Surg        ISSN: 1759-8478            Impact factor:   5.836


  10 in total

1.  Treatment of a pediatric recurrent fusiform middle cerebral artery (MCA) aneurysm with a flow diverter.

Authors:  Anthony M Burrows; Gregory Zipfel; Giuseppe Lanzino
Journal:  BMJ Case Rep       Date:  2012-11-15

Review 2.  Natural history and management of posterior cerebral artery aneurysms: a systematic review and meta-analysis of individual patient data.

Authors:  Muhammed Amir Essibayi; Soliman H Oushy; Zafer Keser; Giuseppe Lanzino
Journal:  Neurosurg Rev       Date:  2022-10-12       Impact factor: 2.800

3.  Stent-Assisted Clip Placement for Complex Internal Carotid Artery Intracranial Aneurysms.

Authors:  Adnan I Qureshi; Morad Chughtai; Asif A Khan; M Fareed K Suri; Gregory T Sherr
Journal:  J Vasc Interv Neurol       Date:  2016-01

4.  First Experiences with the New Enterprise2® Stent.

Authors:  C Herweh; S Nagel; J Pfaff; C Ulfert; M Wolf; M Bendszus; M Möhlenbruch
Journal:  Clin Neuroradiol       Date:  2016-09-27       Impact factor: 3.649

5.  Spontaneous delayed migration/shortening of the pipeline embolization device: report of 5 cases.

Authors:  N Chalouhi; S I Tjoumakaris; L F Gonzalez; D Hasan; P J Pema; G Gould; R H Rosenwasser; P M Jabbour
Journal:  AJNR Am J Neuroradiol       Date:  2013-06-27       Impact factor: 3.825

6.  Novel balloon application for rescue and realignment of a proximal end migrated pipeline flex embolization device into the aneurysmal sac: complication management.

Authors:  Mario Martínez-Galdámez; Joaquin Ortega-Quintanilla; Antonio Hermosín; Eduardo Crespo-Vallejo; Juan José Ailagas; Santiago Pérez
Journal:  BMJ Case Rep       Date:  2016-03-23

7.  Pipeline Embolization Device for Salvage Treatment of a Willis Covered Stent Prolapse Into the Aneurysmal Sac.

Authors:  Zeng-Bao Wu; Sheng Wang; Li-Gang Song; Xin-Jian Yang; Shi-Qing Mu
Journal:  Front Neurol       Date:  2019-10-17       Impact factor: 4.003

8.  The Enterprise2 Stent for Endovascular Treatment of Intracranial Aneurysms: Short-Term Results From a Single Center Experience.

Authors:  Linhui Chen; Chaobo Zheng; Jiong Wu; Jie Gong; Yuhai Gao; Shu Wan
Journal:  Front Neurol       Date:  2020-12-03       Impact factor: 4.003

9.  Anchoring Pipeline Flow Diverter Construct in the Treatment of Traumatic Distal Cervical Carotid Artery Injury.

Authors:  Krishna Amuluru; Fawaz Al-Mufti; William Roth; Charles J Prestigiacomo; Chirag D Gandhi
Journal:  Interv Neurol       Date:  2017-04-19

10.  Stent-assisted coiling of broad-necked intracranial aneurysms with a new braided microstent (Accero): procedural results and long-term follow-up.

Authors:  Oliver Beuing; Anja Lenz; Aneta Donitza; Mathias Becker; Steffen Serowy; Martin Skalej
Journal:  Sci Rep       Date:  2020-01-15       Impact factor: 4.379

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.