Literature DB >> 21990329

Error analysis of nonconstant admittivity for MR-based electric property imaging.

Jin Keun Seo1, Min-Oh Kim, Joonsung Lee, Narae Choi, Eung Je Woo, Hyung Joong Kim, Oh In Kwon, Dong-Hyun Kim.   

Abstract

Magnetic resonance electrical property tomography (MREPT) is a new imaging modality to visualize a distribution of admittivity γ = σ+iωε inside the human body where σ and ε denote electrical conductivity and permittivity, respectively. Using B1 maps acquired by an magnetic resonance imaging scanner, it produces cross-sectional images of σ and ε at the Larmor frequency. Since current MREPT methods rely on an assumption of a locally homogeneous admittivity, there occurs a reconstruction error where this assumption fails. Rigorously analyzing the reconstruction error in MREPT, we showed that the error is fundamental and may cause technical difficulties in interpreting MREPT images of a general inhomogeneous object. We performed numerical simulations and phantom experiments to quantitatively support the error analysis. We compared the MREPT image reconstruction problem with that of magnetic resonance electrical impedance tomography (MREIT) to highlight distinct features of both methods to probe the same object in terms of its high- and low-frequency conductivity distributions, respectively. MREPT images showed large errors along boundaries where admittivity values changed whereas MREIT images showed no such boundary effects. Noting that MREIT makes use of the term neglected in MREPT, a novel MREPT admittivity image reconstruction method is proposed to deal with the boundary effects, which requires further investigation on the complex directional derivative in the real Euclidian space [Formula: see text].

Entities:  

Mesh:

Year:  2011        PMID: 21990329     DOI: 10.1109/TMI.2011.2171000

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  20 in total

1.  Tissue electrical property mapping from zero echo-time magnetic resonance imaging.

Authors:  Seung-Kyun Lee; Selaka Bulumulla; Florian Wiesinger; Laura Sacolick; Wei Sun; Ileana Hancu
Journal:  IEEE Trans Med Imaging       Date:  2014-10-08       Impact factor: 10.048

2.  Correlation between electrical conductivity and apparent diffusion coefficient in breast cancer: effect of necrosis on magnetic resonance imaging.

Authors:  Soo-Yeon Kim; Jaewook Shin; Dong-Hyun Kim; Eun-Kyung Kim; Hee Jung Moon; Jung Hyun Yoon; Jai Kyung You; Min Jung Kim
Journal:  Eur Radiol       Date:  2018-03-06       Impact factor: 5.315

3.  Simultaneous Quantitative Imaging of Electrical Properties and Proton Density From B1 Maps Using MRI.

Authors:  Pierre-Francois Van de Moortele
Journal:  IEEE Trans Med Imaging       Date:  2016-09       Impact factor: 10.048

4.  Brain Tissue Conductivity Measurements with MR-Electrical Properties Tomography: An In Vivo Study.

Authors:  Stefano Mandija; Petar I Petrov; Jord J T Vink; Sebastian F W Neggers; Cornelis A T van den Berg
Journal:  Brain Topogr       Date:  2020-12-08       Impact factor: 3.020

5.  Magnetic resonance electrical property mapping at 21.1 T: a study of conductivity and permittivity in phantoms, ex vivo tissue and in vivo ischemia.

Authors:  Ghoncheh Amouzandeh; Frederic Mentink-Vigier; Shannon Helsper; F Andrew Bagdasarian; Jens T Rosenberg; Samuel C Grant
Journal:  Phys Med Biol       Date:  2020-02-28       Impact factor: 3.609

6.  In vivo imaging of electrical properties of an animal tumor model with an 8-channel transceiver array at 7 T using electrical properties tomography.

Authors:  Jiaen Liu; Qi Shao; Yicun Wang; Gregor Adriany; John Bischof; Pierre-Francois Van de Moortele; Bin He
Journal:  Magn Reson Med       Date:  2017-01-23       Impact factor: 4.668

Review 7.  Magnetic-resonance-based electrical properties tomography: a review.

Authors:  Xiaotong Zhang; Jiaen Liu; Bin He
Journal:  IEEE Rev Biomed Eng       Date:  2014

8.  Correlation between conductivity and prognostic factors in invasive breast cancer using magnetic resonance electric properties tomography (MREPT).

Authors:  Soo-Yeon Kim; Jaewook Shin; Dong-Hyun Kim; Min Jung Kim; Eun-Kyung Kim; Hee Jung Moon; Jung Hyun Yoon
Journal:  Eur Radiol       Date:  2015-10-23       Impact factor: 5.315

9.  Simultaneous imaging of in vivo conductivity and susceptibility.

Authors:  Dong-Hyun Kim; Narae Choi; Sung-Min Gho; Jaewook Shin; Chunlei Liu
Journal:  Magn Reson Med       Date:  2014-03       Impact factor: 4.668

10.  Gradient-based electrical properties tomography (gEPT): A robust method for mapping electrical properties of biological tissues in vivo using magnetic resonance imaging.

Authors:  Jiaen Liu; Xiaotong Zhang; Sebastian Schmitter; Pierre-Francois Van de Moortele; Bin He
Journal:  Magn Reson Med       Date:  2014-09-11       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.