Changes in roughness of denture base and reline materials by chemical disinfection or microwave irradiation: surface roughness of denture base and reline materials.

Ana Lucia Machado1, Eunice Teresinha Giampaolo, Carlos Eduardo Vergani, Juliana Feltrin de Souza, Janaina Habib Jorge.   

Abstract

OBJECTIVE: The effect of disinfection by immersion in sodium perborate solution and microwave irradiation on surface roughness of one denture base resin (Lucitone 550 -L), 3 hard chairside reline resins (Tokuyama Rebase II-TR, New Truliner-NT, Ufi Gel hard-UH) and 3 resilient reline materials (Trusoft-T; Sofreliner-S, Dentusil-D) was evaluated.
MATERIAL AND METHODS: Thirty specimens of each material were made and divided into 3 groups: Control - not disinfected; P - daily disinfection by immersing in sodium perborate solution (3.8%); MW - microwave disinfection (6 min/650 W). Roughness measurements were made after polymerization (baseline) and after 1, 3 and 28 days. Roughness differences relative to the baseline readings were analyzed by Student's t-test (P=0.05).
RESULTS: At baseline, Trusoft showed the highest (P<0.001) mean surface roughness (3.54 µm), and its surface roughness was significantly reduced after 28 days of disinfection by immersion in sodium perborate (P=0.013). Roughness measurements of material Trusoft were not performed after microwave disinfection due to the severe alterations on the surface. In the 3 groups evaluated, changes in roughness were significant for materials Ufi Gel hard (from 0.11 to 0.26 µm; P<0.041) and New Truliner (0.19 to 0.76 µm; P<0.019). The roughness of materials Lucitone 550 (0.37 µm), Tokuyama Rebase II (0.37 µm), Sofreliner (0.49 µm) and Dentusil (0.38 µm) remained unaffected (P>0.05).
CONCLUSIONS: The roughness of the hard reline materials Ufi Gel hard and New Truliner was adversely affected by microwave disinfection, immersion in water or in sodium perborate. Microwave disinfection caused severe alterations on the surface of the resilient liner Trusoft.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21986658      PMCID: PMC3984201          DOI: 10.1590/s1678-77572011000500015

Source DB:  PubMed          Journal:  J Appl Oral Sci        ISSN: 1678-7757            Impact factor:   2.698


INTRODUCTION

Direct relining of removable dentures with hard or resilient autopolymerizing reline materials can be used as an alternative to the laboratory relining system to improve the retention and stability of the prostheses and the distribution of the masticatory forces transmitted to the underlying tissues[14,15,18]. Several studies have demonstrated the adherence of Candida spp to both denture base acrylic resins and lining materials[6,7,24,29]. Candida spp has been well-established as a primary microbial factor in the etiology of denture stomatitis[19]. Therefore, the denture fitting-surface can act as a reservoir of Candida spp[7] and the use of removable dentures is a predisposing factor for denture related stomatitis[8]. Another concern has been the continuous swallowing or aspiration of microorganisms from denture plaque[21], which may have significant implications for the general health of the patients and in cases of immunocompromised host or medicated elderly individuals. Therefore, proper routine cleaning of the denture is essential for the prevention and treatment of denture stomatitis. Studies have shown that immersion in peroxide solutions and microwave irradiation are effective methods to inactivate plaque microorganisms from removable dentures[6,11,16,19]. Ideally, a disinfection method should be effective without detrimental effects on the properties of the materials used for the fabrication and the relining of denture bases. Among these properties, roughness is important[13,15,24,25], as rough surfaces of resilient liners and acrylic resins are significantly more prone to microorganisms accumulation and plaque formation than smooth surfaces[24,25,29]. Surface roughness provides niches in which microorganisms are protected from the shear forces and oral hygiene measures, thus allowing the entrapped microbial cells time to attach irreversibly to a surface[23]. Studies have evaluated the effect of immersion solutions of the properties of denture base acrylic resins and resilient and hard relining materials, such as color[12], hardness[20], water sorption and solubility[10] and porosity[9]. With regard to microwave irradiation, the studies have been focused on the effects on hardness[15], bond strength to denture base resins[15], flexural strength[22], and residual monomer[27,28,30]. On the other hand, few studies have investigated the influence of disinfection by immersion on the surface roughness of denture base[11] and reline materials[4]. The information on the effects of microwave disinfection on this property is even more limited[26]. However, considering that repeated use of a disinfection method may cause alterations on the material's surface, thus facilitating the adhesion of microorganisms, the effect of disinfection methods on the roughness of reline materials should be further investigated. In addition, the study of Bal, et al.[5] (2008) demonstrated that temporary and permanent soft lining materials showed rapid and extensive microbial colonization on the palatal surfaces of dentures carried by volunteers in vivo. Hence, attention should be paid to biofilm control in relined dentures. This is particularly important for the temporary soft liners that have been used as essential adjuncts in prosthodontic treatment and management of traumatized oral mucosa[5]. The aim of this study was to evaluate the surface roughness of one denture base acrylic resin, three hard chairside reline resins and three resilient lining materials. The effect of disinfection by immersion in sodium perborate solution and microwave irradiation on this property was also evaluated. The null hypotheses were that the surface roughness of the denture base and the reline materials is similar and that both disinfection methods could be used without adverse effects on this property.

MATERIAL AND METHODS

The product names, codes, batch numbers, manufacturers, compositions, powder/liquid proportions, and polymerization/gelation conditions of the materials studied are listed in Figure 1. Thirty specimens of each material were made using a stainless steel mould with a breakaway compartment (12 mm×12 mm×2 mm). When the specimens were made using the heat-polymerizing acrylic resin Lucitone 550, initially silicone impression material (ZetaPlus putty, Zhermack, Badia Polesine, Rovigo, Italy) was adapted into the stainless steel mold. The silicone patterns were then invested by sandwiching them between two glass slides in Type IV stone (Troquel Quatro, Polidental Indústria e Comércio LTDA, São Paulo, SP, Brazil), using a conventional denture processing flask. The Lucitone 550 acrylic resin was proportioned, packed under pressure, and processed according to the manufacturer's instructions (Figure 1). After polymerization, the flasks were bench cooled at room temperature for 30 min and 15 min under running water before the specimens were removed from the flasks.
Figure 1

Materials used in this study

ProductCodeManufacturerPowder/liquid ratioCompositionBatch numberPolymerization/ gelation conditions
Tokuyama Rebase IITRTokuyama Dental Corp.,Tokyo, Japan2.056 g/1 mLPowder - PEMA Liquid - AAEM and 1,9-nonanediol dimethacrylateUF626948 min at room temperature
New TrulinerNTThe Bosworth Co., Skokie, IL, USA1.34 g/1 mLPowder - PEMA Liquid - IBMA and DBP0409-49510-15 min at room temperature
Ufi Gel hardUHVoco, Cuxhaven, Germany2.12 g/1.2 mLPowder - PEMA Liquid - 1,6-HDMA5718457 min at room temperature
TrusoftTThe Bosworth Co., Skokie, IL, USA1.06 g/1 mLPowder - PEMA Liquid - Alkyl phthalate (plasticizer) and ethyl alcohol0403-1635 min at room temperature
SofrelinerSTokuyama Dental Corp.,Tokyo, JapanAuto-dispensing systemPolyorganosiloxane Silicone resin powder SilicaU6846066.5 min at room temperature
DentusilDThe Bosworth Co., Skokie, IL, USAAuto-dispensing systemPolyorganosiloxane Silica702.0735 min at room temperature
Lucitone 550LDentsply Industria e Comercio Ltda., Petropolis, RJ, Brazil2.1 gm/1 mLPowder - PMMA Liquid - MMA and EDGMAP- 303758 L- 5924490 min at 73ºC and then 100ºC boiling water for 30 min

PEMA, poly (ethyl methacrylate); AAEM - 2-acetoacetoxy (ethyl) methacrylate; PMMA, poly (methyl methacrylate); IBMA, isobutyl methacrylate; DBP, di-n-butyl phthalate; 1,6-HDMA, 1,6-hexanediol dimethacrylate; MMA, (methyl methacrylate); EDGMA, (ethylene glycol dimethacrylate)

Materials used in this study PEMA, poly (ethyl methacrylate); AAEM - 2-acetoacetoxy (ethyl) methacrylate; PMMA, poly (methyl methacrylate); IBMA, isobutyl methacrylate; DBP, di-n-butyl phthalate; 1,6-HDMA, 1,6-hexanediol dimethacrylate; MMA, (methyl methacrylate); EDGMA, (ethylene glycol dimethacrylate) To obtain the specimens of the relining resins TR, NT and UH, the materials were mixed according to the manufacturers' instructions and inserted into the mold placed on an acetate sheet and a glass slab. A second acetate sheet and glass slab was placed over the material and light pressure was applied to expel excess material from the mould. When the specimens were made using the resilient liners T, S and D specimens of the denture base resin L were made as described. These specimens were then placed into a stainless steel mould with a breakaway compartment with 12 mm×12 mm×4 mm placed on the center of a glass plate. The surfaces were treated with the bonding agents supplied by the manufacturers of each resilient liner and the remaining 2.0 mm was filled with the resilient liners. This thickness was selected based on the study of Murata, et al.[17] (2008) which reported that, to be effective, a thickness of 1.5 to 2 mm of the soft liner is recommended. Material T was mixed according to the manufacturer's instructions (Figure 1). For the resilient liner S and D, the specimens were made by expressing the cartridge-mixed material directly into the mold. An acetate sheet and a second glass slab were placed over the material and light pressure was applied to expel excess material from the mould. All autopolymerizing specimens were allowed to polymerize undisturbed until their polymerization/gelation. The edges of the specimens of the denture base L and the hard chairside reline resins TR, NT and UH were carefully finished with 400-grit silicon carbide paper to remove irregularities. For the resilient liners T, S and D, the flash was trimmed with a razor blade, and the edges were smoothed with 600-grit silicon carbide paper. The surface roughness (Ra - µm) was analyzed with a surface roughness profilometer (Mitutoyo surftest SJ-401, Mitutoyo Corporation, Tokyo, Japan) with a diamond stylus (tip radius 5 µm). A reading was obtained by the needle passing across 0.8 mm length at 1 mm/s to the nearest of 0.01 µm. This procedure was repeated two more times at the same position for a total of three readings. As surface roughness was measured at four positions, radially across each specimen, a final Ra average was calculated and the means of individual specimens were averaged (baseline reading). An orientation jig was fabricated to position the stylus of the profilometer instrument to the same location on the specimen for repeated measurements[4]. For the autopolymerizing reline materials, the roughness measurements were performed within the first hour in dry condition at room temperature (23±2ºC). These values were used as controls due to the fact that the patients will be wearing the relined denture bases soon after polymerization, without any effect of water sorption and disinfection. For the resin L, the specimens were stored in distilled water at 37±2ºC for 48 hours before roughness measurements. This time was used as representative of the time elapsed between relining procedure and denture insertion, when laboratory-processed reline system is performed[4]. During this waiting time, the dentures should be immersed in water. Thereafter, the specimens of each material (n=30) were divided into three groups, according to the following experimental conditions: C = specimens were not submitted to the disinfection procedures, but kept in water at 37±2ºC for 4 weeks (control). P = specimens were submitted to daily disinfection by immersing into 3.8% sodium perborate solution at 50ºC for 8 hours at room temperature, and immersed into distilled water for the remainder of the 24 h period at 37ºC, thus simulating an overnight daily soaking[13]. For each immersion, fresh sodium perborate solution was prepared and the distilled water was changed daily. This cycle was repeated up to 4 weeks, so that the period of chemical disinfection would be comparable with that of microwave disinfection and control. MW = specimens were submitted to microwave disinfection (6 min/650 W), with the specimens immersed in 200 mL of water during irradiation. The irradiations were performed three times a week for a total of four weeks[19]. The specimens were stored in water at 37ºC between disinfection cycles. For groups C and MW, the water was changed daily. For all groups, the specimens were individually placed in 500-mL beakers and the volume of liquid (distilled water or perborate solution) used was 200 mL. This minimum volume was calculated by measuring the volume of liquid that would completely cover a maxillary complete denture in a standard denture pot[20]. The surface roughness of each specimen was measured again at 1, 3 and 28 days, using the same procedures described above. For each material, the differences between the roughness values obtained in each period and the baseline reading was then calculated and used to evaluate the changes in roughness due to the disinfection procedures or immersion in water. Baseline roughness values were analyzed by Kruskal-Wallis test to determine differences among materials. For each material, the changes in roughness (differences between the roughness values obtained in each period and the baseline reading) at the different time intervals within each group were analyzed statistically using Student's t-test. Statistical analyses were conducted at 95% level of confidence.

RESULTS

Table 1 shows the mean surface roughness values recorded at baseline and standard deviations, and the results from the Kruskal-Wallis test. At baseline, the resilient liner material T showed the highest mean surface roughness. Material S exhibited significantly higher surface roughness than the hard chairside reline resins NT and UH (P<0.001), which were not significantly different from each other (P=1.00). No significant differences were found among UH, TR, D and L, and among TR, L, D and S (P>0.05).
Table 1

Mean baseline roughness (Ra - μm) and standard deviations (SD) for all materials evaluated

MaterialMean (SD)
New Truliner (NT)0.22±0.12a
Ufi Gel hard (UH)0.23±0.12ab
Lucitone (L)0.37±0.19bc
Tokuyama Rebase II (TR)0.37±0.19bc
Dentusil (D)0.38±0.22bc
Sofreliner (S)0.49±0.17c
Trusoft (T)3.54±0.48d

Means with identical letter were not significantly different (Kruskal-Wallis; P>.05).

Mean baseline roughness (Ra - μm) and standard deviations (SD) for all materials evaluated Means with identical letter were not significantly different (Kruskal-Wallis; P>.05). Table 2 shows the results from the t-Student test for the analysis of the differences between the roughness measurements obtained at three evaluation periods (1, 3 and 28 days) and the baseline readings, for the three groups analyzed in this study. No significant changes in roughness were found for the materials TR, L, S and D during the 28 days, regardless of experimental condition evaluated (P>0.05). The resilient liner T presented significant decrease in roughness after the first day of immersing in water (P=0.019). The decrease in roughness was greater in the 3 (P=0.004) and 28 days periods (P=0.001). When immersed in sodium perborate solution, material T also showed a decrease in roughness; however, this decrease was significant in comparison to the baseline reading only after 28 days of immersion (P=0.013). The hard reline resin NT also showed significant changes in roughness. In the control group, significant increase in roughness was observed at the 3 (P=0.018) and 28 days periods (P=0.019). For the disinfected specimens, significant changes in roughness were found after the first day of disinfection by immersing into sodium perborate solution (P=0.001) or microwave irradiation (P<0.001). A significant increase in roughness of material NT was also observed at the 3 and 28 days periods (P<0.001). The reline resin UH also exhibited significantly increased roughness when immersed in water for 1, 3 and 28 days (P=0.030; P=0.041; P=.014; respectively), and in sodium perborate solution for 3 (P=0.039) and 28 days (P=0.019). When subjected to disinfection by microwave irradiation, the changes in roughness of UH specimens observed at the 1 (P<0.001) and 3-days (P=0.002) were higher than that of the 28-days period (P=0.015). Figure 2 shows Trusoft material after microwave disinfection, and Figures 3 and 4 illustrate the scanning electron microscopy (SEM) of the materials Trusoft and Sofreliner after microwave disinfection, respectively. It can be seen from Figures 2 and 3, that microwaving produced severe alterations on the surface of the material T, which impeded roughness measurements after this procedure.
Table 2

Means (SD) roughness differences relative to the baseline readings

MaterialGroup1st day 3rd day 28th day 
NTWater (C)-0.01±0.17 0.27±0.27*0.19±0.20*
 Perborate (P)0.32±0.19*0.32±0.11*0.42±0.14*
 Microwave (MW)0.52±0.13*0.56±0.12*0.76±0.22*
TRWater (C)0.02±0.23 0.06±0.30 0.03±0.31 
 Perborate (P)0.06±0.21 0.13±0.34 0.24±0.33 
 Microwave (MW)0.13±0.24 0.07±0.13 0.14±0.28 
UHWater (C)0.26±0.32*0.21±0.27*0.19±0.20*
 Perborate (P)-0.02±0.20 0.11±0.14*0.25±0.26*
 Microwave (MW)0.17±0.07*0.18±0.12*0.14±0.13*
LWater (C)0.08±0.12 0.03±0.12 0.08±0.12 
 Perborate (P)0.08±0.08 0.04±0.06 0.09±0.12 
 Microwave (MW)0.08±0.22 0.00±0.21 0.07±0.18 
SWater (C)-0.01±0.07 -0.04±0.20 -0.10±0.16 
 Perborate (P)0.02±0.05 0.03±0.17 0.06±0.31 
 Microwave (MW)0.00±0.11 -0.07±0.22 0.00±0.21 
DWater (C)-0.07±0.21 0.06±0.25 0.10±0.29 
 Perborate (P)-0.10±0.25 -0.08±0.24 -0.11±0.28 
 Microwave (MW)0.20±0.35 0.19±0.37 0.14±0.37 
TWater (C)-0.67±0.68*-0.86±0.65*-0.75±0.46*
 Perborate (P)0.10±0.40 0.08±0.54 -0.43±0.44*

Statistical difference between the roughness measurements obtained at three evaluation periods (1, 3 and 28 days) and the baseline readings (t-Student test; P < .05).

Figure 2

Trusoft material after microwave disinfection

Figure 3

Scanning electron microscopy (SEM) micrograph of material Trusoft after microwave disinfection

Figure 4

Scanning electron microscopy (SEM) micrograph of material Sofreliner after microwave disinfection

Means (SD) roughness differences relative to the baseline readings Statistical difference between the roughness measurements obtained at three evaluation periods (1, 3 and 28 days) and the baseline readings (t-Student test; P < .05). Trusoft material after microwave disinfection Scanning electron microscopy (SEM) micrograph of material Trusoft after microwave disinfection Scanning electron microscopy (SEM) micrograph of material Sofreliner after microwave disinfection

DISCUSSION

Surface roughness is an important property due to its influence on microbial adhesion[23,24,29]. The adherence of microorganisms on the surface of polymeric materials, such as denture base acrylic resins and hard and resilient liners, is the first step for the colonization and development of an oral infection in denture wearers[24]. Therefore, these materials should present the smoothest surfaces possible in order to prevent biofilm formation and oral mucosa inflammation and facilitate denture cleansing[23-25,29]. The results of the present study demonstrated that the hard reline materials presented similar (TR and UH) or lower (NT) mean initial surface roughness values compared to those of the denture base acrylic resin L. These findings may be related to the fact that the denture base and hard reline materials were processed against glass following the recommendation of Radford, et al.[25] (1998) who stated that control surfaces must be as smooth as possible. With regard the resilient lining materials, there were no significant differences between the mean values obtained for S and D and those obtained for L. However, T presented the highest initial roughness mean value (Table 1). Thus, the first null hypothesis was rejected. The manner how the resilient relining materials evaluated in this study are supplied could help explain the differences observed in their surface roughness. While material T is supplied as separate powder and liquid components that should be mixed, S and D soft liners are automatically mixed and extruded using the dual paste cartridge and dispenser system. It is possible that air bubbles incorporated to the material during mixing were clustered close to the surface, contributing to the higher roughness of T compared to the other resilient relining materials. Conversely, the use of cartridge and dispenser system probably prevented bubble formation within the S and D specimens and on their surface. The second null hypothesis that both disinfection methods could be used without adverse effects on the surface roughness of the materials was also rejected. The results showed that the relining resilient materials had different behaviors when subjected to disinfection methods evaluated, which is in agreement with the findings of previous investigations[13]. In the present study, the surface roughness of S and D materials remained unaltered regardless of the experimental conditions (Figure 4). On the other hand, the soft liner T showed a significant decrease in surface roughness when immersed in water and the differences compared to the initial roughness mean value (baseline reading) were more pronounced after longer immersion periods (Table 2). A decrease in surface roughness was also observed after disinfection with 3.8% sodium perborate, though it was less pronounced and occurred only after 28 days of immersion. Microwaving of T produced severe alterations on the material's surface, which impeded roughness measurements after this procedure (Figures 2 and 3). The different behaviors of the resilient relining materials may be partially explained by the differences in their compositions. T is a plasticized acrylic resin, which, according to its manufacturer, presents a poly(ethylmethacrylate)-based powder component and a liquid component with high concentration of a plasticizing agent (alkyl phthalate) and ethanol. Therefore, it is likely that the presence of the plasticizing agent in its composition and the viscoelastic behavior of plasticized resins[18] allowed the material to flow over time when immersed in water. It may be considered that this flow permitted the filling of porosities, irregularities and possible depressions formed on acrylic surface, resulting in lower roughness mean values[9]. In addition, two phenomena take place when plasticized resins are immersed in water: loss of plasticizing agent and water sorption[14,18]. If the sorption of water by the relining material T was greater than the loss of plasticizing agent, a volume increase might have occurred, making the surface smoother[14]. When material T was immersed in the sodium perborate solution, surface roughness also decreased, but more slowly (28 days; Table 2). It is likely that the higher ionic concentration in the sodium perborate solution compared to water resulted in greater release of soluble components[14]. However, the water sorption and solubility of this material when subjected to the same conditions evaluated in the present study should be further investigated to confirm these hypotheses. The severe alterations observed on the surface of T specimens when disinfected by microwave irradiation may be related to the temperature. During microwaving, the water in which the materials are immersed reached the boiling temperature after approximately 1 minute and 30 seconds and remained at this temperature up to the end of the microwaving cycle. It is possible that the heating of T during microwave disinfection has favored the diffusion and release of soluble components and accelerated the aging process[1]. Conversely, in silicone-based relining materials, such as S and D (polyorganosiloxanes), the polymer is an elastomer and does not need external plasticizing agents[15]. Furthermore, the polymer chains in S and D are formed by addition reaction and thus no byproduct is formed[18]. It has been demonstrated that silicone-based resilient materials polymerized by addition reaction remain stable during water storage for long periods[18]. Therefore, the lack of significant effects of the disinfection methods on the surface roughness of S and D may be partially attributed to the favorable characteristics of water sorption and solubility of these resilient relining materials. Jin, et al.[13] (2003) have also found that, in general, silicone-based resilient materials were more stable regarding surface roughness and color change than the plasticized resins. Concerning the hard reline materials, the most significant alterations were observed for NT. Among the hard relining materials evaluated in this study, NT has the highest liquid/powder mixing ratio, and this might have resulted in the presence of a larger number of residual monomer molecules in the polymerized resin[28]. In addition, NT also presents a plasticizing agent (di-n-butyl phthalate) in its composition[27]. The release of these residual monomer molecules and the plasticizing agent might have contributed to alter the surface characteristics of the material, increasing its surface roughness. This release might have been facilitated by the ionic concentration of the sodium perborate solution[14] and by the temperature of the water during microwave disinfection[27], which could partially explain the more significant alterations observed after use of both disinfection methods compared to the control (immersion water). The results also showed that the surface roughness of the denture base acrylic resin L and the hard reline material TR was not affected by their immersion in water and neither by the disinfection methods evaluated in this study. These results are similar to those reported by Harrison, et al.[11] (2004), and may be related to the type of polymerization of the materials. Heat-polymerized materials, such as L, present a higher monomer-to-polymer conversion rate and lower residual monomer content[27,28]. Although the hard reline TR material is an autopolymerized resin, it contains the monomer 2-acetoacetoxyethyl methacrylate, which has been used in experimental materials to increase the polymerization rate due to its molecular structure and higher reactivity[30]. This monomer presents a longer lateral chain and several reactive centers, which provide a more complete polymerization. In addition, L and TR contain crosslinking agents in their compositions (ethylene glycol dimethacrylate and 1,9-nonanediol dimethacrylate, respectively), which may have contributed to the formation of more dense and stable polymer structures[2,3]. This may have contributed to the absence of significant effect on the surface roughness of these materials after immersion in water or disinfection. The alterations observed in the surface roughness of the reline resin UH were not expected because this material also has a high concentration of the crosslinking agent 1,6-hexanediol dimethacrylate. Due to the greater distance between the methacrylate groups, this crosslinking agent also presents a more reactive second group[27,28], thus favoring the monomer-to-polymer conversion. Nevertheless, it has been demonstrated that UH material showed significantly higher residual monomer content and release than a reline resin with similar composition (Tokuso Rebase Fast)[28]. The goal of subjecting dentures to disinfection by immersion in a sodium perborate solution or microwave irradiation is controlling the biofilm formed on the acrylic surface. Nevertheless, if the repeated use of a disinfection method causes significant alterations on the material's surface, this goal is not achieved because the increase in the surface roughness may favor the adhesion of microorganisms. It is important to emphasize, however, that the influence of the changes in surface roughness observed in the present study on the adherence of microorganisms to the reline materials was not investigated. In addition, surface roughness is not the only factor involved in the adhesion of microorganisms to polymer-based materials[21]. The presence of salivary pellicle and the surface free energy have been also reported to influence the adhesion of microorganisms[23]. Others factors such as wettability, hydrophobicity and electrostatic interactions of materials used in prosthodontics may also influence the microbial retention[29]. These are limitations of the present study and should be considered in further investigations. Despite these limitations, the findings presented here demonstrated that immersion in sodium perborate and microwave irradiation may not be seen as a general recommendation for denture disinfection, since it may increase the surface roughness of some materials used for relining dentures, as observed previously[6]. This may help dental practitioners instructing their patients regarding the most effective methods for biofilm control, according to the type of relining material used in their dentures.

CONCLUSION

Within the limitations of this study the following conclusions were drawn: In all conditions evaluated, the resilient relining material T presented the highest surface roughness mean values. There were no significant differences in the surface roughness of the denture base resin L and the relining materials TR, S and D under the conditions evaluated. T presented a significant decrease in surface roughness after immersion in water or in a 3.8% sodium perborate solution; microwave disinfection caused severe alterations on the surface of this material. NT and UH reline resins showed significant increase of surface roughness after immersion in water or disinfection, and more pronounced effects were observed for New Truliner after microwave disinfection.
  29 in total

1.  Comparative study of water sorption and solubility of soft lining materials in the different solutions.

Authors:  Nuran Dinçkal Yanikoglu; Zeynep Yeşil Duymuş
Journal:  Dent Mater J       Date:  2004-06       Impact factor: 2.102

2.  Effect of microwave disinfection on denture base adaptation and resin surface roughness.

Authors:  Evandro Afonso Sartori; Caroline Bom Schmidt; Luiz Fernando Walber; Rosemary Sadami Arai Shinkai
Journal:  Braz Dent J       Date:  2006

3.  A pilot study to evaluate the adhesion of oral microorganisms to temporary soft lining materials.

Authors:  Bilge T Bal; Hüsnü Yavuzyilmaz; Mihriban Yücel
Journal:  J Oral Sci       Date:  2008-03       Impact factor: 1.556

4.  Properties of highly cross-linked autopolymerizing reline acrylic resins.

Authors:  T Arima; H Murata; T Hamada
Journal:  J Prosthet Dent       Date:  1995-01       Impact factor: 3.426

5.  The compatibility of tissue conditioners with denture cleaners and chlorhexidine.

Authors:  J C Davenport; H J Wilson; R M Basker
Journal:  J Dent       Date:  1978-09       Impact factor: 4.379

6.  Soft lining materials: their absorption of, and solubility in, artificial saliva.

Authors:  M N Kazanji; A C Watkinson
Journal:  Br Dent J       Date:  1988-08-06       Impact factor: 1.626

Review 7.  The influence of surface roughness and surface-free energy on supra- and subgingival plaque formation in man. A review of the literature.

Authors:  M Quirynen; C M Bollen
Journal:  J Clin Periodontol       Date:  1995-01       Impact factor: 8.728

8.  Influence of denture cleansers on the color stability of three types of denture base acrylic resin.

Authors:  Guang Hong; Hiroshi Murata; YingAi Li; Sinshuke Sadamori; Taizo Hamada
Journal:  J Prosthet Dent       Date:  2009-03       Impact factor: 3.426

9.  An in vitro study into the effect of a limited range of denture cleaners on surface roughness and removal of Candida albicans from conventional heat-cured acrylic resin denture base material.

Authors:  Z Harrison; A Johnson; C W I Douglas
Journal:  J Oral Rehabil       Date:  2004-05       Impact factor: 3.837

10.  Effect of water-bath post-polymerization on the mechanical properties, degree of conversion, and leaching of residual compounds of hard chairside reline resins.

Authors:  Vanessa M Urban; Ana L Machado; Carlos E Vergani; Eunice T Giampaolo; Ana C Pavarina; Fernando G de Almeida; Quezia B Cass
Journal:  Dent Mater       Date:  2009-01-10       Impact factor: 5.304

View more
  6 in total

1.  The effect of mechanical and chemical polishing techniques on the surface roughness of heat-polymerized and visible light-polymerized acrylic denture base resins.

Authors:  Abdul Aziz Abdullah Al-Kheraif
Journal:  Saudi Dent J       Date:  2014-02-03

2.  Randomized clinical evaluation of a light-cured base material for complete dentures.

Authors:  Franz Sebastian Schwindling; Wolfgang Bömicke; Alexander J Hassel; Peter Rammelsberg; Thomas Stober
Journal:  Clin Oral Investig       Date:  2013-09-21       Impact factor: 3.573

3.  Antimicrobial Activity of Cold Plasma Treatment on Acrylic Denture Bases: An In Vitro Evaluation.

Authors:  Mohammad Asnaashari; Salar Motamedi; Negin Asnaashari; Saranaz Azari-Marhabi
Journal:  J Lasers Med Sci       Date:  2019-12-01

4.  The Beneficial Effect of Equisetum giganteum L. against Candida Biofilm Formation: New Approaches to Denture Stomatitis.

Authors:  Rafaela A S Alavarce; Luiz L Saldanha; Nara Ligia M Almeida; Vinicius C Porto; Anne L Dokkedal; Vanessa S Lara
Journal:  Evid Based Complement Alternat Med       Date:  2015-07-28       Impact factor: 2.629

5.  Effect of denture cleansers on color stability, surface roughness, and hardness of different denture base resins.

Authors:  Anand Porwal; Meenakshi Khandelwal; Vikas Punia; Vivek Sharma
Journal:  J Indian Prosthodont Soc       Date:  2017 Jan-Mar

6.  Denture Liners: A Systematic Review Relative to Adhesion and Mechanical Properties.

Authors:  Simone Kreve; Andréa C Dos Reis
Journal:  ScientificWorldJournal       Date:  2019-03-03
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.