STATEMENT OF PROBLEM: Microwave irradiation has been suggested for denture disinfection. However, the effect of this procedure on the hardness and bond strength between resilient liners and denture base acrylic resin is not known.
PURPOSE: This study evaluated the effect of water storage time and microwave disinfection on the hardness and peel bond strength of 2 silicone resilient lining materials to a heat-polymerized acrylic resin.
MATERIAL AND METHODS: Acrylic resin (Lucitone 199) specimens (75 x 10 x 3 mm) were stored in water at 37 degrees C (2 or 30 days) before bonding (n = 160). The resilient lining materials (GC Reline Extra Soft and Dentusil) were bonded to the denture base and divided into the following 4 groups (n = 10): Tests performed immediately after bonding (control); specimens immersed in water (200 mL) and irradiated twice, with 650 W for 6 minutes; specimens irradiated daily for 7 total cycles of disinfection; specimens immersed in water (37 degrees C) for 7 days. Specimens were submitted to a 180-degree peel test (at a crosshead speed of 10 mm/min) and the failure values (MPa) and mode of failure were recorded. Pretreatment and posttreatment hardness measurements (Shore A) of the resilient materials were also performed. Three-way analysis of variance, followed by the Tukey HSD test, was performed (alpha = .05).
RESULTS: The analysis revealed that, for all conditions, the mean failure strengths of GC Reline Extra Soft (0.95-1.19 MPa) were significantly higher ( P < .001) than those of Dentusil (0.45-0.50 MPa). The adhesion of the liners was not adversely affected by water storage time of Lucitone 199 or microwave disinfection. All peel test failures were cohesive. There was a small but significant difference ( P < .001) between the pretreatment (34.33 Shore A) and posttreatment (38.69 Shore A) hardness measurements.
CONCLUSION: Microwave disinfection did not compromise the hardness of either resilient liners or their adhesion to the denture base resin Lucitone 199.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16046971     DOI: 10.1016/j.prosdent.2005.04.017

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  16 in total

1.  Anular delamination strength of human lumbar intervertebral disc.

Authors:  Diane E Gregory; Won C Bae; Robert L Sah; Koichi Masuda
Journal:  Eur Spine J       Date:  2012-05-01       Impact factor: 3.134

2.  Tensile bond strength of silicone-based soft denture liner to two chemically different denture base resins after various surface treatments.

Authors:  Hakan Akin; Faik Tugut; Umit Guney; Omer Kirmali; Turker Akar
Journal:  Lasers Med Sci       Date:  2012-03-25       Impact factor: 3.161

Review 3.  The Effect of Microwave Disinfection on Denture Base Polymers, Liners and Teeth: A Basic Overview.

Authors:  Theodoros Klironomos; Aspasia Katsimpali; Gregory Polyzois
Journal:  Acta Stomatol Croat       Date:  2015-09

4.  Effect of different surface treatments on tensile bond strength of silicone-based soft denture liner.

Authors:  Hakan Akin; Faik Tugut; Burcu Mutaf; Gulsah Akin; A Kemal Ozdemir
Journal:  Lasers Med Sci       Date:  2010-08-21       Impact factor: 3.161

5.  Strength of the bond between a silicone lining material and denture resin after Er:YAG laser treatments with different pulse durations and levels of energy.

Authors:  Faik Tugut; Hakan Akin; Burcu Mutaf; Gulsah Emine Akin; Ali Kemal Ozdemir
Journal:  Lasers Med Sci       Date:  2010-12-14       Impact factor: 3.161

6.  Evaluation of effectiveness of microwave irradiation for disinfection of silicone elastomeric impression material.

Authors:  Abhilasha Bhasin; V Vinod; Vinny Bhasin; Xavier Mathew; Suresh Sajjan; Syed Tauqheer Ahmed
Journal:  J Indian Prosthodont Soc       Date:  2013-01-22

7.  Changes in roughness of denture base and reline materials by chemical disinfection or microwave irradiation: surface roughness of denture base and reline materials.

Authors:  Ana Lucia Machado; Eunice Teresinha Giampaolo; Carlos Eduardo Vergani; Juliana Feltrin de Souza; Janaina Habib Jorge
Journal:  J Appl Oral Sci       Date:  2011-10       Impact factor: 2.698

8.  Peel strength of denture liner to PMMA and polyamide: laser versus air-abrasion.

Authors:  Fatih Mehmet Korkmaz; Bora Bagis; Mutlu Ozcan; Rukiye Durkan; Sedanur Turgut; Sabit Melih Ates
Journal:  J Adv Prosthodont       Date:  2013-08-31       Impact factor: 1.904

9.  Effect of denture cleansers on surface hardness of resilient denture liners at various time intervals- an in vitro study.

Authors:  Rasleen Kaur Pahuja; Sandeep Garg; Sanjay Bansal; Rajat Harvinder Dang
Journal:  J Adv Prosthodont       Date:  2013-08-31       Impact factor: 1.904

10.  Peel bond strength of resilient liner modified by the addition of antimicrobial agents to denture base acrylic resin.

Authors:  Cristiane S Alcântara; Allana F C de Macêdo; Bruno C V Gurgel; Janaina H Jorge; Karin H Neppelenbroek; Vanessa M Urban
Journal:  J Appl Oral Sci       Date:  2012 Nov-Dec       Impact factor: 2.698

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.