Literature DB >> 21984313

Aseptic loosening of total hip replacement presenting as an anterior thigh mass.

Ravindra Gudena1, Suma Kuna, Nikhil Pradhan.   

Abstract

Aseptic loosening is one of the commonest complications of total hip replacement that can cause pain and instability. The chronic inflammatory response to the wear debris from the polyethylene or metal can cause osteolysis and implant failure. We report a case of aseptic loosening of the hip, presented with a swelling over the anterior thigh without any pain or instability in the joint. This mass was a foreign body granuloma formed secondary to the polyethylene wear debris due to the instability of the polyethylene in the metal shell. The patient underwent successful revision hip arthroplasty after the removal of the foreign body granuloma.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21984313     DOI: 10.1007/s12306-011-0167-y

Source DB:  PubMed          Journal:  Musculoskelet Surg        ISSN: 2035-5114


  10 in total

1.  Motion at the modular acetabular shell and liner interface. A comparative study.

Authors:  T K Fehring; S E Smith; E R Braun; C Mobley; P L Wang; W L Griffin
Journal:  Clin Orthop Relat Res       Date:  1999-10       Impact factor: 4.176

2.  Revision of well-fixed cementless acetabular components for polyethylene failure.

Authors:  Christopher L Peters; Jill A Erickson; Harold K Dunn
Journal:  Clin Orthop Relat Res       Date:  2003-09       Impact factor: 4.176

3.  An intrapelvic granuloma induced by acetabular cup loosening.

Authors:  A Reigstad; M Røkkum
Journal:  Acta Orthop Scand       Date:  1992-08

4.  Wear Debris in Total Joint Replacements.

Authors: 
Journal:  J Am Acad Orthop Surg       Date:  1994-07       Impact factor: 3.020

5.  Iliopsoas bursal distension caused by acetabular loosening after total hip arthroplasty. A rare complication of total hip arthroplasty.

Authors:  K Matsumoto; S Hukuda; J Nishioka; T Fujita
Journal:  Clin Orthop Relat Res       Date:  1992-06       Impact factor: 4.176

Review 6.  The generation of wear debris from cementless hip prostheses.

Authors:  J P Collier; M B Mayor; V A Surprenant; M Wrona; H P Surprenant; I R Williams
Journal:  Instr Course Lect       Date:  1994

7.  Pelvic mass caused by polyethylene wear after uncemented total hip arthroplasty.

Authors:  J W Wang; C C Lin
Journal:  J Arthroplasty       Date:  1996-08       Impact factor: 4.757

8.  Long-term registration has improved the quality of hip replacement: a review of the Swedish THR Register comparing 160,000 cases.

Authors:  P Herberts; H Malchau
Journal:  Acta Orthop Scand       Date:  2000-04

9.  Pelvic mass causing vesical compression after total hip arthroplasty. Case report.

Authors:  S J Hattrup; R S Bryan; T A Gaffey; C R Stanhope
Journal:  Clin Orthop Relat Res       Date:  1988-02       Impact factor: 4.176

Review 10.  Mechanisms of bone loss associated with total hip replacement.

Authors:  J J Jacobs; D R Sumner; J O Galante
Journal:  Orthop Clin North Am       Date:  1993-10       Impact factor: 2.472

  10 in total
  1 in total

Review 1.  Fracture of ceramic bearing surfaces following total hip replacement: a systematic review.

Authors:  Francesco Traina; Marcello De Fine; Alberto Di Martino; Cesare Faldini
Journal:  Biomed Res Int       Date:  2013-06-13       Impact factor: 3.411

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.