Literature DB >> 10709011

Wear Debris in Total Joint Replacements.

.   

Abstract

In vivo degradation of prosthetic implant materials is increasingly recognized as a major factor limiting the durability of total joint arthroplasty. In vivo degradation occurs primarily by means of wear processes that can generate large quantities of particulate debris. This debris can stimulate an adverse local host response leading to periprosthetic bone loss, which can compromise implant fixation and bone stock. The authors review the basic mechanisms of implant degradation and the host response to particulate degradation products, particularly in the context of the pathogenesis of osteolysis. Submicron polyethylene particles (mean size, 0.5 um) are the dominant type of wear particle present in periprosthetic tissues associated with uncemented hip replacements. Polyethylene wear can be minimized by improving the quality of the polyethylene, avoiding use of large-diameter (greater than 28 mm) femoral heads in total hip arthroplasty, and improving the design and fabrication of modular connections, which can be important sources of three-body wear particles. Advances in the understanding of the basic mechanisms of osteolysis are critical to the development of preventive measures that will minimize the clinical impact of this phenomenon.

Entities:  

Year:  1994        PMID: 10709011     DOI: 10.5435/00124635-199407000-00004

Source DB:  PubMed          Journal:  J Am Acad Orthop Surg        ISSN: 1067-151X            Impact factor:   3.020


  29 in total

1.  Expression of epidermal growth factor and transforming growth factor alpha in interfacial membranes retrieved at revision total hip arthroplasty.

Authors:  J W Xu; J Ma; T F Li; E Waris; A Alberty; S Santavirta; Y T Konttinen
Journal:  Ann Rheum Dis       Date:  2000-10       Impact factor: 19.103

2.  Aseptic loosening of total hip replacement presenting as an anterior thigh mass.

Authors:  Ravindra Gudena; Suma Kuna; Nikhil Pradhan
Journal:  Musculoskelet Surg       Date:  2011-10-09

3.  In vitro reactivity to implant metals demonstrates a person-dependent association with both T-cell and B-cell activation.

Authors:  Nadim James Hallab; Marco Caicedo; Rachel Epstein; Kyron McAllister; Joshua J Jacobs
Journal:  J Biomed Mater Res A       Date:  2010-02       Impact factor: 4.396

4.  Early dislocation rate in ceramic-on-ceramic total hip arthroplasty.

Authors:  Kenny Mai; Mary E Hardwick; Richard H Walker; Steven N Copp; Kace A Ezzet; Clifford W Colwell
Journal:  HSS J       Date:  2008-02

5.  Short-keeled cemented tibial components show an increased risk for aseptic loosening.

Authors:  Christian Ries; Markus Heinichen; Florian Dietrich; Eike Jakubowitz; Christian Sobau; Christian Heisel
Journal:  Clin Orthop Relat Res       Date:  2012-10-05       Impact factor: 4.176

6.  [Thirteen-year results for the CLS expansion cup in primary hip arthroplasty].

Authors:  D Kendoff; C Strobel; C Krettek; T Gerich
Journal:  Unfallchirurg       Date:  2006-06       Impact factor: 1.000

7.  Frank Stinchfield Award: Identification of the At-risk Genotype for Development of Pseudotumors Around Metal-on-metal THAs.

Authors:  Brett K J Kilb; Andrew P Kurmis; Michael Parry; Karen Sherwood; Paul Keown; Bassam A Masri; Clive P Duncan; Donald S Garbuz
Journal:  Clin Orthop Relat Res       Date:  2018-02       Impact factor: 4.176

8.  Sciatic nerve compression by an extrapelvic cyst secondary to wear debris after a cementless total hip arthroplasty: A case report and literature review.

Authors:  Murat Mert; Yusuf Oztürkmen; Ethem Ayhan Unkar; Sinan Erdoğan; Onat Uzümcügil
Journal:  Int J Surg Case Rep       Date:  2013-07-29

9.  Receptor activator of nuclear factor kappaB ligand (RANKL)/osteoprotegerin (OPG) ratio is increased in severe osteolysis.

Authors:  Eva Grimaud; Luc Soubigou; Séverine Couillaud; Patrick Coipeau; Anne Moreau; Norbert Passuti; François Gouin; Françoise Redini; Dominique Heymann
Journal:  Am J Pathol       Date:  2003-11       Impact factor: 4.307

10.  Wear debris pseudotumor following total knee arthroplasty: a case report.

Authors:  Andreas F Mavrogenis; George N Nomikos; Vasileios I Sakellariou; George I Karaliotas; Panayiotis Kontovazenitis; Panayiotis J Papagelopoulos
Journal:  J Med Case Rep       Date:  2009-11-29
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.