Literature DB >> 12966286

Revision of well-fixed cementless acetabular components for polyethylene failure.

Christopher L Peters1, Jill A Erickson, Harold K Dunn.   

Abstract

The results of revision of well-fixed Porous Coated Anatomic cementless acetabular components for polyethylene failure or periacetabular osteolysis in 18 hips (14 patients) are reported. Revisions were done with larger diameter cementless acetabular components replacing one-piece Porous Coated Anatomic devices for which no replacement liner was available. The objective was to determine the increase in size of the revision acetabular component and to assess clinical and radiographic outcomes. The Porous Coated Anatomic components were in place for an average of 7.8 years. At an average followup of 68 months, all revision components remain in place. Preoperatively, 12 hips in 10 patients had radiographic osteolysis, and 25 osteolytic lesions in 17 patients were grafted at revision. All grafted lesions showed partial or complete evidence of bone graft consolidation. The average revision component size increased 8.5 mm in diameter (range, 3-14 mm) compared with the primary component size. This corresponded to an average 6.5-mm increase in the acetabular cavitary diameter. When locking mechanism failure in a well-fixed cementless acetabular component prevents polyethylene liner replacement, acetabular component revision can provide good clinical and radiographic results with acceptable bone loss and improved access to osteolytic areas for debridement and grafting.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12966286     DOI: 10.1097/01.blo.0000079271.91782.6a

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  3 in total

1.  Aseptic loosening of total hip replacement presenting as an anterior thigh mass.

Authors:  Ravindra Gudena; Suma Kuna; Nikhil Pradhan
Journal:  Musculoskelet Surg       Date:  2011-10-09

2.  Retention of a well-fixed acetabular component in the setting of acetabular osteolysis.

Authors:  Pengde Kang; Jing Yang; Zongke Zhou; Bin Shen; Fuxing Pei
Journal:  Int Orthop       Date:  2012-02-21       Impact factor: 3.075

3.  A three-dimensional method for evaluating changes in acetabular osteolytic lesions in response to treatment.

Authors:  Hiroshi Egawa; Henry Ho; Cathy Huynh; Robert H Hopper; C Anderson Engh; Charles A Engh
Journal:  Clin Orthop Relat Res       Date:  2009-08-22       Impact factor: 4.176

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.