Literature DB >> 21981344

Theoretical design and analysis of multivolume digital assays with wide dynamic range validated experimentally with microfluidic digital PCR.

Jason E Kreutz1, Todd Munson, Toan Huynh, Feng Shen, Wenbin Du, Rustem F Ismagilov.   

Abstract

This paper presents a protocol using theoretical methods and free software to design and analyze multivolume digital PCR (MV digital PCR) devices; the theory and software are also applicable to design and analysis of dilution series in digital PCR. MV digital PCR minimizes the total number of wells required for "digital" (single molecule) measurements while maintaining high dynamic range and high resolution. In some examples, multivolume designs with fewer than 200 total wells are predicted to provide dynamic range with 5-fold resolution similar to that of single-volume designs requiring 12,000 wells. Mathematical techniques were utilized and expanded to maximize the information obtained from each experiment and to quantify performance of devices and were experimentally validated using the SlipChip platform. MV digital PCR was demonstrated to perform reliably, and results from wells of different volumes agreed with one another. No artifacts due to different surface-to-volume ratios were observed, and single molecule amplification in volumes ranging from 1 to 125 nL was self-consistent. The device presented here was designed to meet the testing requirements for measuring clinically relevant levels of HIV viral load at the point-of-care (in plasma, <500 molecules/mL to >1,000,000 molecules/mL), and the predicted resolution and dynamic range was experimentally validated using a control sequence of DNA. This approach simplifies digital PCR experiments, saves space, and thus enables multiplexing using separate areas for each sample on one chip, and facilitates the development of new high-performance diagnostic tools for resource-limited applications. The theory and software presented here are general and are applicable to designing and analyzing other digital analytical platforms including digital immunoassays and digital bacterial analysis. It is not limited to SlipChip and could also be useful for the design of systems on platforms including valve-based and droplet-based platforms. In a separate publication by Shen et al. (J. Am. Chem. Soc., 2011, DOI: 10.1021/ja2060116), this approach is used to design and test digital RT-PCR devices for quantifying RNA.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21981344      PMCID: PMC3216679          DOI: 10.1021/ac201658s

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  60 in total

Review 1.  Real-time PCR in clinical microbiology: applications for routine laboratory testing.

Authors:  M J Espy; J R Uhl; L M Sloan; S P Buckwalter; M F Jones; E A Vetter; J D C Yao; N L Wengenack; J E Rosenblatt; F R Cockerill; T F Smith
Journal:  Clin Microbiol Rev       Date:  2006-01       Impact factor: 26.132

2.  Digital readout of target binding with attomole detection limits via enzyme amplification in femtoliter arrays.

Authors:  David M Rissin; David R Walt
Journal:  J Am Chem Soc       Date:  2006-05-17       Impact factor: 15.419

Review 3.  Reactions in droplets in microfluidic channels.

Authors:  Helen Song; Delai L Chen; Rustem F Ismagilov
Journal:  Angew Chem Int Ed Engl       Date:  2006-11-13       Impact factor: 15.336

4.  Application of Statistics to Problems in Bacteriology: I. A Means of Determining Bacterial Population by the Dilution Method.

Authors:  H O Halvorson; N R Ziegler
Journal:  J Bacteriol       Date:  1933-02       Impact factor: 3.490

5.  Estimation of bacterial densities by means of the "most probable number".

Authors:  W G COCHRAN
Journal:  Biometrics       Date:  1950-06       Impact factor: 2.571

6.  Statistical significance and statistical power in hypothesis testing.

Authors:  R L Lieber
Journal:  J Orthop Res       Date:  1990-03       Impact factor: 3.494

7.  Droplet-based microfluidic systems for high-throughput single DNA molecule isothermal amplification and analysis.

Authors:  Linas Mazutis; Ali Fallah Araghi; Oliver J Miller; Jean-Christophe Baret; Lucas Frenz; Agnes Janoshazi; Valérie Taly; Benjamin J Miller; J Brian Hutchison; Darren Link; Andrew D Griffiths; Michael Ryckelynck
Journal:  Anal Chem       Date:  2009-06-15       Impact factor: 6.986

8.  Comparison of most probable number-PCR and most probable number-foci detection method for quantifying infectious Cryptosporidium parvum oocysts in environmental samples.

Authors:  Christine M Carey; Hung Lee; Jack T Trevors
Journal:  J Microbiol Methods       Date:  2006-05-30       Impact factor: 2.363

Review 9.  Monitoring of minimal residual disease in acute myeloid leukemia.

Authors:  Wolfgang Kern; Claudia Schoch; Torsten Haferlach; Susanne Schnittger
Journal:  Crit Rev Oncol Hematol       Date:  2005-10-05       Impact factor: 6.312

10.  Mathematical analysis of copy number variation in a DNA sample using digital PCR on a nanofluidic device.

Authors:  Simant Dube; Jian Qin; Ramesh Ramakrishnan
Journal:  PLoS One       Date:  2008-08-06       Impact factor: 3.240

View more
  35 in total

1.  Lack of correlation between reaction speed and analytical sensitivity in isothermal amplification reveals the value of digital methods for optimization: validation using digital real-time RT-LAMP.

Authors:  Eugenia M Khorosheva; Mikhail A Karymov; David A Selck; Rustem F Ismagilov
Journal:  Nucleic Acids Res       Date:  2015-09-10       Impact factor: 16.971

Review 2.  Slip-driven microfluidic devices for nucleic acid analysis.

Authors:  Weiyuan Lyu; Mengchao Yu; Haijun Qu; Ziqing Yu; Wenbin Du; Feng Shen
Journal:  Biomicrofluidics       Date:  2019-07-12       Impact factor: 2.800

Review 3.  The Future of Digital Polymerase Chain Reaction in Virology.

Authors:  Matthijs Vynck; Wim Trypsteen; Olivier Thas; Linos Vandekerckhove; Ward De Spiegelaere
Journal:  Mol Diagn Ther       Date:  2016-10       Impact factor: 4.074

4.  Microfluidics for single-cell genetic analysis.

Authors:  A M Thompson; A L Paguirigan; J E Kreutz; J P Radich; D T Chiu
Journal:  Lab Chip       Date:  2014-09-07       Impact factor: 6.799

5.  Control of initiation, rate, and routing of spontaneous capillary-driven flow of liquid droplets through microfluidic channels on SlipChip.

Authors:  Rebecca R Pompano; Carol E Platt; Mikhail A Karymov; Rustem F Ismagilov
Journal:  Langmuir       Date:  2012-01-10       Impact factor: 3.882

6.  Multiplexed quantification of nucleic acids with large dynamic range using multivolume digital RT-PCR on a rotational SlipChip tested with HIV and hepatitis C viral load.

Authors:  Feng Shen; Bing Sun; Jason E Kreutz; Elena K Davydova; Wenbin Du; Poluru L Reddy; Loren J Joseph; Rustem F Ismagilov
Journal:  J Am Chem Soc       Date:  2011-10-13       Impact factor: 15.419

7.  Statistical Analysis of Nonuniform Volume Distributions for Droplet-Based Digital PCR Assays.

Authors:  Gloria S Yen; Bryant S Fujimoto; Thomas Schneider; Jason E Kreutz; Daniel T Chiu
Journal:  J Am Chem Soc       Date:  2019-01-15       Impact factor: 15.419

8.  Mechanistic evaluation of the pros and cons of digital RT-LAMP for HIV-1 viral load quantification on a microfluidic device and improved efficiency via a two-step digital protocol.

Authors:  Bing Sun; Feng Shen; Stephanie E McCalla; Jason E Kreutz; Mikhail A Karymov; Rustem F Ismagilov
Journal:  Anal Chem       Date:  2013-01-16       Impact factor: 6.986

9.  Comparison of droplet digital PCR to real-time PCR for quantitative detection of cytomegalovirus.

Authors:  R T Hayden; Z Gu; J Ingersoll; D Abdul-Ali; L Shi; S Pounds; A M Caliendo
Journal:  J Clin Microbiol       Date:  2012-12-05       Impact factor: 5.948

10.  Increased robustness of single-molecule counting with microfluidics, digital isothermal amplification, and a mobile phone versus real-time kinetic measurements.

Authors:  David A Selck; Mikhail A Karymov; Bing Sun; Rustem F Ismagilov
Journal:  Anal Chem       Date:  2013-11-07       Impact factor: 6.986

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.