Literature DB >> 21971079

A SiPM-based isotropic-3D PET detector X'tal cube with a three-dimensional array of 1 mm(3) crystals.

Taiga Yamaya1, Takayuki Mitsuhashi, Takahiro Matsumoto, Naoko Inadama, Fumihiko Nishikido, Eiji Yoshida, Hideo Murayama, Hideyuki Kawai, Mikio Suga, Mitsuo Watanabe.   

Abstract

We are developing a novel, general purpose isotropic-3D PET detector X'tal cube which has high spatial resolution in all three dimensions. The research challenge for this detector is implementing effective detection of scintillation photons by covering six faces of a segmented crystal block with silicon photomultipliers (SiPMs). In this paper, we developed the second prototype of the X'tal cube for a proof-of-concept. We aimed at realizing an ultimate detector with 1.0 mm(3) cubic crystals, in contrast to our previous development using 3.0 mm(3) cubic crystals. The crystal block was composed of a 16 × 16 × 16 array of lutetium gadolinium oxyorthosilicate (LGSO) crystals 0.993 × 0.993 × 0.993 mm(3) in size. The crystals were optically glued together without inserting any reflector inside and 96 multi-pixel photon counters (MPPCs, S10931-50P, i.e. six faces each with a 4 × 4 array of MPPCs), each having a sensitive area of 3.0 × 3.0 mm(2), were optically coupled to the surfaces of the crystal block. Almost all 4096 crystals were identified through Anger-type calculation due to the finely adjusted reflector sheets inserted between the crystal block and light guides. The reflector sheets, which formed a belt of 0.5 mm width, were placed to cover half of the crystals of the second rows from the edges in order to improve identification performance of the crystals near the edges. Energy resolution of 12.7% was obtained at 511 keV with almost uniform light output for all crystal segments thanks to the effective detection of the scintillation photons.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21971079     DOI: 10.1088/0031-9155/56/21/003

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  10 in total

1.  Intrinsic spatial resolution evaluation of the X'tal cube PET detector based on a 3D crystal block segmented by laser processing.

Authors:  Eiji Yoshida; Hideaki Tashima; Naoko Inadama; Fumihiko Nishikido; Takahiro Moriya; Tomohide Omura; Mitsuo Watanabe; Hideo Murayama; Taiga Yamaya
Journal:  Radiol Phys Technol       Date:  2012-07-11

2.  Simulation study optimizing the number of photodetection faces for the X'tal cube PET detector with separated crystal segments.

Authors:  Takahiro Matsumoto; Taiga Yamaya; Eiji Yoshida; Fumihiko Nishikido; Naoko Inadama; Hideo Murayama; Mikio Suga
Journal:  Radiol Phys Technol       Date:  2013-08-09

Review 3.  Innovations in Instrumentation for Positron Emission Tomography.

Authors:  Eric Berg; Simon R Cherry
Journal:  Semin Nucl Med       Date:  2018-03-12       Impact factor: 4.446

4.  Modularized compact positron emission tomography detector for rapid system development.

Authors:  Daoming Xi; Xiang Liu; Chen Zeng; Wei Liu; Yanzhao Li; Yuexuan Hua; Xiongze Mei; Heejong Kim; Peng Xiao; Chien-Min Kao; Qingguo Xie
Journal:  J Med Imaging (Bellingham)       Date:  2016-12-20

5.  Efficient one-pair experimental system for spatial resolution demonstration of prototype PET detectors.

Authors:  Hideaki Tashima; Eiji Yoshida; Yoshiyuki Hirano; Fumihiko Nishikido; Naoko Inadama; Hideo Murayama; Taiga Yamaya
Journal:  Radiol Phys Technol       Date:  2014-06-18

6.  A time-based single transmission-line readout with position multiplexing.

Authors:  Minseok Yi; Jae Sung Lee
Journal:  Biomed Eng Lett       Date:  2022-01-17

7.  Development of a prototype PET scanner with depth-of-interaction measurement using solid-state photomultiplier arrays and parallel readout electronics.

Authors:  Yiping Shao; Xishan Sun; Kejian A Lan; Chad Bircher; Kai Lou; Zhi Deng
Journal:  Phys Med Biol       Date:  2014-02-20       Impact factor: 3.609

8.  GPU-based optical propagation simulator of a laser-processed crystal block for the X'tal cube PET detector.

Authors:  Yuma Ogata; Takashi Ohnishi; Takahiro Moriya; Naoko Inadama; Fumihiko Nishikido; Eiji Yoshida; Hideo Murayama; Taiga Yamaya; Hideaki Haneishi
Journal:  Radiol Phys Technol       Date:  2013-07-30

9.  Investigation of Crystal Surface Finish and Geometry on Single LYSO Scintillator Detector Performance for Depth-of-Interaction Measurement with Silicon Photomultipliers.

Authors:  Chad Bircher; Yiping Shao
Journal:  Nucl Instrum Methods Phys Res A       Date:  2012-11-21       Impact factor: 1.455

10.  Development and initial characterization of a high-resolution PET detector module with DOI.

Authors:  Mohan Li; Yuli Wang; Shiva Abbaszadeh
Journal:  Biomed Phys Eng Express       Date:  2020-10-14
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.