Literature DB >> 21969154

Impact of endoscopic and histological evaluations of two different types of mesh plug for a groin hernia model.

Yasuhiro Mandai1, Minoru Naito, Tatsuro Hayashi, Hiroaki Asano, Hideo Ino, Kazunori Tsukuda, Shinichiro Miyoshi.   

Abstract

PURPOSE: The biological responses to mesh in vivo have been evaluated in some papers, but the in vivo condition of mesh and plugs have not been sufficiently evaluated. This study evaluated the endoscopic observations and histological assessments of mesh plugs using swine models.
METHODS: An artificial abdominal hernia was established in the porcine abdomen, and repaired using three different sizes of two types of plug, Proloop (ATRIUM Medical Corporation, Hudson, NH, USA) or Perfix (BARD Medical Division, Covington, GA, USA). The in vivo conditions of each plug were periodically observed using a laparoscope. Moreover, a histological evaluation of the plugs was performed 3 months after implantation.
RESULTS: The laparoscopic observation revealed that inversion of the plugs occurred in 10 out of 18 cases repaired with Perfix, while no case repaired with Proloop inverted. The large and medium sizes of Perfix plugs were inclined by an average of more than 30°. In addition, the triangular shape of Perfix plugs was broken and the vertical/horizontal ratio was enlarged during the observation period, while Proloop plugs shrank both vertically and horizontally. The inflammatory cell count was significantly lower within the Proloop plugs than within Perfix plugs.
CONCLUSION: Proloop plugs are apparently superior because they are stable even 3 months after implantation.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21969154     DOI: 10.1007/s00595-010-4520-9

Source DB:  PubMed          Journal:  Surg Today        ISSN: 0941-1291            Impact factor:   2.549


  17 in total

1.  Functional impairment and complaints following incisional hernia repair with different polypropylene meshes.

Authors:  G Welty; U Klinge; B Klosterhalfen; R Kasperk; V Schumpelick
Journal:  Hernia       Date:  2001-09       Impact factor: 4.739

Review 2.  The lightweight and large porous mesh concept for hernia repair.

Authors:  Bernd Klosterhalfen; Karsten Junge; Uwe Klinge
Journal:  Expert Rev Med Devices       Date:  2005-01       Impact factor: 3.166

3.  A lightweight, partially absorbable mesh (Ultrapro) for endoscopic hernia repair: experimental biocompatibility results obtained with a porcine model.

Authors:  C Schug-Pass; C Tamme; F Sommerer; A Tannapfel; H Lippert; F Köckerling
Journal:  Surg Endosc       Date:  2007-10-26       Impact factor: 4.584

4.  [Pathology of traditional surgical nets for hernia repair after long-term implantation in humans].

Authors:  B Klosterhalfen; U Klinge; B Hermanns; V Schumpelick
Journal:  Chirurg       Date:  2000-01       Impact factor: 0.955

5.  Randomized clinical trial assessing impact of a lightweight or heavyweight mesh on chronic pain after inguinal hernia repair.

Authors:  P J O'Dwyer; A N Kingsnorth; R G Molloy; P K Small; B Lammers; G Horeyseck
Journal:  Br J Surg       Date:  2005-02       Impact factor: 6.939

6.  Totally extraperitoneal inguinal hernioplasty with titanium-coated lightweight polypropylene mesh: early results.

Authors:  C Tamme; N Garde; A Klingler; C Hampe; R Wunder; F Köckerling
Journal:  Surg Endosc       Date:  2005-05-26       Impact factor: 4.584

7.  Modified mesh for hernia repair that is adapted to the physiology of the abdominal wall.

Authors:  U Klinge; B Klosterhalfen; J Conze; W Limberg; B Obolenski; A P Ottinger; V Schumpelick
Journal:  Eur J Surg       Date:  1998-12

8.  European Hernia Society guidelines on the treatment of inguinal hernia in adult patients.

Authors:  M P Simons; T Aufenacker; M Bay-Nielsen; J L Bouillot; G Campanelli; J Conze; D de Lange; R Fortelny; T Heikkinen; A Kingsnorth; J Kukleta; S Morales-Conde; P Nordin; V Schumpelick; S Smedberg; M Smietanski; G Weber; M Miserez
Journal:  Hernia       Date:  2009-07-28       Impact factor: 4.739

9.  Mesh implants in hernia repair. Inflammatory cell response in a rat model.

Authors:  R Rosch; K Junge; A Schachtrupp; U Klinge; B Klosterhalfen; V Schumpelick
Journal:  Eur Surg Res       Date:  2003 May-Jun       Impact factor: 1.745

10.  Prospective histologic evaluation of intra-abdominal prosthetics four months after implantation in a rabbit model.

Authors:  Andrew G Harrell; Yuri W Novitsky; Joseph A Cristiano; Keith S Gersin; H James Norton; Kent W Kercher; B Todd Heniford
Journal:  Surg Endosc       Date:  2007-02-07       Impact factor: 3.453

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.