Literature DB >> 21959365

Thoracic respiratory motion estimation from MRI using a statistical model and a 2-D image navigator.

A P King1, C Buerger, C Tsoumpas, P K Marsden, T Schaeffter.   

Abstract

Respiratory motion models have potential application for estimating and correcting the effects of motion in a wide range of applications, for example in PET-MR imaging. Given that motion cycles caused by breathing are only approximately repeatable, an important quality of such models is their ability to capture and estimate the intra- and inter-cycle variability of the motion. In this paper we propose and describe a technique for free-form nonrigid respiratory motion correction in the thorax. Our model is based on a principal component analysis of the motion states encountered during different breathing patterns, and is formed from motion estimates made from dynamic 3-D MRI data. We apply our model using a data-driven technique based on a 2-D MRI image navigator. Unlike most previously reported work in the literature, our approach is able to capture both intra- and inter-cycle motion variability. In addition, the 2-D image navigator can be used to estimate how applicable the current motion model is, and hence report when more imaging data is required to update the model. We also use the motion model to decide on the best positioning for the image navigator. We validate our approach using MRI data acquired from 10 volunteers and demonstrate improvements of up to 40.5% over other reported motion modelling approaches, which corresponds to 61% of the overall respiratory motion present. Finally we demonstrate one potential application of our technique: MRI-based motion correction of real-time PET data for simultaneous PET-MRI acquisition.
Copyright © 2011 Elsevier B.V. All rights reserved.

Mesh:

Year:  2011        PMID: 21959365     DOI: 10.1016/j.media.2011.08.003

Source DB:  PubMed          Journal:  Med Image Anal        ISSN: 1361-8415            Impact factor:   8.545


  27 in total

1.  Accelerating volumetric cine MRI (VC-MRI) using undersampling for real-time 3D target localization/tracking in radiation therapy: a feasibility study.

Authors:  Wendy Harris; Fang-Fang Yin; Chunhao Wang; You Zhang; Jing Cai; Lei Ren
Journal:  Phys Med Biol       Date:  2017-12-14       Impact factor: 3.609

2.  Reduction of acquisition time in the intersection profile method for four-dimensional magnetic resonance imaging reconstruction of thoracoabdominal organs.

Authors:  Windra Swastika; Yoshitada Masuda; Takashi Ohnishi; Hideaki Haneishi
Journal:  J Med Imaging (Bellingham)       Date:  2015-06-03

Review 3.  Motion correction options in PET/MRI.

Authors:  Ciprian Catana
Journal:  Semin Nucl Med       Date:  2015-05       Impact factor: 4.446

Review 4.  Sequential whole-body PET/MR scanner: concept, clinical use, and optimisation after two years in the clinic. The manufacturer's perspective.

Authors:  Antonis Kalemis; Bénédicte M A Delattre; Susanne Heinzer
Journal:  MAGMA       Date:  2012-08-07       Impact factor: 2.310

5.  In vivo validation of spatio-temporal liver motion prediction from motion tracked on MR thermometry images.

Authors:  C Tanner; Y Zur; K French; G Samei; J Strehlow; G Sat; H McLeod; G Houston; S Kozerke; G Székely; A Melzer; T Preusser
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-04-12       Impact factor: 2.924

Review 6.  Advances in PET/MR instrumentation and image reconstruction.

Authors:  Jorge Cabello; Sibylle I Ziegler
Journal:  Br J Radiol       Date:  2016-07-22       Impact factor: 3.039

7.  Concurrent Respiratory Motion Correction of Abdominal PET and Dynamic Contrast-Enhanced-MRI Using a Compressed Sensing Approach.

Authors:  Niccolo Fuin; Onofrio A Catalano; Michele Scipioni; Lisanne P W Canjels; David Izquierdo-Garcia; Stefano Pedemonte; Ciprian Catana
Journal:  J Nucl Med       Date:  2018-01-25       Impact factor: 10.057

8.  Simulation of spatiotemporal CT data sets using a 4D MRI-based lung motion model.

Authors:  Mirko Marx; Jan Ehrhardt; René Werner; Heinz-Peter Schlemmer; Heinz Handels
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-12-10       Impact factor: 2.924

Review 9.  Positron emission tomography-magnetic resonance imaging: technical review.

Authors:  Raymond F Muzic; Frank P DiFilippo
Journal:  Semin Roentgenol       Date:  2014-10-18       Impact factor: 0.800

Review 10.  PET and MR imaging: the odd couple or a match made in heaven?

Authors:  Ciprian Catana; Alexander R Guimaraes; Bruce R Rosen
Journal:  J Nucl Med       Date:  2013-03-14       Impact factor: 10.057

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.