Accurate, reproducible measurement of blood pressure.

N R Campbell1, A Chockalingam, J G Fodor, D W McKay.   

Abstract

The diagnosis of mild hypertension and the treatment of hypertension require accurate measurement of blood pressure. Blood pressure readings are altered by various factors that influence the patient, the techniques used and the accuracy of the sphygmomanometer. The variability of readings can be reduced if informed patients prepare in advance by emptying their bladder and bowel, by avoiding over-the-counter vasoactive drugs the day of measurement and by avoiding exposure to cold, caffeine consumption, smoking and physical exertion within half an hour before measurement. The use of standardized techniques to measure blood pressure will help to avoid large systematic errors. Poor technique can account for differences in readings of more than 15 mm Hg and ultimately misdiagnosis. Most of the recommended procedures are simple and, when routinely incorporated into clinical practice, require little additional time. The equipment must be appropriate and in good condition. Physicians should have a suitable selection of cuff sizes readily available; the use of the correct cuff size is essential to minimize systematic errors in blood pressure measurement. Semiannual calibration of aneroid sphygmomanometers and annual inspection of mercury sphygmomanometers and blood pressure cuffs are recommended. We review the methods recommended for measuring blood pressure and discuss the factors known to produce large differences in blood pressure readings.

Entities:  

Mesh:

Year:  1990        PMID: 2192791      PMCID: PMC1452062     

Source DB:  PubMed          Journal:  CMAJ        ISSN: 0820-3946            Impact factor:   8.262


  17 in total

1.  EFFECT OF VERTICAL DISPLACEMENT OF THE ARM ON INDIRECT BLOOD-PRESSURE MEASUREMENT.

Authors:  P L MITCHELL; R W PARLIN; H BLACKBURN
Journal:  N Engl J Med       Date:  1964-07-09       Impact factor: 91.245

2.  Training and certification of blood pressure observers.

Authors:  J D Curb; D R Labarthe; S P Cooper; G R Cutter; C M Hawkins
Journal:  Hypertension       Date:  1983 Jul-Aug       Impact factor: 10.190

3.  Management of high blood pressure in general practice.

Authors:  M O'Hanrahan; M Laher; C O'Boyle; K O'Malley; E T O'Brien
Journal:  Ir Med J       Date:  1982-04

4.  Procedures and discrepancies of blood pressure measurements in two community health centers.

Authors:  L W Scherwitz; L A Evans; D J Hennrikus; C Vallbona
Journal:  Med Care       Date:  1982-07       Impact factor: 2.983

5.  Influence of arm position on measurement of blood pressure.

Authors:  J Webster; D Newnham; J C Petrie; H G Lovell
Journal:  Br Med J (Clin Res Ed)       Date:  1984-05-26

6.  The error in indirect blood pressure measurement with the incorrect size of cuff.

Authors:  L A Geddes; S J Whistler
Journal:  Am Heart J       Date:  1978-07       Impact factor: 4.749

7.  Errors in clinical measurement of blood pressure in obesity.

Authors:  G E King
Journal:  Clin Sci       Date:  1967-04       Impact factor: 6.124

8.  Report of the Canadian Hypertension Society's consensus conference on the management of mild hypertension.

Authors:  A G Logan
Journal:  Can Med Assoc J       Date:  1984-11-01       Impact factor: 8.262

9.  Osler's maneuver and pseudohypertension.

Authors:  F H Messerli; H O Ventura; C Amodeo
Journal:  N Engl J Med       Date:  1985-06-13       Impact factor: 91.245

10.  Sphygmomanometers in hospital and family practice: problems and recommendations.

Authors:  M J Burke; H M Towers; K O'Malley; D J Fitzgerald; E T O'Brien
Journal:  Br Med J (Clin Res Ed)       Date:  1982-08-14
View more
  9 in total

1.  Comparison of non-invasive blood pressure monitoring using modified arterial applanation tonometry with intra-arterial measurement.

Authors:  Jarkko Harju; Antti Vehkaoja; Pekka Kumpulainen; Stefano Campadello; Ville Lindroos; Arvi Yli-Hankala; Niku Oksala
Journal:  J Clin Monit Comput       Date:  2017-01-19       Impact factor: 2.502

2.  Continuous blood pressure measurement by using the pulse transit time: comparison to a cuff-based method.

Authors:  Heiko Gesche; Detlef Grosskurth; Gert Küchler; Andreas Patzak
Journal:  Eur J Appl Physiol       Date:  2011-05-10       Impact factor: 3.078

3.  Knowledge, attitude, behavior, and practice of interns toward errors in sphygmomanometer and blood pressure measurement.

Authors:  Ramachandran Meenakshisundaram; Shah Sweni; Govindaraj Dhanalakshmi; Raju Sridevi; Ponniah Thirumalaikolundusubramanian
Journal:  J Clin Hypertens (Greenwich)       Date:  2009-12       Impact factor: 3.738

4.  Measurement adherence in the blood pressure self-measurement room.

Authors:  Stefan Wagner; Niels Henrik Buus; Bente Jespersen; Peter Ahrendt; Olav W Bertelsen; Thomas S Toftegaard
Journal:  Telemed J E Health       Date:  2013-04-30       Impact factor: 3.536

5.  Challenges in blood pressure self-measurement.

Authors:  Stefan Wagner; Thomas Skjødeberg Toftegaard; Olav W Bertelsen
Journal:  Int J Telemed Appl       Date:  2012-03-18

6.  Impact of clinical input variable uncertainties on ten-year atherosclerotic cardiovascular disease risk using new pooled cohort equations.

Authors:  Himanshu Gupta; Chun G Schiros; Oleg F Sharifov; Apurva Jain; Thomas S Denney
Journal:  BMC Cardiovasc Disord       Date:  2016-08-31       Impact factor: 2.298

7.  Development and Validation of a Novel Cuff-Less Blood Pressure Monitoring Device.

Authors:  Naoki Watanabe; Yasuko K Bando; Taiji Kawachi; Hiroshi Yamakita; Kouki Futatsuyama; Yoshikazu Honda; Hisae Yasui; Kazuyuki Nishimura; Takahiro Kamihara; Takahiro Okumura; Hideki Ishii; Takahisa Kondo; Toyoaki Murohara
Journal:  JACC Basic Transl Sci       Date:  2017-12-25

8.  How does a short period of exercise effect toe pressures and toe-brachial indices? A cross-sectional exploratory study.

Authors:  Peta Ellen Tehan; Sean George Sadler; Sean Michael Lanting; Vivienne Helaine Chuter
Journal:  J Foot Ankle Res       Date:  2018-11-26       Impact factor: 2.303

9.  Diagnostic accuracy of resting systolic toe pressure for diagnosis of peripheral arterial disease in people with and without diabetes: a cross-sectional retrospective case-control study.

Authors:  Peta Ellen Tehan; Alex Louise Barwick; Mathew Sebastian; Vivienne Helaine Chuter
Journal:  J Foot Ankle Res       Date:  2017-12-19       Impact factor: 2.303

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.