Literature DB >> 21903869

Comparison of image quality and radiation dose between combined automatic tube current modulation and fixed tube current technique in CT of abdomen and pelvis.

Sanghee Lee1, Sang-Wook Yoon, Seung-Min Yoo, Young Geon Ji, Kyoung Ah Kim, Sang Heum Kim, Jong Tae Lee.   

Abstract

BACKGROUND: Tube current is an important determinant of radiation dose and image quality in X-ray-based examination. The combined automatic tube current modulation technique (ATCM) enables automatic adjustment of the tube current in various planes (x-y and z) based on the size and attenuation of the body area scanned.
PURPOSE: To compare image quality and radiation dose of the ATCM with those of a fixed tube current technique (FTC) in CT of the abdomen and pelvis performed with a 16-slice multidetector row CT.
MATERIAL AND METHODS: We reviewed 100 patients in whom initial and follow-up CT of the abdomen and pelvis were performed with FTC and ATCM. All acquisition parameters were identical in both techniques except for tube current. We recorded objective image noise in liver parenchyma, subjective image noise and diagnostic acceptability by using a five-point scale, radiation dose, and body mass index (BMI, kg/m(2)). Data were analyzed with parametric and non-parametric statistical tests.
RESULTS: There was no significant difference in image noise and diagnostic acceptability between two techniques. All subjects had acceptable subjective image noise in both techniques. The significant reduction in radiation dose (45.25% reduction) was noted with combined ATCM (P < 0.001). There was a significant linear statistical correlation between BMI and dose reduction (r = -0.78, P < 0.05).
CONCLUSION: The ATCM for CT of the abdomen and pelvis substantially reduced radiation dose while maintaining diagnostic image quality. Patients with lower BMI showed more reduction in radiation dose.

Entities:  

Mesh:

Year:  2011        PMID: 21903869     DOI: 10.1258/ar.2011.100295

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  11 in total

1.  Computed tomography of the chest with model-based iterative reconstruction using a radiation exposure similar to chest X-ray examination: preliminary observations.

Authors:  Angeliki Neroladaki; Diomidis Botsikas; Sana Boudabbous; Christoph D Becker; Xavier Montet
Journal:  Eur Radiol       Date:  2012-08-15       Impact factor: 5.315

2.  The associated factors for radiation dose variation in cardiac CT angiography.

Authors:  Ali B Alhailiy; Ernest U Ekpo; Peter L Kench; Elaine A Ryan; Patrick C Brennan; Mark McEntee
Journal:  Br J Radiol       Date:  2019-01-31       Impact factor: 3.039

3.  Impact of the scout view orientation on the radiation exposure and image quality in thoracic and abdominal CT.

Authors:  S Suntharalingam; A Wetter; N Guberina; J Theysohn; A Ringelstein; T Schlosser; M Forsting; K Nassenstein
Journal:  Eur Radiol       Date:  2016-03-04       Impact factor: 5.315

4.  How Much Is the Dose Varying between Follow-Up CT-Examinations Performed on the Same Scanner with the Same Imaging Protocol?

Authors:  Saravanabavaan Suntharalingam; Franz Ferdinand Stecker; Nika Guberina; Adrian Ringelstein; Thomas Schlosser; Jens Matthias Theysohn; Michael Forsting; Kai Nassenstein
Journal:  PLoS One       Date:  2016-04-06       Impact factor: 3.240

5.  Effect of tube current on computed tomography radiomic features.

Authors:  Dennis Mackin; Rachel Ger; Cristina Dodge; Xenia Fave; Pai-Chun Chi; Lifei Zhang; Jinzhong Yang; Steve Bache; Charles Dodge; A Kyle Jones; Laurence Court
Journal:  Sci Rep       Date:  2018-02-05       Impact factor: 4.379

6.  Efficiency and reproducibility in pulmonary nodule detection in simulated dose reduction lung CT images.

Authors:  Takeshi Kubo; Ayami Ohno Kishimoto; Kaori Togashi
Journal:  Eur J Radiol Open       Date:  2019-03-11

7.  Metal implants influence CT scan parameters leading to increased local radiation exposure: A proposal for correction techniques.

Authors:  Ok Kyu Song; Yong Eun Chung; Nieun Seo; Song-Ee Baek; Jin-Young Choi; Mi-Suk Park; Myeong-Jin Kim
Journal:  PLoS One       Date:  2019-08-23       Impact factor: 3.240

8.  The first joint ESGAR/ ESPR consensus statement on the technical performance of cross-sectional small bowel and colonic imaging.

Authors:  S A Taylor; F Avni; C G Cronin; C Hoeffel; S H Kim; A Laghi; M Napolitano; P Petit; J Rimola; D J Tolan; M R Torkzad; M Zappa; G Bhatnagar; C A J Puylaert; J Stoker
Journal:  Eur Radiol       Date:  2016-10-18       Impact factor: 5.315

9.  Evaluating the effect of increased pitch, iterative reconstruction and dual source CT on dose reduction and image quality.

Authors:  Joanna Gariani; Steve P Martin; Diomidis Botsikas; Christoph D Becker; Xavier Montet
Journal:  Br J Radiol       Date:  2018-06-14       Impact factor: 3.039

10.  Effects of the Use of Automatic Tube Current Modulation on Patient Dose and Image Quality in Computed Tomography

Authors:  Ayşegül Yurt; İsmail Özsoykal; Funda Obuz
Journal:  Mol Imaging Radionucl Ther       Date:  2019-09-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.