Literature DB >> 21860076

Low-dose CT reconstruction via edge-preserving total variation regularization.

Zhen Tian1, Xun Jia, Kehong Yuan, Tinsu Pan, Steve B Jiang.   

Abstract

High radiation dose in computed tomography (CT) scans increases the lifetime risk of cancer and has become a major clinical concern. Recently, iterative reconstruction algorithms with total variation (TV) regularization have been developed to reconstruct CT images from highly undersampled data acquired at low mAs levels in order to reduce the imaging dose. Nonetheless, the low-contrast structures tend to be smoothed out by the TV regularization, posing a great challenge for the TV method. To solve this problem, in this work we develop an iterative CT reconstruction algorithm with edge-preserving TV (EPTV) regularization to reconstruct CT images from highly undersampled data obtained at low mAs levels. The CT image is reconstructed by minimizing energy consisting of an EPTV norm and a data fidelity term posed by the x-ray projections. The EPTV term is proposed to preferentially perform smoothing only on the non-edge part of the image in order to better preserve the edges, which is realized by introducing a penalty weight to the original TV norm. During the reconstruction process, the pixels at the edges would be gradually identified and given low penalty weight. Our iterative algorithm is implemented on graphics processing unit to improve its speed. We test our reconstruction algorithm on a digital NURBS-based cardiac-troso phantom, a physical chest phantom and a Catphan phantom. Reconstruction results from a conventional filtered backprojection (FBP) algorithm and a TV regularization method without edge-preserving penalty are also presented for comparison purposes. The experimental results illustrate that both the TV-based algorithm and our EPTV algorithm outperform the conventional FBP algorithm in suppressing the streaking artifacts and image noise under a low-dose context. Our edge-preserving algorithm is superior to the TV-based algorithm in that it can preserve more information of low-contrast structures and therefore maintain acceptable spatial resolution.

Entities:  

Mesh:

Year:  2011        PMID: 21860076      PMCID: PMC4026331          DOI: 10.1088/0031-9155/56/18/011

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  21 in total

1.  GPU-based ultra-fast direct aperture optimization for online adaptive radiation therapy.

Authors:  Chunhua Men; Xun Jia; Steve B Jiang
Journal:  Phys Med Biol       Date:  2010-07-20       Impact factor: 3.609

2.  Real-time 3D computed tomographic reconstruction using commodity graphics hardware.

Authors:  Fang Xu; Klaus Mueller
Journal:  Phys Med Biol       Date:  2007-05-17       Impact factor: 3.609

3.  Estimated risks of radiation-induced fatal cancer from pediatric CT.

Authors:  D Brenner; C Elliston; E Hall; W Berdon
Journal:  AJR Am J Roentgenol       Date:  2001-02       Impact factor: 3.959

4.  Fast calculation of the exact radiological path for a three-dimensional CT array.

Authors:  R L Siddon
Journal:  Med Phys       Date:  1985 Mar-Apr       Impact factor: 4.071

5.  Radiation risk to children from computed tomography.

Authors:  Alan S Brody; Donald P Frush; Walter Huda; Robert L Brent
Journal:  Pediatrics       Date:  2007-09       Impact factor: 7.124

6.  Excess lifetime cancer mortality risk attributable to radiation exposure from computed tomography examinations in children.

Authors:  Gabriel Chodick; Cécile M Ronckers; Varda Shalev; Elaine Ron
Journal:  Isr Med Assoc J       Date:  2007-08       Impact factor: 0.892

7.  Radiation dose associated with common computed tomography examinations and the associated lifetime attributable risk of cancer.

Authors:  Rebecca Smith-Bindman; Jafi Lipson; Ralph Marcus; Kwang-Pyo Kim; Mahadevappa Mahesh; Robert Gould; Amy Berrington de González; Diana L Miglioretti
Journal:  Arch Intern Med       Date:  2009-12-14

8.  Implementation and evaluation of various demons deformable image registration algorithms on a GPU.

Authors:  Xuejun Gu; Hubert Pan; Yun Liang; Richard Castillo; Deshan Yang; Dongju Choi; Edward Castillo; Amitava Majumdar; Thomas Guerrero; Steve B Jiang
Journal:  Phys Med Biol       Date:  2010-01-07       Impact factor: 3.609

9.  Projected cancer risks from computed tomographic scans performed in the United States in 2007.

Authors:  Amy Berrington de González; Mahadevappa Mahesh; Kwang-Pyo Kim; Mythreyi Bhargavan; Rebecca Lewis; Fred Mettler; Charles Land
Journal:  Arch Intern Med       Date:  2009-12-14

10.  GPU-based ultra-fast dose calculation using a finite size pencil beam model.

Authors:  Xuejun Gu; Dongju Choi; Chunhua Men; Hubert Pan; Amitava Majumdar; Steve B Jiang
Journal:  Phys Med Biol       Date:  2009-10-01       Impact factor: 3.609

View more
  66 in total

1.  Statistical iterative reconstruction to improve image quality for digital breast tomosynthesis.

Authors:  Shiyu Xu; Jianping Lu; Otto Zhou; Ying Chen
Journal:  Med Phys       Date:  2015-09       Impact factor: 4.071

2.  Progressive cone beam CT dose control in image-guided radiation therapy.

Authors:  Hao Yan; Xin Zhen; Laura Cerviño; Steve B Jiang; Xun Jia
Journal:  Med Phys       Date:  2013-06       Impact factor: 4.071

3.  MR image reconstruction based on framelets and nonlocal total variation using split Bregman method.

Authors:  Varun P Gopi; P Palanisamy; Khan A Wahid; Paul Babyn
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-09-08       Impact factor: 2.924

4.  Towards the clinical implementation of iterative low-dose cone-beam CT reconstruction in image-guided radiation therapy: cone/ring artifact correction and multiple GPU implementation.

Authors:  Hao Yan; Xiaoyu Wang; Feng Shi; Ti Bai; Michael Folkerts; Laura Cervino; Steve B Jiang; Xun Jia
Journal:  Med Phys       Date:  2014-11       Impact factor: 4.071

5.  Statistical image reconstruction for low-dose CT using nonlocal means-based regularization. Part II: An adaptive approach.

Authors:  Hao Zhang; Jianhua Ma; Jing Wang; Yan Liu; Hao Han; Hongbing Lu; William Moore; Zhengrong Liang
Journal:  Comput Med Imaging Graph       Date:  2015-03-06       Impact factor: 4.790

6.  Structure-adaptive CBCT reconstruction using weighted total variation and Hessian penalties.

Authors:  Qi Shi; Nanbo Sun; Tao Sun; Jing Wang; Shan Tan
Journal:  Biomed Opt Express       Date:  2016-08-09       Impact factor: 3.732

7.  Subspace-based resolution-enhancing image reconstruction method for few-view differential phase-contrast tomography.

Authors:  Huifeng Guan; Charlotte Klara Hagen; Alessandro Olivo; Mark A Anastasio
Journal:  J Med Imaging (Bellingham)       Date:  2018-06-28

8.  Improving thoracic four-dimensional cone-beam CT reconstruction with anatomical-adaptive image regularization (AAIR).

Authors:  Chun-Chien Shieh; John Kipritidis; Ricky T O'Brien; Benjamin J Cooper; Zdenka Kuncic; Paul J Keall
Journal:  Phys Med Biol       Date:  2015-01-07       Impact factor: 3.609

9.  Statistical CT reconstruction using region-aware texture preserving regularization learning from prior normal-dose CT image.

Authors:  Xiao Jia; Yuting Liao; Dong Zeng; Hao Zhang; Yuanke Zhang; Ji He; Zhaoying Bian; Yongbo Wang; Xi Tao; Zhengrong Liang; Jing Huang; Jianhua Ma
Journal:  Phys Med Biol       Date:  2018-11-20       Impact factor: 3.609

10.  Adaptive-weighted total variation minimization for sparse data toward low-dose x-ray computed tomography image reconstruction.

Authors:  Yan Liu; Jianhua Ma; Yi Fan; Zhengrong Liang
Journal:  Phys Med Biol       Date:  2012-11-15       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.