Literature DB >> 21858863

Parallel traveling-wave MRI: a feasibility study.

Yong Pang1, Daniel B Vigneron, Xiaoliang Zhang.   

Abstract

Traveling-wave magnetic resonance imaging utilizes far fields of a single-piece patch antenna in the magnet bore to generate radio frequency fields for imaging large-size samples, such as the human body. In this work, the feasibility of applying the "traveling-wave" technique to parallel imaging is studied using microstrip patch antenna arrays with both the numerical analysis and experimental tests. A specific patch array model is built and each array element is a microstrip patch antenna. Bench tests show that decoupling between two adjacent elements is better than -26-dB while matching of each element reaches -36-dB, demonstrating excellent isolation performance and impedance match capability. The sensitivity patterns are simulated and g-factors are calculated for both unloaded and loaded cases. The results on B 1- sensitivity patterns and g-factors demonstrate the feasibility of the traveling-wave parallel imaging. Simulations also suggest that different array configuration such as patch shape, position and orientation leads to different sensitivity patterns and g-factor maps, which provides a way to manipulate B(1) fields and improve the parallel imaging performance. The proposed method is also validated by using 7T MR imaging experiments.
Copyright © 2011 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 21858863      PMCID: PMC3223536          DOI: 10.1002/mrm.23073

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  28 in total

1.  High-resolution intracranial and cervical MRA at 3.0T: technical considerations and initial experience.

Authors:  M A Bernstein; J Huston; C Lin; G F Gibbs; J P Felmlee
Journal:  Magn Reson Med       Date:  2001-11       Impact factor: 4.668

2.  Microstrip RF surface coil design for extremely high-field MRI and spectroscopy.

Authors:  X Zhang; K Ugurbil; W Chen
Journal:  Magn Reson Med       Date:  2001-09       Impact factor: 4.668

3.  A microstrip transmission line volume coil for human head MR imaging at 4T.

Authors:  Xiaoliang Zhang; Kamil Ugurbil; Wei Chen
Journal:  J Magn Reson       Date:  2003-04       Impact factor: 2.229

4.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

5.  Polarization of the RF field in a human head at high field: a study with a quadrature surface coil at 7.0 T.

Authors:  Jinghua Wang; Qing X Yang; Xiaoliang Zhang; Christopher M Collins; Michael B Smith; Xiao-Hong Zhu; Gregor Adriany; Kamil Ugurbil; Wei Chen
Journal:  Magn Reson Med       Date:  2002-08       Impact factor: 4.668

6.  Efficient high-frequency body coil for high-field MRI.

Authors:  J T Vaughan; G Adriany; C J Snyder; J Tian; T Thiel; L Bolinger; H Liu; L DelaBarre; K Ugurbil
Journal:  Magn Reson Med       Date:  2004-10       Impact factor: 4.668

7.  Parallel imaging reconstruction using automatic regularization.

Authors:  Fa-Hsuan Lin; Kenneth K Kwong; John W Belliveau; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2004-03       Impact factor: 4.668

8.  The NMR phased array.

Authors:  P B Roemer; W A Edelstein; C E Hayes; S P Souza; O M Mueller
Journal:  Magn Reson Med       Date:  1990-11       Impact factor: 4.668

9.  Ultimate intrinsic signal-to-noise ratio in MRI.

Authors:  O Ocali; E Atalar
Journal:  Magn Reson Med       Date:  1998-03       Impact factor: 4.668

10.  Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays.

Authors:  D K Sodickson; W J Manning
Journal:  Magn Reson Med       Date:  1997-10       Impact factor: 4.668

View more
  10 in total

1.  Image homogenization using pre-emphasis method for high field MRI.

Authors:  Ye Li; Chunsheng Wang; Baiying Yu; Daniel Vigneron; Wei Chen; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2013-08

2.  Design and Test of Magnetic Wall Decoupling for Dipole Transmit/Receive Array for MR Imaging at the Ultrahigh Field of 7T.

Authors:  Xinqiang Yan; Xiaoliang Zhang; Long Wei; Rong Xue
Journal:  Appl Magn Reson       Date:  2014-11-27       Impact factor: 0.831

3.  Design of catheter radio frequency coils using coaxial transmission line resonators for interventional neurovascular MR imaging.

Authors:  Xiaoliang Zhang; Alastair Martin; Caroline Jordan; Prasheel Lillaney; Aaron Losey; Yong Pang; Jeffrey Hu; Mark Wilson; Daniel Cooke; Steven W Hetts
Journal:  Quant Imaging Med Surg       Date:  2017-04

4.  Sensitivity enhancement of traveling wave MRI using free local resonators: an experimental demonstration.

Authors:  Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2017-04

5.  Improved traveling-wave efficiency in 7T human MRI using passive local loop and dipole arrays.

Authors:  Xinqiang Yan; Xiaoliang Zhang; John C Gore; William A Grissom
Journal:  Magn Reson Imaging       Date:  2017-02-09       Impact factor: 2.546

6.  Hepatic fat assessment using advanced Magnetic Resonance Imaging.

Authors:  Yong Pang; Baiying Yu; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2012-09

7.  Magnetic wall decoupling method for monopole coil array in ultrahigh field MRI: a feasibility test.

Authors:  Xinqiang Yan; Xiaoliang Zhang; Long Wei; Rong Xue
Journal:  Quant Imaging Med Surg       Date:  2014-04

Review 8.  Magnetic resonance imaging for lung cancer screen.

Authors:  Yi-Xiang J Wang; Gladys G Lo; Jing Yuan; Peder E Z Larson; Xiaoliang Zhang
Journal:  J Thorac Dis       Date:  2014-09       Impact factor: 2.895

9.  Multi-reception strategy with improved SNR for multichannel MR imaging.

Authors:  Bing Wu; Ye Li; Chunsheng Wang; Daniel B Vigneron; Xiaoliang Zhang
Journal:  PLoS One       Date:  2012-08-03       Impact factor: 3.240

10.  Planar quadrature RF transceiver design using common-mode differential-mode (CMDM) transmission line method for 7T MR imaging.

Authors:  Ye Li; Baiying Yu; Yong Pang; Daniel B Vigneron; Xiaoliang Zhang
Journal:  PLoS One       Date:  2013-11-12       Impact factor: 3.240

  10 in total