Literature DB >> 23749464

Fast and robust extraction of surrogate respiratory signal from intra-operative liver ultrasound images.

Jiaze Wu1, Cheng Li, Su Huang, Feng Liu, Bien Soo Tan, London Lucien Ooi, Haoyong Yu, Jimin Liu.   

Abstract

PURPOSE: In model-based respiratory motion estimation for the liver or other abdominal organs, the surrogate respiratory signal is usually obtained by using special tracking devices from skin or diaphragm, and subsequently applied to parameterize a 4D motion model for prediction or compensation. However, due to the intrinsic limits and economical costs of these tracking devices, the identification of the respiratory signal directly from intra-operative ultrasound images is a more attractive alternative.
METHODS: We propose a fast and robust method to extract the respiratory motion of the liver from an intra-operative 2D ultrasound image sequence. Our method employs a preprocess to remove speckle-like noises in the ultrasound images and utilizes the normalized cross-correlation to measure the image similarity fast. More importantly, we present a novel adaptive search strategy, which makes full use of the inter-frame dependency of the image sequence. This search strategy narrows the search range of the optimal matching, thus greatly reduces the search time, and makes the matching process more robust and accurate.
RESULTS: The experimental results on four volunteers demonstrate that our method is able to extract the respiratory signal from an image sequence of 256 image frames in 5 s. The quantitative evaluation using the correlation coefficient reveals that the respiratory motion, extracted near the liver boundaries and vessels, is highly consistent with the reference motion tracked by an EM device.
CONCLUSIONS: Our method can use 2D ultrasound to track natural landmarks from the liver as surrogate respiratory signal and hence provide a feasible solution to replace special tracking devices.

Mesh:

Year:  2013        PMID: 23749464     DOI: 10.1007/s11548-013-0902-y

Source DB:  PubMed          Journal:  Int J Comput Assist Radiol Surg        ISSN: 1861-6410            Impact factor:   2.924


  9 in total

Review 1.  Robotic prostate biopsy and its relevance to focal therapy of prostate cancer.

Authors:  Henry Ho; John S P Yuen; Christopher W S Cheng
Journal:  Nat Rev Urol       Date:  2011-09-20       Impact factor: 14.432

Review 2.  Mutual-information-based registration of medical images: a survey.

Authors:  Josien P W Pluim; J B Antoine Maintz; Max A Viergever
Journal:  IEEE Trans Med Imaging       Date:  2003-08       Impact factor: 10.048

3.  Modeling liver motion and deformation during the respiratory cycle using intensity-based nonrigid registration of gated MR images.

Authors:  Torsten Rohlfing; Calvin R Maurer; Walter G O'Dell; Jianhui Zhong
Journal:  Med Phys       Date:  2004-03       Impact factor: 4.071

4.  3D organ motion prediction for MR-guided high intensity focused ultrasound.

Authors:  Patrik Arnold; Frank Preiswerk; Beat Fasel; Rares Salomir; Klaus Scheffler; Philippe C Cattin
Journal:  Med Image Comput Comput Assist Interv       Date:  2011

5.  Effects of respiratory liver motion on heating for gated and model-based motion-compensated high-intensity focused ultrasound ablation.

Authors:  Erik-Jan Rijkhorst; Ian Rivens; Gail ter Haar; David Hawkes; Dean Barratt
Journal:  Med Image Comput Comput Assist Interv       Date:  2011

6.  Automatic tracking of an organ section with an ultrasound probe: compensation of respiratory motion.

Authors:  Caroline Nadeau; Alexandre Krupa; Jacques Gangloff
Journal:  Med Image Comput Comput Assist Interv       Date:  2011

7.  Correlating chest surface motion to motion of the liver using epsilon-SVR--a porcine study.

Authors:  Floris Ernst; Volker Martens; Stefan Schlichting; Armin Besirević; Markus Kleemann; Christoph Koch; Dirk Petersen; Achim Schweikard
Journal:  Med Image Comput Comput Assist Interv       Date:  2009

Review 8.  Respiratory motion models: a review.

Authors:  J R McClelland; D J Hawkes; T Schaeffter; A P King
Journal:  Med Image Anal       Date:  2012-10-08       Impact factor: 8.545

9.  Correlation between external and internal respiratory motion: a validation study.

Authors:  Floris Ernst; Ralf Bruder; Alexander Schlaefer; Achim Schweikard
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-08-19       Impact factor: 2.924