Literature DB >> 2184232

A finite element survey of eleven endosseous implants.

M R Rieger1, W K Adams, G L Kinzel.   

Abstract

Eleven different post-type endosseous implants were biomechanically analyzed by use of the finite element method to compile a list of features that could be used to design an optimal post-type endosseous implant. Stress magnitudes and contours within each implant and within the surrounding bone were calculated. Implant features causing high stresses and low stresses, possibly contributing to pathologic bone resorption and bone atrophy were noted. Although this preliminary survey was not complete, tentative suggestions in implant design for improved implant performance were made.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2184232     DOI: 10.1016/0022-3913(90)90238-8

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  7 in total

1.  The effect of thread design on stress distribution in a solid screw implant: a 3D finite element analysis.

Authors:  Oğuz Eraslan; Ozgür Inan
Journal:  Clin Oral Investig       Date:  2009-06-20       Impact factor: 3.573

2.  Photoelastic stress analysis in prosthetic implants of different diameters: mini, narrow, standard or wide.

Authors:  Marcelo Coelho Goiato; Alves Aldiéris Pesqueira; Daniela Micheline Dos Santos; Marcela Filié Haddad; Amália Moreno
Journal:  J Clin Diagn Res       Date:  2014-09-20

3.  Influence of Implant Surface Topography and Loading Condition on Stress Distribution in Bone Around Implants: A Comparative 3D FEA.

Authors:  Ravindra C Savadi; Jatin Agarwal; Rolly Shrivastava Agarwal; V Rangarajan
Journal:  J Indian Prosthodont Soc       Date:  2011-10-19

4.  Stress distribution on a three-unit implant-supported zirconia framework. A 3D finite element analysis and fatigue test.

Authors:  G Sannino; A Pozzi; R Schiavetti; A Barlattani
Journal:  Oral Implantol (Rome)       Date:  2012-07-17

5.  3D finite element non linear analysis on the stress state at bone-implant interface in dental osteointegrated implants.

Authors:  G Sannino; G Marra; L Feo; A Barlattani
Journal:  Oral Implantol (Rome)       Date:  2011-01-13

6.  Finite element analysis on stress distribution of maxillary implant-retained overdentures depending on the Bar attachment design and palatal coverage.

Authors:  Min-Jeong Kim; Sung-Ok Hong
Journal:  J Adv Prosthodont       Date:  2016-04-21       Impact factor: 1.904

7.  Relationships of Stresses on Alveolar Bone and Abutment of Dental Implant from Various Bite Forces by Three-Dimensional Finite Element Analysis.

Authors:  Xiaoning Kang; Yiming Li; Yixi Wang; Yao Zhang; Dongsheng Yu; Yun Peng
Journal:  Biomed Res Int       Date:  2020-02-19       Impact factor: 3.411

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.