Literature DB >> 12058265

The accuracy and reliability of radiographic methods for the assessment of marginal bone level around oral implants.

E De Smet1, R Jacobs, F Gijbels, I Naert.   

Abstract

OBJECTIVES: To determine the accuracy and reliability of radiographic methods for assessment of the marginal bone level around oral implants in human cadavers.
METHODS: In three human cadavers two implants were placed according to the Instruction Manual for the Brånemark System. One implant was installed in the canine and one in the premolar region of the left mandible. For each implant, conventional and digital intra-oral paralleling radiography were performed. Digital images were printed with a Kodak 1200 Distributed Medical Imaging printer on blue transparent film, glossy and plain paper. Furthermore, digital scanographic, panoramic and tomographic images were taken with the Cranex Tome multimodal X-ray unit and printed on Agfa Drystar TM 1 B transparent films. All images were evaluated by five dental specialists. Data were statistically compared with real measurements of the marginal bone level on the human cadavers, performed by the same group of observers. Intra- and inter-observer variability were determined.
RESULTS: Digital intra-oral images on glossy paper showed the smallest absolute difference between real and measured bone level, followed by digital intra-oral images on film and on plain paper, conventional intra-oral images on analogue film, panoramic, scanographic and tomographic images on film. The difference between real and radiographic measurements was not statistically significant (P>0.05) for all radiographic techniques. Intra- and inter-observer reproducibility was high for all techniques.
CONCLUSIONS: The selected imaging techniques showed an acceptable accuracy for peri-implant bone level measurements with an overall error of less than 0.5 mm. Intra-oral images showed the smallest absolute differences.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12058265     DOI: 10.1038/sj/dmfr/4600694

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  12 in total

1.  Mandibular Third Molar Extraction Wound Healing With and Without Platelet Rich Plasma: A Comparative Prospective Study.

Authors:  Shubha Ranjan Dutta; Purnima Singh; Deepak Passi; Pradeep Patter
Journal:  J Maxillofac Oral Surg       Date:  2015-01-23

2.  A paralleling technique modification to determine the bone crest level around dental implants.

Authors:  Noelia Fernández-Formoso; B Rilo; M J Mora; I Martínez-Silva; U Santana
Journal:  Dentomaxillofac Radiol       Date:  2011-09       Impact factor: 2.419

3.  Annual bone loss and success rates of dental implants based on radiographic measurements.

Authors:  W Geraets; L Zhang; Y Liu; D Wismeijer
Journal:  Dentomaxillofac Radiol       Date:  2014-07-17       Impact factor: 2.419

4.  Influence of platform switching on bone-level alterations: a three-year randomized clinical trial.

Authors:  N Enkling; P Jöhren; J Katsoulis; S Bayer; P-M Jervøe-Storm; R Mericske-Stern; S Jepsen
Journal:  J Dent Res       Date:  2013-10-24       Impact factor: 6.116

5.  Peri-implant bone changes in immediate and non-immediate root-analog stepped implants-a matched comparative prospective study up to 10 years.

Authors:  German Gomez-Roman; Steffen Launer
Journal:  Int J Implant Dent       Date:  2016-05-23

6.  A 3-Year Prospective Study on a Porcine-Derived Acellular Collagen Matrix to Re-Establish Convexity at the Buccal Aspect of Single Implants in the Molar Area: A Volumetric Analysis.

Authors:  Célien Eeckhout; Eline Bouckaert; Dagmar Verleyen; Thomas De Bruyckere; Jan Cosyn
Journal:  J Clin Med       Date:  2020-05-22       Impact factor: 4.241

7.  Peri-Implant Bone Resorption during Healing Abutment Placement: The Effect of a 0.20% Chlorhexidine Gel vs. Placebo-A Randomized Double Blind Controlled Human Study.

Authors:  Bruna Sinjari; Gianmaria D'Addazio; Ilaria De Tullio; Tonino Traini; Sergio Caputi
Journal:  Biomed Res Int       Date:  2018-10-16       Impact factor: 3.411

8.  Diagnostic Accuracy of Three Cone Beam Computed Tomography Systems and Periapical Radiography for Detection of Fenestration Around Dental Implants.

Authors:  Amir Eskandarloo; Samira Saati; Mahbubeh Purabdolahi Ardakani; Mohamadreza Jamalpour; Naser Mohammad Gholi Mezerji; Vahid Akheshteh
Journal:  Contemp Clin Dent       Date:  2018 Jul-Sep

9.  Effect of platform switching on crestal bone levels around implants in the posterior mandible: 3 years results from a multicentre randomized clinical trial.

Authors:  Salomão Rocha; Wilfried Wagner; Jörg Wiltfang; Pedro Nicolau; Maximilian Moergel; Ana Messias; Eleonore Behrens; Fernando Guerra
Journal:  J Clin Periodontol       Date:  2016-03-30       Impact factor: 8.728

10.  A 4 Year Human, Randomized, Radiographic Study of Scalloped versus Non-Scalloped Cemented Implants.

Authors:  Bruna Sinjari; Gianmaria D'Addazio; Manlio Santilli; Barbara D'Avanzo; Imena Rexhepi; Antonio Scarano; Tonino Traini; Maurizio Piattelli; Sergio Caputi
Journal:  Materials (Basel)       Date:  2020-05-10       Impact factor: 3.623

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.