M A Hassaballa1, T A Macky. 1. Department of Ophthalmology, Kasr El Aini Hospital, Cairo University, Cairo, Egypt.
Abstract
PURPOSE: To evaluate the safety and visual outcomes of two phakic intraocular lenses (IOLs) for correction of high myopia: Artisan and Visian ICL (ICL). PATIENTS AND METHODS: In this retrospective study, a phakic IOL was implanted in 68 highly myopic eyes of 34 patients; 42 eyes received an Artisan IOL, and 26 eyes received ICL IOL. RESULTS: All patients completed a 1-year follow-up. The mean preoperative spherical equivalent (SEQ) was -12.89 ± 3.78, and -12.44 ± 4.15 diopters (D) for Artisan and ICL (P=0.078), respectively. The mean postoperative (1-year) uncorrected distance visual acuity was 0.39 ± 0.13 and 0.41 ± 0.15 logMAR for Artisan and ICL, respectively (P=0.268). The mean postoperative (1-year) corrected distance visual acuity was 0.36 ± 0.12 and 0.31 ± 0.12 logMAR for Artisan and ICL, respectively (P=0.128). The mean postoperative SEQ was -0.86 ± 0.5 and -0.63 ± 0.38 D for Artisan and ICL, respectively (P=0.67). Intraocular pressure change at 1 year was 0.64 ± 2.7 and 1.88 ± 0.6 mm Hg for Artisan and ICL, respectively (P=0.77). CONCLUSION: Artisan and ICL showed equal and comparable safety, predictability, and efficacy.
PURPOSE: To evaluate the safety and visual outcomes of two phakic intraocular lenses (IOLs) for correction of high myopia: Artisan and Visian ICL (ICL). PATIENTS AND METHODS: In this retrospective study, a phakic IOL was implanted in 68 highly myopic eyes of 34 patients; 42 eyes received an Artisan IOL, and 26 eyes received ICL IOL. RESULTS: All patients completed a 1-year follow-up. The mean preoperative spherical equivalent (SEQ) was -12.89 ± 3.78, and -12.44 ± 4.15 diopters (D) for Artisan and ICL (P=0.078), respectively. The mean postoperative (1-year) uncorrected distance visual acuity was 0.39 ± 0.13 and 0.41 ± 0.15 logMAR for Artisan and ICL, respectively (P=0.268). The mean postoperative (1-year) corrected distance visual acuity was 0.36 ± 0.12 and 0.31 ± 0.12 logMAR for Artisan and ICL, respectively (P=0.128). The mean postoperative SEQ was -0.86 ± 0.5 and -0.63 ± 0.38 D for Artisan and ICL, respectively (P=0.67). Intraocular pressure change at 1 year was 0.64 ± 2.7 and 1.88 ± 0.6 mm Hg for Artisan and ICL, respectively (P=0.77). CONCLUSION: Artisan and ICL showed equal and comparable safety, predictability, and efficacy.
Authors: I Jiménez-Alfaro; J M Benítez del Castillo; J García-Feijoó; J G Gil de Bernabé; J M Serrano de La Iglesia Journal: Ophthalmology Date: 2001-01 Impact factor: 12.079
Authors: César A Sánchez-Galeana; David Zadok; Miguel Montes; Marco A Cortés; Arturo S Chayet Journal: Am J Ophthalmol Date: 2002-07 Impact factor: 5.258
Authors: Gary A Varley; David Huang; Christopher J Rapuano; Steven Schallhorn; Brian S Boxer Wachler; Alan Sugar Journal: Ophthalmology Date: 2004-08 Impact factor: 12.079
Authors: Virgilio Galvis; John F Villamil; María Fernanda Acuña; Paul A Camacho; Jesús Merayo-Lloves; Alejandro Tello; Sandra Lizeth Zambrano; Juan José Rey; Juan Vicente Espinoza; Angélica María Prada Journal: Graefes Arch Clin Exp Ophthalmol Date: 2019-10-28 Impact factor: 3.117
Authors: Rafic Antonios; Ali Dirani; Ali Fadlallah; Elias Chelala; Adib Hamade; Carole Cherfane; Elias Jarade Journal: J Ophthalmol Date: 2015-03-19 Impact factor: 1.909
Authors: Soraya M R Jonker; Tos T J M Berendschot; Isabelle E Y Saelens; Noël J C Bauer; Rudy M M A Nuijts Journal: Indian J Ophthalmol Date: 2020-12 Impact factor: 1.848