Literature DB >> 17598571

Matched population comparison of the Visian Implantable Collamer Lens and standard LASIK for myopia of -3.00 to -7.88 diopters.

Donald R Sanders1.   

Abstract

PURPOSE: To compare matched populations of LASIK and Visian Implantable Collamer Lens (ICL) cases in the correction of myopia between -3.00 and -7.88 diopters (D).
METHODS: One hundred sixty-four LASIK eyes with prospective data collected from a single center and 164 ICL eyes from the multicenter US ICL Clinical Trial were compared in this observational non-randomized study. The LASIK and ICL groups were well matched for age, gender, and mean level of preoperative spherical equivalent refraction.
RESULTS: At 6 months, best spectacle-corrected visual acuity (BSCVA) > or = 20/20 was 85% with LASIK and 95% with ICL (P = .003) compared to preoperative values of 93% and 88%, respectively (P = .292). Loss of > or = 2 lines of BSCVA was significantly lower with the ICL at 1 week (0.6% vs 10%, P < .001) and 1 month (7% vs 0%, P = .001) with comparable outcomes at 6 months (0% vs 1%). At 6 months postoperatively, uncorrected visual acuity (UCVA) > or = 20/15 (11% vs 25%, P = .001) and > or = 20/20 (49% vs 63%, P = .001) was better in the ICL cases. Predictability within 0.50 D at 6 months for ICL cases was 85% (67% LASIK, P < .001); 97% of ICL cases were within 1.00 D (88% LASIK, P = .002). Refractive stability (+/- 0.50 D) between 1 and 6 months was 93% with ICL compared to only 82% with LASIK (P = .006).
CONCLUSIONS: The ICL performed better than LASIK in almost all measures of safety, efficacy, predictability, and stability in this matched population comparison, supporting the ICL as an effective alternative to existing refractive laser surgical treatments for the range of myopia studied.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17598571     DOI: 10.3928/1081-597X-20070601-02

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  20 in total

1.  Phakic intraocular lenses outcomes and complications: Artisan vs Visian ICL.

Authors:  M A Hassaballa; T A Macky
Journal:  Eye (Lond)       Date:  2011-08-05       Impact factor: 3.775

2.  Optical quality of the Visian Implantable Collamer Lens for different refractive powers.

Authors:  Cari Pérez-Vives; Alberto Domínguez-Vicent; Teresa Ferrer-Blasco; Álvaro M Pons; Robert Montés-Micó
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-11-11       Impact factor: 3.117

Review 3.  [Phakic intraocular lenses].

Authors:  T Kohnen; M Shajari
Journal:  Ophthalmologe       Date:  2016-06       Impact factor: 1.059

4.  Reasons for not performing keratorefractive surgery in patients seeking refractive surgery in a hospital-based cohort in "yemen".

Authors:  Mahfouth A Bamashmus; Mahmoud F Saleh; Mohamed A Awadalla
Journal:  Middle East Afr J Ophthalmol       Date:  2010-10

5.  Phakic intraocular lenses for the treatment of refractive errors: an evidence-based analysis.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2009-10-01

6.  Visian implantable contact lens versus AcrySof Cachet phakic intraocular lenses: comparison of aberrmetric profiles.

Authors:  Mohamed Hm Hosny; Ahmad Mm Shalaby
Journal:  Clin Ophthalmol       Date:  2013-07-22

7.  Effect of Myopic Defocus on Visual Acuity after Phakic Intraocular Lens Implantation and Wavefront-guided Laser in Situ Keratomileusis.

Authors:  Kazutaka Kamiya; Kimiya Shimizu; Akihito Igarashi; Takushi Kawamorita
Journal:  Sci Rep       Date:  2015-05-21       Impact factor: 4.379

8.  Implantable collamer lens versus iris-fixed phakic intraocular lens implantation to correct myopia: a meta-analysis.

Authors:  Guan-Lu Liang; Jing Wu; Jun-Ting Shi; Jian Liu; Feng-Ying He; Wen Xu
Journal:  PLoS One       Date:  2014-08-12       Impact factor: 3.240

9.  Comparison of three phakic intraocular lenses for correction of myopia.

Authors:  Farid Karimian; Alireza Baradaran-Rafii; Seyed Javad Hashemian; Ali Hashemloo; Mohammad Ebrahim Jafari; Mehdi Yaseri; Elham Ghahari; Shadi Akbarian
Journal:  J Ophthalmic Vis Res       Date:  2014 Oct-Dec

10.  Stability of axis and patient satisfaction after toric implantable collamer lens implantation for myopic astigmatism.

Authors:  Tai-Xiang Liu; Xin Luo
Journal:  Pak J Med Sci       Date:  2013-11       Impact factor: 1.088

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.