Literature DB >> 18041238

Randomized prospective comparison of visian toric implantable collamer lens and conventional photorefractive keratectomy for moderate to high myopic astigmatism.

Steven Schallhorn1, David Tanzer, Donald R Sanders, Monica L Sanders.   

Abstract

PURPOSE: To compare the Visian Toric Implantable Collamer Lens (TICL), a toric phakic intraocular lens (IOL), and photorefractive keratectomy (PRK) in the correction of moderate to high myopic astigmatism.
METHODS: This prospective, randomized study consisted of 43 eyes implanted with the TICL (20 bilateral cases) and 45 eyes receiving PRK with mitomycin C (22 bilateral cases) with moderate to high myopia (-6.00 to -20.00 diopters [D] sphere) measured at the spectacle plane and 1.00 to 4.00 D of astigmatism. All patient treatment and follow-up occurred at the Naval Medical Center San Diego. Study follow-up was 1 day, 1 week, 1, 3, 6, and 12 months postoperative.
RESULTS: Mean best spectacle-corrected visual acuity (BSCVA), change in BSCVA, proportion of cases with improvement of 1 or more lines of BSCVA, proportion of cases with BSCVA and uncorrected visual acuity (UCVA) 20/12.5 or better, proportion of cases with BSCVA and UCVA 20/16 or better (6 months, 88% vs 54%, P=.002), and predictability +/-1.00 D (6 months, 100% vs 67%, P<.001) were all significantly better in the TICL group than the PRK group at all time periods studied postoperatively. Similarly, contrast sensitivity, tested at both the 5% photopic level and the 25% mesopic level, was significantly better at all postoperative time points in the TICL group. Mean spherical equivalent refraction was closer to emmetropia (0.28+/-0.41 vs 0.76+/-0.86, P=.005), and predictability +/-0.50 D and stability of manifest refraction (+/-0.50 D and +/-1.00 D) were significantly better in the TICL group at all postoperative visits through 6 months. Mean astigmatism correction at 6 months was not significantly different between the two groups (0.52+/-0.33 vs 0.46+/-0.35, P=.450).
CONCLUSIONS: The TICL performed better than PRK in all measures of safety (BSCVA), efficacy (UCVA), predictability, and stability in this comparison, supporting the TICL as a viable alternative to existing refractive surgical treatments.

Entities:  

Mesh:

Year:  2007        PMID: 18041238     DOI: 10.3928/1081-597X-20071101-01

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  32 in total

1.  Implantable collamer lenses after intracorneal ring segments for keratoconus.

Authors:  Alejandro Navas; Guillermo Tapia-Herrera; Martha Jaimes; Enrique O Graue-Hernández; Arturo Gomez-Bastar; Tito Ramirez-Luquín; Arturo Ramirez-Miranda
Journal:  Int Ophthalmol       Date:  2012-05-12       Impact factor: 2.031

2.  Phakic intraocular lenses outcomes and complications: Artisan vs Visian ICL.

Authors:  M A Hassaballa; T A Macky
Journal:  Eye (Lond)       Date:  2011-08-05       Impact factor: 3.775

3.  Comparison of postoperative optical quality according to the degree of decentering of V4c implantable collamer lens.

Authors:  Min Ji Park; Hye Min Jeon; Kyoung Heon Lee; Sang Youp Han
Journal:  Int J Ophthalmol       Date:  2017-04-18       Impact factor: 1.779

4.  Toric implantable collamer lens for moderate to high myopic astigmatism: 3-year follow-up.

Authors:  Esin Sogutlu Sari; David P Pinero; Anil Kubaloglu; Pinar Sorgun Evcili; Arif Koytak; Isil Kutlutürk; Yusuf Ozerturk
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-10-10       Impact factor: 3.117

5.  Outcomes and possible risk factors associated with axis alignment and rotational stability after implantation of the Toric implantable collamer lens for high myopic astigmatism.

Authors:  Xun-Lun Sheng; Wei-Ning Rong; Qin Jia; Ya-Ni Liu; Wen-Juan Zhuang; Qing Gu; Yan Sun; Bo Pan; De-Jun Zhu
Journal:  Int J Ophthalmol       Date:  2012-08-18       Impact factor: 1.779

6.  Comparison of patient outcomes after implantation of Visian toric implantable collamer lens and iris-fixated toric phakic intraocular lens.

Authors:  S Y Lee; H J Kwon; H S Ahn; K Y Seo; E K Kim; T-I Kim
Journal:  Eye (Lond)       Date:  2011-08-19       Impact factor: 3.775

7.  Clinical outcomes of posterior chamber toric phakic intraocular lens implantation for the correction of high myopic astigmatism in eyes with keratoconus: 6-month follow-up.

Authors:  Kazutaka Kamiya; Kimiya Shimizu; Hidenaga Kobashi; Mari Komatsu; Akio Nakamura; Tomoaki Nakamura; Kazuo Ichikawa
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-10-16       Impact factor: 3.117

Review 8.  [The basics of refractive lens exchange].

Authors:  T Kohnen; O K Klaproth
Journal:  Ophthalmologe       Date:  2008-11       Impact factor: 1.059

9.  Phakic intraocular lenses for the treatment of refractive errors: an evidence-based analysis.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2009-10-01

10.  Comparison of visual and refractive results of Toric Implantable Collamer Lens with bioptics for myopic astigmatism.

Authors:  J F Alfonso; C Lisa; L Fernández-Vega Cueto; P Fernandes; J M González-Méijome; R Montés Micó
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-09-23       Impact factor: 3.117

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.