Literature DB >> 21809012

Assessing qualitative changes in simulated periodontal ligament and alveolar bone using a non-contact electromagnetic vibration device.

Chiaki Kobayashi1, Makoto Hayashi, Masaru Yamaoka, Kazuhiro Hashimoto, Takeshi Kato, Norio Komori, Bunnai Ogiso.   

Abstract

The objective of this study is to investigate the ability of a non-contact electromagnetic vibration device to assess a simulated periodontal ligament and alveolar bone conditions in experimental tooth models by applying mechanical parameters (resonant frequency, elastic modulus, and coefficient of viscosity). The non-contact electromagnetic vibration device was made up of three components: vibrator, detector, and analyzer. The experimental tooth model consisted of a cylindrical rod made of polyacetal, a tissue conditioner for soft lining material, and urethane or urethane foam to simulate the tooth, periodontal ligament, and alveolar bone, respectively. The tissue conditioner was prepared by mixing various volumes of liquid with powder. Periotest values (PTVs) were also measured under the same conditions as those of the non-contact electromagnetic vibration device. All of the mechanical parameters derived from the non-contact electromagnetic vibration device significantly decreased as the proportion of liquid increased. Values for the three parameters of the urethane models were significantly larger than those of the urethane foam models. In contrast, PTVs increased significantly as the proportion of liquid increased; however, no significant difference was observed between the urethane and urethane foam models. The non-contact electromagnetic vibration device may be capable of evaluating not only periodontal ligament conditions but also bone quality. Mechanical parameters may be useful for assessing qualitative changes in the periodontal ligament and alveolar bone.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21809012     DOI: 10.1007/s00784-011-0597-9

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  29 in total

1.  Tissue banking of bone allografts used in periodontal regeneration.

Authors: 
Journal:  J Periodontol       Date:  2001-06       Impact factor: 6.993

Review 2.  Tissue conditioning materials as functional impression materials.

Authors:  Satinder Chander; Mark Hill; Derek Moore; Leean Morrow
Journal:  Eur J Prosthodont Restor Dent       Date:  2007-06

3.  Measuring tooth mobility with a no-contact vibration device.

Authors:  M Yamane; M Yamaoka; M Hayashi; I Furutoyo; N Komori; B Ogiso
Journal:  J Periodontal Res       Date:  2008-02       Impact factor: 4.419

Review 4.  Does periodontal tissue regeneration really work?

Authors:  Dieter D Bosshardt; Anton Sculean
Journal:  Periodontol 2000       Date:  2009       Impact factor: 7.589

5.  Panoramic-based mandibular indices in relation to mandibular bone mineral density and skeletal status assessed by dual energy X-ray absorptiometry and quantitative ultrasound.

Authors:  B Drozdzowska; W Pluskiewicz; B Tarnawska
Journal:  Dentomaxillofac Radiol       Date:  2002-11       Impact factor: 2.419

6.  Comparison between the Klemetti index and heel DXA BMD measurements in the diagnosis of reduced skeletal bone mineral density in the elderly.

Authors:  Anders Halling; G Rutger Persson; Johan Berglund; Owe Johansson; Stefan Renvert
Journal:  Osteoporos Int       Date:  2004-12-17       Impact factor: 4.507

7.  Development of ankylosis in permanent incisors following delayed replantation and severe intrusion.

Authors:  Karen M Campbell; Michael J Casas; David J Kenny
Journal:  Dent Traumatol       Date:  2007-06       Impact factor: 3.333

8.  The Periotest in traumatology. Part I. Does it have the properties necessary for use as a clinical device and can the measurements be interpreted?

Authors:  Mary Andresen; Iain Mackie; Helen Worthington
Journal:  Dent Traumatol       Date:  2003-08       Impact factor: 3.333

9.  Mandibular radiomorphometric indices in the diagnosis of reduced skeletal bone mineral density.

Authors:  H Devlin; K Horner
Journal:  Osteoporos Int       Date:  2002-05       Impact factor: 4.507

10.  Assessment of the periotest device in baseline mobility measurements of craniofacial implants.

Authors:  K Derhami; J F Wolfaardt; G Faulkner; M Grace
Journal:  Int J Oral Maxillofac Implants       Date:  1995 Mar-Apr       Impact factor: 2.804

View more
  2 in total

1.  Evaluation of Qualitative Changes in Simulated Periodontal Ligament and Alveolar Bone Using a Noncontact Electromagnetic Vibration Device with a Laser Displacement Sensor.

Authors:  Hiroshi Kobayashi; Makoto Hayashi; Masaru Yamaoka; Takuya Yasukawa; Haruna Ibi; Bunnai Ogiso
Journal:  Biomed Res Int       Date:  2016-05-04       Impact factor: 3.411

2.  Damping ratio analysis of tooth stability under various simulated degrees of vertical alveolar bone loss and different root types.

Authors:  Kuo-Ning Ho; Sheng-Yang Lee; Haw-Ming Huang
Journal:  Biomed Eng Online       Date:  2017-08-03       Impact factor: 2.819

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.