Literature DB >> 15179865

Feasibility of using orthogonal fluoroscopic images to measure in vivo joint kinematics.

Guoan Li1, Thomas H Wuerz, Louis E DeFrate.   

Abstract

Accurately determining in vivo knee kinematics is still a challenge in biomedical engineering. This paper presents an imaging technique using two orthogonal images to measure 6 degree-of-freedom (DOF) knee kinematics during weight-bearing flexion. Using this technique, orthogonal images of the knee were captured using a 3-D fluoroscope at different flexion angles during weight-bearing flexion. The two orthogonal images uniquely characterized the knee position at the specific flexion angle. A virtual fluoroscope was then created in solid modeling software and was used to reproduce the relative positions of the orthogonal images and X-ray sources of the 3-D fluoroscope during the actual imaging procedure. Two virtual cameras in the software were used to represent the X-ray sources. The 3-D computer model of the knee was then introduced into the virtual fluoroscope and was projected onto the orthogonal images by the two virtual cameras. By matching the projections of the knee model to the orthogonal images of the knee obtained during weight-bearing flexion, the knee kinematics in 6 DOF were determined. Using regularly shaped objects with known positions and orientations, this technique was shown to have an accuracy of 0.1 mm and 0.1 deg in determining the positions and orientations of the objects, respectively.

Mesh:

Year:  2004        PMID: 15179865     DOI: 10.1115/1.1691448

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  55 in total

1.  Validation of a new model-based tracking technique for measuring three-dimensional, in vivo glenohumeral joint kinematics.

Authors:  Michael J Bey; Roger Zauel; Stephanie K Brock; Scott Tashman
Journal:  J Biomech Eng       Date:  2006-08       Impact factor: 2.097

2.  The biomechanical function of the patellar tendon during in-vivo weight-bearing flexion.

Authors:  Louis E Defrate; Kyung Wook Nha; Ramprasad Papannagari; Jeremy M Moses; Thomas J Gill; Guoan Li
Journal:  J Biomech       Date:  2006-10-27       Impact factor: 2.712

3.  Physiological sagittal plane patellar kinematics during dynamic deep knee flexion.

Authors:  Satoshi Hamai; Nicholas J Dunbar; Taka-aki Moro-oka; Hiromasa Miura; Yukihide Iwamoto; Scott A Banks
Journal:  Int Orthop       Date:  2013-06-19       Impact factor: 3.075

4.  An In Vivo Prediction of Anisometry and Strain in Anterior Cruciate Ligament Reconstruction - A Combined Magnetic Resonance and Dual Fluoroscopic Imaging Analysis.

Authors:  Willem A Kernkamp; Nathan H Varady; Jing-Sheng Li; Tsung-Yuan Tsai; Peter D Asnis; Ewoud R A van Arkel; Rob G H H Nelissen; Thomas J Gill; Samuel K Van de Velde; Guoan Li
Journal:  Arthroscopy       Date:  2018-03-01       Impact factor: 4.772

5.  Validation of three-dimensional model-based tibio-femoral tracking during running.

Authors:  William Anderst; Roger Zauel; Jennifer Bishop; Erinn Demps; Scott Tashman
Journal:  Med Eng Phys       Date:  2008-04-23       Impact factor: 2.242

6.  In vivo Kinematics of the Knee after a Posterior Cruciate-Substituting Total Knee Arthroplasty: A Comparison between Caucasian and South Korean Patients.

Authors:  Ji-Hoon Bae; Ali Hosseini; Kyung-Wook Nha; Sang-Eun Park; Tsung Yuan Tsai; Young-Min Kwon; Guoan Li
Journal:  Knee Surg Relat Res       Date:  2016-06-01

7.  In Vivo Anterolateral Ligament Length Change in the Healthy Knee During Functional Activities-A Combined Magnetic Resonance and Dual Fluoroscopic Imaging Analysis.

Authors:  Willem A Kernkamp; Samuel K Van de Velde; Ali Hosseini; Tsung-Yuan Tsai; Jing-Sheng Li; Ewoud R A van Arkel; Guoan Li
Journal:  Arthroscopy       Date:  2016-09-20       Impact factor: 4.772

8.  High-speed X-ray video demonstrates significant skin movement errors with standard optical kinematics during rat locomotion.

Authors:  Jay M Bauman; Young-Hui Chang
Journal:  J Neurosci Methods       Date:  2009-11-10       Impact factor: 2.390

9.  Evaluation of kinematics of anterior cruciate ligament-deficient knees with use of advanced imaging techniques, three-dimensional modeling techniques, and robotics.

Authors:  Samuel K Van de Velde; Thomas J Gill; Guoan Li
Journal:  J Bone Joint Surg Am       Date:  2009-02       Impact factor: 5.284

10.  New fluoroscopic imaging technique for investigation of 6DOF knee kinematics during treadmill gait.

Authors:  Guoan Li; Michal Kozanek; Ali Hosseini; Fang Liu; Samuel K Van de Velde; Harry E Rubash
Journal:  J Orthop Surg Res       Date:  2009-03-13       Impact factor: 2.359

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.