The use of optical coherence tomography in intraoperative ophthalmic imaging.

Paul Hahn1, Justin Migacz, Rachelle O'Connell, Ramiro S Maldonado, Joseph A Izatt, Cynthia A Toth.   

Abstract

Optical coherence tomography (OCT) has transformed diagnostic ophthalmic imaging but until recently has been limited to the clinic setting. The development of spectral-domain OCT (SD-OCT), with its improved speed and resolution, along with the development of a handheld OCT scanner, enabled portable imaging of patients unable to sit in a conventional tabletop scanner. This handheld SD-OCT unit has proven useful in examinations under anesthesia and, more recently, in intraoperative imaging of preoperative and postoperative manipulations. Recently, several groups have pioneered the development of novel OCT modalities, such as microscope-mounted OCT systems. Although still immature, the development of these systems is directed toward real-time imaging of surgical maneuvers in the intraoperative setting. This article reviews intraoperative imaging of the posterior and anterior segment using the handheld SD-OCT and recent advances toward real-time microscope-mounted intrasurgical imaging. Copyright 2011, SLACK Incorporated.

Entities:  

Mesh:

Year:  2011        PMID: 21790116      PMCID: PMC3510671          DOI: 10.3928/15428877-20110627-08

Source DB:  PubMed          Journal:  Ophthalmic Surg Lasers Imaging        ISSN: 1542-8877


  51 in total

1.  Real-time optical coherence tomography of the anterior segment at 1310 nm.

Authors:  S Radhakrishnan; A M Rollins; J E Roth; S Yazdanfar; V Westphal; D S Bardenstein; J A Izatt
Journal:  Arch Ophthalmol       Date:  2001-08

2.  Optical coherence tomography.

Authors:  D Huang; E A Swanson; C P Lin; J S Schuman; W G Stinson; W Chang; M R Hee; T Flotte; K Gregory; C A Puliafito
Journal:  Science       Date:  1991-11-22       Impact factor: 47.728

3.  Features of macular hole closure in the early postoperative period using optical coherence tomography.

Authors:  J M Jumper; R P Gallemore; B W McCuen; C A Toth
Journal:  Retina       Date:  2000       Impact factor: 4.256

Review 4.  Optical coherence tomography: a new tool for glaucoma diagnosis.

Authors:  J S Schuman; M R Hee; A V Arya; T Pedut-Kloizman; C A Puliafito; J G Fujimoto; E A Swanson
Journal:  Curr Opin Ophthalmol       Date:  1995-04       Impact factor: 3.761

5.  Optical coherence tomography of macular holes.

Authors:  M R Hee; C A Puliafito; C Wong; J S Duker; E Reichel; J S Schuman; E A Swanson; J G Fujimoto
Journal:  Ophthalmology       Date:  1995-05       Impact factor: 12.079

6.  Diagnosis of vitreoretinal adhesions in macular disease with optical coherence tomography.

Authors:  R P Gallemore; J M Jumper; B W McCuen; G J Jaffe; E A Postel; C A Toth
Journal:  Retina       Date:  2000       Impact factor: 4.256

7.  Intraoperative microscope-mounted spectral domain optical coherence tomography for evaluation of retinal anatomy during macular surgery.

Authors:  Robin Ray; David E Barañano; Jorge A Fortun; Bryan J Schwent; Blaine E Cribbs; Chris S Bergstrom; G Baker Hubbard; Sunil K Srivastava
Journal:  Ophthalmology       Date:  2011-09-09       Impact factor: 12.079

8.  Foveal hypoplasia in oculocutaneous albinism demonstrated by optical coherence tomography.

Authors:  Carsten H Meyer; Deborah J Lapolice; Sharon F Freedman
Journal:  Am J Ophthalmol       Date:  2002-03       Impact factor: 5.258

9.  Optical coherence tomography in children: analysis of 44 eyes with intraocular tumors and simulating conditions.

Authors:  Carol L Shields; Arman Mashayekhi; Caesar Kyle Luo; Miguel A Materin; Jerry A Shields
Journal:  J Pediatr Ophthalmol Strabismus       Date:  2004 Nov-Dec       Impact factor: 1.402

10.  Micrometer-scale resolution imaging of the anterior eye in vivo with optical coherence tomography.

Authors:  J A Izatt; M R Hee; E A Swanson; C P Lin; D Huang; J S Schuman; C A Puliafito; J G Fujimoto
Journal:  Arch Ophthalmol       Date:  1994-12
View more
  34 in total

1.  Automated stereo vision instrument tracking for intraoperative OCT guided anterior segment ophthalmic surgical maneuvers.

Authors:  Mohamed T El-Haddad; Yuankai K Tao
Journal:  Biomed Opt Express       Date:  2015-07-23       Impact factor: 3.732

Review 2.  Intraoperative optical coherence tomography: past, present, and future.

Authors:  J P Ehlers
Journal:  Eye (Lond)       Date:  2015-12-18       Impact factor: 3.775

3.  Miniature real-time intraoperative forward-imaging optical coherence tomography probe.

Authors:  Karen M Joos; Jin-Hui Shen
Journal:  Biomed Opt Express       Date:  2013-07-16       Impact factor: 3.732

Review 4.  Clinical utility of intraoperative optical coherence tomography.

Authors:  Mehnaz Khan; Justis P Ehlers
Journal:  Curr Opin Ophthalmol       Date:  2016-05       Impact factor: 3.761

5.  Intraoperative optical coherence tomography in macula involving rhegmatogenous retinal detachment repair with pars plana vitrectomy and perfluoron.

Authors:  O Toygar; C D Riemann
Journal:  Eye (Lond)       Date:  2015-12-11       Impact factor: 3.775

6.  Factors associated with persistent subfoveal fluid and complete macular hole closure in the PIONEER study.

Authors:  Justis P Ehlers; Yuji Itoh; Lucy T Xu; Peter K Kaiser; Rishi P Singh; Sunil K Srivastava
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-12-18       Impact factor: 4.799

7.  High definition live 3D-OCT in vivo: design and evaluation of a 4D OCT engine with 1 GVoxel/s.

Authors:  Wolfgang Wieser; Wolfgang Draxinger; Thomas Klein; Sebastian Karpf; Tom Pfeiffer; Robert Huber
Journal:  Biomed Opt Express       Date:  2014-08-06       Impact factor: 3.732

8.  Evaluation of microsurgical tasks with OCT-guided and/or robot-assisted ophthalmic forceps.

Authors:  Haoran Yu; Jin-Hui Shen; Rohan J Shah; Nabil Simaan; Karen M Joos
Journal:  Biomed Opt Express       Date:  2015-01-09       Impact factor: 3.732

9.  Intraoperative optical coherence tomography-compatible surgical instruments for real-time image-guided ophthalmic surgery.

Authors:  Justis P Ehlers; Atsuro Uchida; Sunil K Srivastava
Journal:  Br J Ophthalmol       Date:  2017-07-20       Impact factor: 4.638

10.  Preclinical evaluation and intraoperative human retinal imaging with a high-resolution microscope-integrated spectral domain optical coherence tomography device.

Authors:  Paul Hahn; Justin Migacz; Rachelle O'Donnell; Shelley Day; Annie Lee; Phoebe Lin; Robin Vann; Anthony Kuo; Sharon Fekrat; Prithvi Mruthyunjaya; Eric A Postel; Joseph A Izatt; Cynthia A Toth
Journal:  Retina       Date:  2013 Jul-Aug       Impact factor: 4.256

View more