Literature DB >> 28729372

Intraoperative optical coherence tomography-compatible surgical instruments for real-time image-guided ophthalmic surgery.

Justis P Ehlers1, Atsuro Uchida1, Sunil K Srivastava1.   

Abstract

Intraoperative optical coherence tomography (OCT) is a potentially transformational technology that is now commercially available to ophthalmic surgeons. Currently, the use of the technology is primarily limited to a 'stop and image' approach due to the lack of OCT compatibility with surgical instrumentation. In this report, we describe multiple OCT-compatible surgical instruments that were developed for various surgical needs, based on previous evaluation of potential surgical materials for optical features and physical properties. OCT-compatible instrumentation included two membrane scrapers, a surgical pick and vitreoretinal forceps. Imaging during in vitro and ex vivo-simulated surgical procedures demonstrated excellent visualisation of the instrument tip and of the tissue-instrument interaction. These OCT-compatible instruments may be a key component to the feasibility of real-time image-guided surgery with intraoperative OCT. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

Entities:  

Keywords:  imaging; retina; treatment surgery

Mesh:

Year:  2017        PMID: 28729372      PMCID: PMC5675732          DOI: 10.1136/bjophthalmol-2017-310530

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  10 in total

1.  Feasibility of intrasurgical spectral-domain optical coherence tomography.

Authors:  Susanne Binder; Christiane I Falkner-Radler; Christoph Hauger; Holger Matz; Carl Glittenberg
Journal:  Retina       Date:  2011 Jul-Aug       Impact factor: 4.256

2.  Integration of a spectral domain optical coherence tomography system into a surgical microscope for intraoperative imaging.

Authors:  Justis P Ehlers; Yuankai K Tao; Sina Farsiu; Ramiro Maldonado; Joseph A Izatt; Cynthia A Toth
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-05-16       Impact factor: 4.799

Review 3.  The value of intraoperative optical coherence tomography imaging in vitreoretinal surgery.

Authors:  Justis P Ehlers; Yuankai K Tao; Sunil K Srivastava
Journal:  Curr Opin Ophthalmol       Date:  2014-05       Impact factor: 3.761

Review 4.  The use of optical coherence tomography in intraoperative ophthalmic imaging.

Authors:  Paul Hahn; Justin Migacz; Rachelle O'Connell; Ramiro S Maldonado; Joseph A Izatt; Cynthia A Toth
Journal:  Ophthalmic Surg Lasers Imaging       Date:  2011-07

5.  Intraoperative microscope-mounted spectral domain optical coherence tomography for evaluation of retinal anatomy during macular surgery.

Authors:  Robin Ray; David E Barañano; Jorge A Fortun; Bryan J Schwent; Blaine E Cribbs; Chris S Bergstrom; G Baker Hubbard; Sunil K Srivastava
Journal:  Ophthalmology       Date:  2011-09-09       Impact factor: 12.079

6.  Intraoperative SD-OCT in macular surgery.

Authors:  Francesco Pichi; Micol Alkabes; Paolo Nucci; Antonio P Ciardella
Journal:  Ophthalmic Surg Lasers Imaging       Date:  2012 Nov-Dec

7.  Determination of feasibility and utility of microscope-integrated optical coherence tomography during ophthalmic surgery: the DISCOVER Study RESCAN Results.

Authors:  Justis P Ehlers; Jeff Goshe; William J Dupps; Peter K Kaiser; Rishi P Singh; Richard Gans; Jonathan Eisengart; Sunil K Srivastava
Journal:  JAMA Ophthalmol       Date:  2015-10       Impact factor: 7.389

8.  The Prospective Intraoperative and Perioperative Ophthalmic ImagiNg with Optical CoherEncE TomogRaphy (PIONEER) Study: 2-year results.

Authors:  Justis P Ehlers; William J Dupps; Peter K Kaiser; Jeff Goshe; Rishi P Singh; Daniel Petkovsek; Sunil K Srivastava
Journal:  Am J Ophthalmol       Date:  2014-07-29       Impact factor: 5.258

9.  Visualization of real-time intraoperative maneuvers with a microscope-mounted spectral domain optical coherence tomography system.

Authors:  Justis P Ehlers; Yuankai K Tao; Sina Farsiu; Ramiro Maldonado; Joseph A Izatt; Cynthia A Toth
Journal:  Retina       Date:  2013-01       Impact factor: 4.256

10.  Integrative advances for OCT-guided ophthalmic surgery and intraoperative OCT: microscope integration, surgical instrumentation, and heads-up display surgeon feedback.

Authors:  Justis P Ehlers; Sunil K Srivastava; Daniel Feiler; Amanda I Noonan; Andrew M Rollins; Yuankai K Tao
Journal:  PLoS One       Date:  2014-08-20       Impact factor: 3.240

  10 in total
  4 in total

1.  Processing-Aware Real-Time Rendering for Optimized Tissue Visualization in Intraoperative 4D OCT.

Authors:  Jakob Weiss; Michael Sommersperger; Ali Nasseri; Abouzar Eslami; Ulrich Eck; Nassir Navab
Journal:  Med Image Comput Comput Assist Interv       Date:  2020-09-29

2.  The DISCOVER Study 3-Year Results: Feasibility and Usefulness of Microscope-Integrated Intraoperative OCT during Ophthalmic Surgery.

Authors:  Justis P Ehlers; Yasha S Modi; Paula E Pecen; Jeff Goshe; William J Dupps; Aleksandra Rachitskaya; Sumit Sharma; Alex Yuan; Rishi Singh; Peter K Kaiser; Jamie L Reese; Carmen Calabrise; Allison Watts; Sunil K Srivastava
Journal:  Ophthalmology       Date:  2018-03-02       Impact factor: 12.079

Review 3.  Intra-operative optical coherence tomography in glaucoma surgery-a systematic review.

Authors:  Bryan C H Ang; Sheng Yang Lim; Syril Dorairaj
Journal:  Eye (Lond)       Date:  2019-11-26       Impact factor: 3.775

Review 4.  A Review of Robotic and OCT-Aided Systems for Vitreoretinal Surgery.

Authors:  Elan Z Ahronovich; Nabil Simaan; Karen M Joos
Journal:  Adv Ther       Date:  2021-04-03       Impact factor: 3.845

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.