CT substitute derived from MRI sequences with ultrashort echo time.

Adam Johansson1, Mikael Karlsson, Tufve Nyholm.   

Abstract

PURPOSE: Methods for deriving computed tomography (CT) equivalent information from MRI are needed for attenuation correction in PET/MRI applications, as well as for patient positioning and dose planning in MRI based radiation therapy workflows. This study presents a method for generating a drop in substitute for a CT image from a set of magnetic resonance (MR)images.
METHODS: A Gaussian mixture regression model was used to link the voxel values in CT images to the voxel values in images from three MRI sequences: one T2 weighted 3D spin echo based sequence and two dual echo ultrashort echo time MRI sequences with different echo times and flip angles. The method used a training set of matched MR and CT data that after training was able to predict a substitute CT (s-CT) based entirely on the MR information for a new patient. Method validation was achieved using datasets covering the heads of five patients and applying leave-one-out cross-validation (LOOCV). During LOOCV, the model was estimated from the MR and CT data of four patients (training set) and applied to the MR data of the remaining patient (validation set) to generate an s-CT image. This procedure was repeated for all five training and validation data combinations.
RESULTS: The mean absolute error for the CT number in the s-CT images was 137 HU. No large differences in method accuracy were noted for the different patients, indicating a robust method. The largest errors in the s-CT images were found at air-tissue and bone-tissue interfaces. The model accurately discriminated between air and bone, as well as between soft tissues and nonsoft tissues.
CONCLUSIONS: The s-CT method has the potential to provide an accurate estimation of CT information without risk of geometrical inaccuracies as the model is voxel based. Therefore, s-CT images could be well suited as alternatives to CT images for dose planning in radiotherapy and attenuation correction in PET/MRI.

Entities:  

Mesh:

Year:  2011        PMID: 21776807     DOI: 10.1118/1.3578928

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  104 in total

Review 1.  Clinical and research applications of simultaneous positron emission tomography and MRI.

Authors:  F Fraioli; S Punwani
Journal:  Br J Radiol       Date:  2013-11-14       Impact factor: 3.039

2.  mDixon-Based Synthetic CT Generation for PET Attenuation Correction on Abdomen and Pelvis Jointly Using Transfer Fuzzy Clustering and Active Learning-Based Classification.

Authors:  Pengjiang Qian; Yangyang Chen; Jung-Wen Kuo; Yu-Dong Zhang; Yizhang Jiang; Kaifa Zhao; Rose Al Helo; Harry Friel; Atallah Baydoun; Feifei Zhou; Jin Uk Heo; Norbert Avril; Karin Herrmann; Rodney Ellis; Bryan Traughber; Robert S Jones; Shitong Wang; Kuan-Hao Su; Raymond F Muzic
Journal:  IEEE Trans Med Imaging       Date:  2019-08-16       Impact factor: 10.048

Review 3.  Clinical oncologic applications of PET/MRI: a new horizon.

Authors:  Sasan Partovi; Andres Kohan; Christian Rubbert; Jose Luis Vercher-Conejero; Chiara Gaeta; Roger Yuh; Lisa Zipp; Karin A Herrmann; Mark R Robbin; Zhenghong Lee; Raymond F Muzic; Peter Faulhaber; Pablo R Ros
Journal:  Am J Nucl Med Mol Imaging       Date:  2014-03-20

4.  Automatic correction of dental artifacts in PET/MRI.

Authors:  Claes N Ladefoged; Flemming L Andersen; Sune H Keller; Thomas Beyer; Ian Law; Liselotte Højgaard; Sune Darkner; Francois Lauze
Journal:  J Med Imaging (Bellingham)       Date:  2015-06-09

Review 5.  MRI-only treatment planning: benefits and challenges.

Authors:  Amir M Owrangi; Peter B Greer; Carri K Glide-Hurst
Journal:  Phys Med Biol       Date:  2018-02-26       Impact factor: 3.609

6.  Investigation of a method for generating synthetic CT models from MRI scans of the head and neck for radiation therapy.

Authors:  Shu-Hui Hsu; Yue Cao; Ke Huang; Mary Feng; James M Balter
Journal:  Phys Med Biol       Date:  2013-11-11       Impact factor: 3.609

7.  Improvement of attenuation correction in time-of-flight PET/MR imaging with a positron-emitting source.

Authors:  Pieter Mollet; Vincent Keereman; Jason Bini; David Izquierdo-Garcia; Zahi A Fayad; Stefaan Vandenberghe
Journal:  J Nucl Med       Date:  2014-01-16       Impact factor: 10.057

8.  On the accuracy and reproducibility of a novel probabilistic atlas-based generation for calculation of head attenuation maps on integrated PET/MR scanners.

Authors:  Kevin T Chen; David Izquierdo-Garcia; Clare B Poynton; Daniel B Chonde; Ciprian Catana
Journal:  Eur J Nucl Med Mol Imaging       Date:  2016-08-29       Impact factor: 9.236

9.  Generating synthetic CTs from magnetic resonance images using generative adversarial networks.

Authors:  Hajar Emami; Ming Dong; Siamak P Nejad-Davarani; Carri K Glide-Hurst
Journal:  Med Phys       Date:  2018-06-14       Impact factor: 4.071

Review 10.  MR Imaging-Guided Attenuation Correction of PET Data in PET/MR Imaging.

Authors:  David Izquierdo-Garcia; Ciprian Catana
Journal:  PET Clin       Date:  2016-01-26