Literature DB >> 21769688

Biocompatibility and durability of Teflon-coated platinum-iridium wires implanted in the vitreous cavity.

Kentaro Nishida1, Hirokazu Sakaguchi, Ping Xie, Yasuo Terasawa, Motoki Ozawa, Motohiro Kamei, Kohji Nishida.   

Abstract

Teflon-coated platinum-iridium wires are placed in the vitreous as electrodes in artificial vision systems. The purpose of this study was to determine whether these wires have toxicity in the vitreous cavity, and to examine the durability of their coating when grasped by forceps. Rabbits were implanted with platinum-iridium wires that were 50 μm in diameter and coated with Teflon to a total diameter of 68 or 100 μm. To examine the biocompatibility, electroretinograms (ERGs) and fluorescein angiography (FA) were performed before and 1 week, 1, 3, and 6 months after the implantation of the electrode. After 6 months, the eyes were histologically examined with light microscopy. To check the durability, the surface of a coated wire was examined with scanning electron microscopy after grasping with different types of forceps. At all times after the implantation the amplitudes and implicit times of the ERGs recorded were not significantly different from those recorded before the implantation (P > 0.05). FA showed no notable change during the follow-up periods. Histological studies showed that the retinas were intact after 6 months of implantation. There was no damage to the Teflon-coated wire after grasping the wire with forceps with silicon-coated tips, while surface damage of the Teflon that did not extend to the platinum-iridium wire was found when grasped by vitreoretinal forceps. We conclude that Teflon-coated platinum-iridium wire is highly biocompatible in the vitreous for at least 6 months. Wires should be handled with vitreoretinal forceps with silicone-coated tips in order to avoid causing damage during wire manipulation.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21769688     DOI: 10.1007/s10047-011-0591-7

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  24 in total

1.  Electrophysiological studies of the feasibility of suprachoroidal-transretinal stimulation for artificial vision in normal and RCS rats.

Authors:  Hiroyuki Kanda; Takeshi Morimoto; Takashi Fujikado; Yasuo Tano; Yutaka Fukuda; Hajime Sawai
Journal:  Invest Ophthalmol Vis Sci       Date:  2004-02       Impact factor: 4.799

2.  The subretinal implant: can microphotodiode arrays replace degenerated retinal photoreceptors to restore vision?

Authors:  Eberhart Zrenner
Journal:  Ophthalmologica       Date:  2002       Impact factor: 3.250

3.  Electrophysiological and histological studies of chronically implanted intrapapillary microelectrodes in rabbit eyes.

Authors:  Xiaoyun Fang; Hirokazu Sakaguchi; Takashi Fujikado; Makoto Osanai; Yasushi Ikuno; Motohiro Kamei; Masahito Ohji; Tetsuya Yagi; Yasuo Tano
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2005-08-04       Impact factor: 3.117

4.  Intraorbital optic nerve stimulation with penetrating electrodes: in vivo electrophysiology study in rabbits.

Authors:  Liming Li; Pengjia Cao; Mingjie Sun; Xinyu Chai; Kaijie Wu; Xun Xu; Xiaoxin Li; Qiushi Ren
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2008-11-07       Impact factor: 3.117

5.  Evoked cortical potentials after electrical stimulation of the inner retina in rabbits.

Authors:  P Walter; K Heimann
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2000-04       Impact factor: 3.117

6.  A new vascular prosthesis for a small caliber artery.

Authors:  H Matsumoto; T Hasegawa; K Fuse; M Yamamoto; M Saigusa
Journal:  Surgery       Date:  1973-10       Impact factor: 3.982

7.  Expanded polytetrafluoroethylene reinforcement material in glaucoma drain surgery.

Authors:  T Jacob; O J LaCour; C F Burgoyne; P K LaFleur; E Duzman
Journal:  J Glaucoma       Date:  2001-04       Impact factor: 2.503

8.  Transretinal electrical stimulation by an intrascleral multichannel electrode array in rabbit eyes.

Authors:  Kazuaki Nakauchi; Takashi Fujikado; Hiroyuki Kanda; Takeshi Morimoto; Jun S Choi; Yasushi Ikuno; Hirokazu Sakaguchi; Motohiro Kamei; Masahito Ohji; Tohru Yagi; Shigeru Nishimura; Hajime Sawai; Yutaka Fukuda; Yasuo Tano
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2004-12-07       Impact factor: 3.117

9.  Visual sensations produced by optic nerve stimulation using an implanted self-sizing spiral cuff electrode.

Authors:  C Veraart; C Raftopoulos; J T Mortimer; J Delbeke; D Pins; G Michaux; A Vanlierde; S Parrini; M C Wanet-Defalque
Journal:  Brain Res       Date:  1998-11-30       Impact factor: 3.252

10.  Artificial vision by direct optic nerve electrode (AV-DONE) implantation in a blind patient with retinitis pigmentosa.

Authors:  Hirokazu Sakaguchi; Motohiro Kamei; Takashi Fujikado; Eiji Yonezawa; Motoki Ozawa; Carmen Cecilia-Gonzalez; Orlando Ustariz-Gonzalez; Hugo Quiroz-Mercado; Yasuo Tano
Journal:  J Artif Organs       Date:  2009-09-19       Impact factor: 1.731

View more
  2 in total

Review 1.  Journal of Artificial Organs 2011: the year in review.

Authors:  Y Sawa; E Tatsumi; A Funakubo; T Horiuchi; K Iwasaki; A Kishida; T Masuzawa; K Matsuda; A Myoui; M Nishimura; T Nishimura; S Tokunaga; Y Tomizawa; T Tomo; T Tsukiya; T Yamaoka
Journal:  J Artif Organs       Date:  2012-02-29       Impact factor: 1.731

2.  Implantation of a newly developed direct optic nerve electrode device for artificial vision in rabbits.

Authors:  Hirokazu Sakaguchi; Motohiro Kamei; Kentaro Nishida; Yasuo Terasawa; Takashi Fujikado; Motoki Ozawa; Kohji Nishida
Journal:  J Artif Organs       Date:  2012-04-07       Impact factor: 1.731

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.