Literature DB >> 11316093

Expanded polytetrafluoroethylene reinforcement material in glaucoma drain surgery.

T Jacob1, O J LaCour, C F Burgoyne, P K LaFleur, E Duzman.   

Abstract

PURPOSE: To determine whether a synthetic material, expanded polytetrafluoroethylene (E-PTFE), can be used successfully as a reinforcement material over the tubes of glaucoma drainage implants.
METHODS: Patches of E-PTFE were sutured over the tubes of Baerveldt glaucoma drains implanted in the eyes of New Zealand white rabbits. Two material thicknesses were tested: 0.5 mm in four eyes and 0.25 mm in five eyes. Rabbit donor scleral patches were used in five eyes as the control. Total ocular health and intraocular pressure were monitored every 2 weeks after the procedure. Six months after implantation, the eyes were harvested and analyzed histologically.
RESULTS: Two of the four eyes that received 0.5-mm thick E-PTFE patches showed some conjunctival melting over the anterior corners of the material close to the limbus. All five eyes that received 0.25-mm thick E-PTFE patches showed a healthy cellular wound healing response and no conjunctival melting. Cellular infiltration and collagen deposition in the E-PTFE materials showed integration of the patch material into the surrounding tissue. In the control eyes, marked thinning and resorption of the donor sclera immediately above the drainage tube was noted.
CONCLUSION: Thin (0.25 mm) E-PTFE patches were well tolerated in all rabbit eyes tested. Thin E-PTFE should be investigated further as a functional alternative to donor sclera for reinforcement in glaucoma drain surgery.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11316093     DOI: 10.1097/00061198-200104000-00008

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  6 in total

1.  Clinical experience of e-PTFE membrane implant surgery for refractory glaucoma.

Authors:  C Kim; Y Kim; S Choi; S Lee; B Ahn
Journal:  Br J Ophthalmol       Date:  2003-01       Impact factor: 4.638

2.  Biocompatibility and durability of Teflon-coated platinum-iridium wires implanted in the vitreous cavity.

Authors:  Kentaro Nishida; Hirokazu Sakaguchi; Ping Xie; Yasuo Terasawa; Motoki Ozawa; Motohiro Kamei; Kohji Nishida
Journal:  J Artif Organs       Date:  2011-07-19       Impact factor: 1.731

3.  A novel application of amniotic membrane in patients with bullous keratopathy.

Authors:  Hyeon Il Lee; Sang Woo Ha; Jae Chan Kim
Journal:  J Korean Med Sci       Date:  2006-04       Impact factor: 2.153

4.  Tube Exposure Repair.

Authors:  Stirbu Oana; Jorge Vila
Journal:  J Curr Glaucoma Pract       Date:  2012-10-16

Review 5.  Device-modified trabeculectomy for glaucoma.

Authors:  Xue Wang; Rabeea Khan; Anne Coleman
Journal:  Cochrane Database Syst Rev       Date:  2015-12-01

6.  A new glaucoma drainage implant with the use of Polytetrafluoroethylene (PTFE). A pilot study.

Authors:  Azadeh Samaeili; Saeed Rahmani; Kiana Hassanpour; Aidin Meshksar; Iman Ansari; Sasha Afsar-Aski; Bahram Einollahi; Mohammad Pakravan
Journal:  Rom J Ophthalmol       Date:  2021 Apr-Jun
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.