Performance Trade-Off Analysis Comparing Different Front-End Configurations for a Digital X-ray Imager.

Andrew Kuhls-Gilcrist1, Amit Jain, Daniel R Bednarek, Stephen Rudin.   

Abstract

Performance of indirect digital x-ray imagers is typically limited by the front-end components. Present x-ray-to-light converting phosphors significantly reduce detector resolution due to stochastic blurring and k-fluorescent x-ray reabsorption. Thinner phosphors improve resolution at the cost of lowering quantum detection efficiency (QDE) and increasing Swank noise. Magnifying fiber optic tapers (FOTs) are commonly used to increase the field-of-view of small sensor imagers, such as CMOS, CCD, or electron-multiplying CCD (EMCCD) based detectors, which results in a reduction in detector sensitivity and further reduces the MTF. We investigate performance trade-offs for different front-end configurations coupled to an EMCCD sensor with 8 μm pixels. Six different columnar structured CsI(Tl) scintillators with thicknesses of 100, 200, 350, 500, and 1000 μm type high-light (HL) and a 350 μm type high-resolution (HR) (Hamamatsu) and four different FOTs with magnification ratios (M) of 1, 2.5, 3.3, and 4 were studied using the RQA5 x-ray spectrum. The relative signal of the different scintillators largely followed the relative QDE, indicating their light output per absorbed x-ray was similar, with the type HR CsI emitting 57% of the type HL. The efficiency of the FOTs was inversely proportional to M(2) with the M = 1 FOT transmitting 87% of the incident light. At 5 (10) cycles/mm, the CsI MTF was 0.38 (0.22), 0.33 (0.17), 0.37 (0.19), 0.23 (0.09), 0.19 (0.08), and 0.09 (0.03) for the 100, 200, 350HR, 350, 500, and 1000 μm CsI, respectively and the FOT MTF was 0.89 (0.84), 0.80 (0.72), 0.70 (0.60), and 0.69 (0.37) for M = 1, 2.5, 3.3, and 4, respectively. The 1000, 500, and 350HR μm CsI had the highest DQE for low, medium, and high spatial frequency ranges of 0 to 1.6, 1.6 to 4.5, and 4.5 to 10 cycles/mm, respectively. Larger FOT M resulted in a reduction in DQE. Quantifying performance of different front-end configurations will enable optimal selection of components for task-specific designs.

Entities:  

Year:  2010        PMID: 21731411      PMCID: PMC3127232          DOI: 10.1109/NSSMIC.2010.5874235

Source DB:  PubMed          Journal:  IEEE Nucl Sci Symp Conf Rec (1997)        ISSN: 1095-7863


  7 in total

1.  A method for the determination of the two-dimensional MTF of digital radiography systems using only the noise response.

Authors:  Andrew Kuhls-Gilcrist; Daniel R Bednarek; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2010-03-23

2.  The Solid-State X-Ray Image Intensifier (SSXII): An EMCCD-Based X-Ray Detector.

Authors:  Andrew Kuhls-Gilcrist; Girijesh Yadava; Vikas Patel; Amit Jain; Daniel R Bednarek; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2008

3.  The Solid State X-ray Image Intensifier (SSXII) in Single Photon Counting (SPC) mode.

Authors:  Andrew Kuhls-Gilcrist; Amit Jain; Daniel R Bednarek; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2010-03-22

4.  Accurate MTF measurement in digital radiography using noise response.

Authors:  Andrew Kuhls-Gilcrist; Amit Jain; Daniel R Bednarek; Kenneth R Hoffmann; Stephen Rudin
Journal:  Med Phys       Date:  2010-02       Impact factor: 4.071

5.  Progress in electron-multiplying CCD (EMCCD) based, high-resolution, high-sensitivity x-ray detector for fluoroscopy and radiography.

Authors:  Andrew T Kuhls; Girijesh Yadava; Vikas Patel; Daniel R Bednarek; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2007

6.  X-ray imaging performance of structured cesium iodide scintillators.

Authors:  Wei Zhao; Goran Ristic; J A Rowlands
Journal:  Med Phys       Date:  2004-09       Impact factor: 4.071

7.  Component analysis of a new Solid State X-ray Image Intensifier (SSXII) using photon transfer and Instrumentation Noise Equivalent Exposure (INEE) measurements.

Authors:  Andrew Kuhls-Gilcrist; Daniel R Bednarek; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2009-01-01
  7 in total
  1 in total

1.  Evaluation of intracranial aneurysm coil embolization in phantoms and patients using a high-resolution Microangiographic Fluoroscope (MAF).

Authors:  Ciprian N Ionita; Amit Jain; Brendan Loughran; Swetadri Vasan S N; Daniel R Bednarek; Elad Levy; Adnan H Siddiqui; Kenneth V Snyder; L N Hopkins; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2012-03-02
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.